HS151DR Series Assemblies
•
40 amp AC output @ 40°C
•
Single or Dual Channel output
•
3 to 32 VDC input control voltage
•
DIN Rail mounted
•
uL, CSA, VDE, CE approved SSRs
PRODUCT SELECTION
Description 40 A 40 A 40 A
3-32 VDC Control HS151DR-D2450 HS151DR-HD6050 HS151DR-CC2450W3U
OUTPUT SPECIFICATIONS (1)
Description HS151DR-D2450 HS151DR-HD6050 HS151DR-CC2450W3U
Operating Voltage (47-63Hz) [Vrms] 24-280 48-660 24-280
Transient Overvoltage [Vpk] 600 1200 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 0.1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500
Maximum Load Current [Arms] 40 40 40
Minimum Load Current [Arms] 0.04 0.04 0.15
Maximum Surge Current (16.6ms) [Apk] 625 625 750
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.7 1.3
Maximum I²t for Fusing (8.3 msec) [A² sec] 1620 1620 2320
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
INPUT SPECIFICATIONS (1)
Description HS151DR-D2450 HS151DR-HD6050 HS151DR-CC2450W3U
Control Voltage Range 3-32 VDC 3-32 VDC 4-32 VDC
Minimum T urn -On Voltage 3.0 VDC 3.0 VDC 4.0 VDC
Minimum Tu rn -Of f Volta ge 1.0 VDC 1.0 VDC 1.0 VDC
Maximum Reverse Voltage 32 VDC 32 VDC 32 VDC
Typical Input Current 3.4 mA @ 5 VDC 2.0 mA (3) 10 mA @ 12 VDC
Nominal Input Impeadance 1500 Ohms (3) (3)
Maximum Turn-On Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle
GENERAL SPECIFICATIONS
Description HS151DR-Dxx50 HS151DR-CC2450W3U
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 4000 Vrms
Minimum Insulation Resistance (@ 500 V DC) 109 Ohms 109 Ohms
Maximum Capacitance, Input/Output 8 pF 10 pF
Ambient Operating Temperature Range -40 to 80˚C-40 to 80°C
Ambient Storage Temperature Range -40 to 125˚C-40 to 125°C
Status Indicator Display None Yes
Weight (typical) 1.11 lb. (437g) 1.17 lb (450g)
Encapsulation Themall y Conductive Epoxy Themally Conductive Epoxy
Recommended Terminal Screw Torque Range: 6-32 Screws - 10 in/lbs. 8-32 Screws - 20 in/lbs.
(Screws dry without grease) 8-32 Screws - 20 in/lbs. (Screws dry without
grease)
Thermal pad installed Yes Yes
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Input circuitry for DC control version incorporates active current limiter (HD and Dual model only)
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
A
gency approvals are for relay only.
E116949 (D2450) E116950 (HD6050, CC2425W3U) LR81689 (D2450, HD6050)
10143 UG (D2450, HD6050)
Rev. 110811
ANNEX - ENVIROMENTAL INFORMATION