LPT100-M Series
130 Watts
Total Power: 130 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Triple
SPECIAL FEATURES
Medical and ITE safeties
Active power factor correction
2” x 4” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail
Adjustable main output
Built-in Class B EMI lter
Overvoltage protection
Overload protection
Thermal overload protection
LPX100 enclosure kit available
RoHS compliant
SAFETY
TUV 60950, 60601-1
UL 60950, 60601-1
CSA 60950, 60601-1
NEMKO 60950, 60601-1
AUSTEL 60950, 60601-1
CB Certicate & report
CE Mark (LVD)
Electrical Specications
Input
Input ra nge 90 - 264 Vac; 127 - 300 Vdc
Frequency 47 - 63 Hz
Inrush current 50 A max., cold start @ 25 °C
Efficiency 82% typical at full load
EMI/RFI FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power 130 W with 200 LFM forced air
Adjustment range
All outputs adjustable: -20%, +10%, except for +24V output on
LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-
M +10%, -15%
Hold-up time 10 ms @ 130 W load, 120 Vac input
Overload protection Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Overvoltage protection 15 - 35% above nominal output
Logical Control
Power failure Active LowTTL logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Data Sheet