IP50 (removable connectors)
Mechanical resistance IEC 61373
Railway applications -
Rolling stock
Category 1 class B stock mounted on car
Vibration resistance : 5-
150 Hz
Random sampling : 10 minutes in each direction (X, Y, Z)
Sinusoidal sampling : 5 hours in each direction (X, Y, Z)
Shock resistance : 3 shocks 3 g/30 ms per direction
Dropping : Total of 26 drops on all sides from a height of 1 metre
Mechanical resistance GAM EG 13
Terrestrial military vehicles
Vibration resistance 5-
500 Hz 50 m/s
2
Sinusoidal sampling 5 hours in each direction (X, Y, Z)
Shock resistance :
Acceleration : 150 m/s2, duration : 11 ms, 3 shocks per shaft
Acceleration : 300 m/s2, duration : 11 ms, 3 shocks per shaft
Bumps : 1000 half wave sine mechanical bumps 15 g / 6 ms per shaft
Self-extinguishing UL94V2
UL approved
Self-extinguishing UL94V0
Semi
-rigid polyurethane resin
Solid black appearance
Breakdown voltage : 25 kV/mn
Water absorption : 0.2 % (24 hours at 23 °C)
Shore D hardness : 50
±
5
Smoke category : F1
Processing characteristics of CB, CD, XD & XB product types
CD, XD : Display with 4 lines of 18 characters
Function blocks / SCF (Grafcet) or Ladder
8 Kb : 350 typical blocks, 64 macros maximum, 256 blocks maximum per macro
or
120 lines in Ladder
Back-up time in the event of power failure
Program and settings in the controller : 10 years
Program and settings in the plug
-in memory : 10 years
Data memory : 10 years
FBD:6→90ms(typically20ms)
Ladder : typically 20 ms
Input acquisition time : 1 to 2 cycle times
10 years (lithium battery) at 25 °C
Drift < 12 min/year (at 25 °C)
6 s/month (at 25 °C with user-definable correction of drift)
Start up time on power up
Characteristics of products with AC power supplied
-15 % / +20 %
or20.4VAC→28.8VAC
-15 % / +10 %
or85VAC→264VAC
50/60 Hz (+4 % / -6 %)
or47→53Hz/57→63Hz
50/60 Hz (+ 4 % / -6%)or47→53Hz/57→63Hz
Immunity from micro power cuts
10 ms (repetition 20 times)
10 ms (repetition 20 times)
CB12
-
CD12
-
XD10
-XB10 : 4 VA
CB20
-CD20 : 6 VA
XD10
-XB10 with extension : 7.5 VA
XD26
-XB26 : 7.5 VA
XD26
-XB26 with extension : 10 VA
CB12
-
CD12
-
XD10
-XB10 : 7 VA
CB20
-CD20 : 11 VA
XD10
-XB10 with extension : 12 VA
XD26
-XB26 : 12 VA
XD26
-XB26 with extension : 17 VA
100→240VAC(-15 % / +10 %)
4.4 mA @ 20.4 V AC
5.2 mA @ 24.0 V AC
6.3 mA @ 28.8 V AC
0.24 mA @ 85 V AC
0.75 mA @ 264 V AC
Logic 1 voltage threshold
Making current at logic state 1
Logic 0 voltage threshold
≤20VAC(≤28VAC:XE10,XR06,XR10,XR14)
Release current at logic state 0
Response time with LADDER programming
50 ms
State0→1(50/60Hz)
50 ms
State0→1(50/60Hz)
Response time with function blocks programming
Configurable in increments of 10 ms
50 ms min. up to 255 ms
State0→1(50/60Hz)
Configurable in increments of 10 ms
50 ms min. up to 255 ms
State0→1(50/60Hz)
Maximum counting frequency
In accordance with cycle time (Tc) and input response time (Tr) :
1/ ( (2 x Tc) + Tr)
In accordance with cycle time (Tc) and input response time (Tr) :
1/ ( (2 x Tc) + Tr)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com