D10040200GTH D10040200G TH 401000MHz GaAs Power Doubler Hybrid 40-1000MHz GaAs POWER DOUBLER HYBRID Package: SOT-115J Product Description Features The D10040200GTH is a Hybrid Power Doubler amplifier module. The part employs GaAs die and is operated from 40MHz to 1000MHz. It provides excellent linearity and superior return loss performance with low noise and optimal reliability. +VB Optimum Technology Matching(R) Applied GaAs HBT 9 GaAs MESFET INPUT OUTPUT InGaP HBT Excellent Linearity Superior Return Loss Performance Extremely Low Distortion Optimal Reliability Low Noise Unconditionally Stable Under All Terminations 20.0dB Min. Gain at 1GHz 440mA Max. at 24VDC Applications SiGe BiCMOS Si BiCMOS SiGe HBT 40MHz to 1000MHz CATV Amplifier Systems GaAs pHEMT Si CMOS Si BJT GaN HEMT RF MEMS Parameter Min. Specification Typ. Max. 19.5 20.0 1.0 20.0 21.5 1.5 20.5 22 2.0 Unit Overall Condition VB = 24V; TMB =30C; ZS =ZL =75 Power Gain Slope [1] Flatness of Frequency Response Input Return Loss dB dB dB f=50MHz f=1000MHz f=40MHz to 1000MHz 0.8 dB f=40MHz to 1000MHz (Peak to Valley) dB f=40MHz to 320MHz dB f=320MHz to 640MHz dB f=640MHz to 870MHz dB f=870MHz to 1000MHz Output Return Loss dB f=40MHz to 320MHz dB f=320MHz to 640MHz dB f=640MHz to 870MHz dB f=870MHz to 1000MHz Noise Figure 5.5 6.5 dB f=50MHz to 1000MHz Total Current Consumption (DC) 420.0 440.0 mA 1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. 20.0 19.0 17.0 16.0 20.0 19.0 18.0 17.0 RF MICRO DEVICES(R), RFMD(R), Optimum Technology Matching(R), Enabling Wireless ConnectivityTM, PowerStar(R), POLARISTM TOTAL RADIOTM and UltimateBlueTM are trademarks of RFMD, LLC. BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and registered trademarks are the property of their respective owners. (c)2006, RF Micro Devices, Inc. Document Revision Level B 7628 Thorndike Road, Greensboro, NC 27409-9421 * For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. 1 of 4 D10040200GTH Absolute Maximum Ratings Parameter Rating Unit RF Input Voltage (single tone) 75 dBmV DC Supply Over-Voltage (5 minutes) 30 V Storage Temperature -40 to +100 C Operating Mounting Base Temperature -30 to +100 C Parameter Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2002/95/EC (at time of this document revision). The information in this publication is believed to be accurate and reliable. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended application circuitry and specifications at any time without prior notice. Min. Specification Typ. Max. Unit Distortion data 40MHz to 550MHz Condition VB = 24V; TMB =30C; ZS =ZL =75 CTB -65 -63 dBc 79 ch 7dB tilted; VO =52dBmVat 550MHz[2] XMOD -62 -60 dBc 79 ch 7dB tilted; VO =52dBmVat 550MHz[2] CSO -67 -65 dBc 79 ch 7dB tilted; VO =52dBmVat 550MHz[2] 2. 79 channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +45dBmV to +52dBmV tilted output level. Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) - The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. 2 of 4 7628 Thorndike Road, Greensboro, NC 27409-9421 * For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Document Revision Level B D10040200GTH I U 123 5 7 89 C E J S P R M K O T Q oG N D B H L nominal min A 44,6 0,2 44,4 44,8 B 13,6 0,2 13,4 13,8 C 20,4 0,5 19,9 20,9 D 8 0,15 7,85 8,15 E 12,6 0,15 12,45 12,75 F 38,1 0,2 37,9 38,3 G 4 +0,2 / -0,05 3,95 4,2 9 H 4 0,2 3,8 4,2 I 25,4 0,2 25,2 25,6 OUTPUT All Dimensions in mm: J UNC 6-32 - - K 4,2 0,2 4,0 4,4 L 27,2 0,2 27,0 27,4 M 11,6 0,5 11,1 12,1 N 5,8 0,4 5,4 6,2 O 0,25 0,02 0,23 0,27 P 0,45 0,03 0,42 0,48 Q 2,54 0,3 2,24 2,84 R 2,54 0,5 2,04 3,04 S 2,54 0,25 2,29 2,79 T 5,08 0,25 4,83 5,33 U 5,08 0,25 4,83 5,33 F A Pinning: 0 5 10mm 1 2 3 4 5 6 7 8 Notes: Document Revision Level B European Projection GND GND +VB GND GND INPUT scale 7628 Thorndike Road, Greensboro, NC 27409-9421 * For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. max 3 of 4 D10040200GTH 4 of 4 7628 Thorndike Road, Greensboro, NC 27409-9421 * For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Document Revision Level B