Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Inductive sensor Bi5-G18SK-AP6X M18 x 1 24/4 LED 45 77 29 50 threaded barrel, M18 x 1 chrome-plated brass 3-wire DC, 10...30 VDC normally open pnp output terminal chamber Wiring diagram Pg 9 17 pnp Type Ident-No. Bi5-G18SK-AP6X 46420 Rated operating distance Sn Mounting mode Hysteresis (switching distance) Min. repeat accuracy Temperature drift Operating temperature 5 mm flush 3... 15 % 2 % 10 % -25 ...+ 70 C Rated operational voltage (DC) UB 10... 30 VDC Max. ripple 10 % Upp Rated operational current (DC) Ie 200 mA No-load current I0 15 mA Max. OFF-state current Max. switching frequency Rated insulation voltage Output function Short-circuit protection Max. voltage drop at Ie 0,1 mA 1 kHz 0,5 kV 3-wire, normally open, PNP yes, cyclic 1,8 V Wire breakage / reverse polarity protection yes / complete Housing style Dimensions Housing material Active face Max. fixing torque of coupling nut Wiring Clamping ability External diameter cabel Vibration resistance Shock resistance Degree of protection threaded barrel; M18 x 1 77 mm metal, CuZn, chrome-plated plastic, PA12-GF30 25 Nm terminal chamber 2,5 mm2 4,5... 8 mm 55 Hz (1 mm) 30 x g (11 ms) IP67 Switching status indication Included with sensor LED yellow cable gland, 2x plastic seals 1 + 3 4 Function principles Inductive proximity switches are designed for wear-free non-contact detection of metal objects. For this they use a high-frequency electro-magnetic AC field that interacts with the target. With inductive sensors, this field is generated by an LC resonant circuit with a ferrite core coil. Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: * 15.04.2004 Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Inductive sensor Bi5-G18SK-AP6X Mounting instructions Gap D Gap W Gap T Gap S Gap G minimum gap 2xB 3 x Sn 3xB 1,5 x B 6 x Sn Diameter of active face B O 18 mm G S D T W Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: * 15.04.2004 Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Inductive sensor Bi5-G18SK-AP6X Accessories Typ QM-18 IdentNo. 6945102 Description Dimension drawing quick-mount fixing clamp with dead-stop; material: chrome-plated brass external thread M24 x 1,5. 30/5 o 18 BST-18B 6947214 20,5 36 fixing clamp with dead-stop; material: PA6 M5 20 28 40 24 o 18 30 Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: * 15.04.2004 Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264