ARINC 600
Hypertronics Corporation Toll Free: 1-800-225-9228 Tel: 978-568-0451 Fax: 978-568-0680 www.hypertronics.com 3
Dielectric withstanding voltage (DWV)
1500 V rms
500 V rms @ 50,000 ft (15,240 m)
Contact continuous current ratings
Size 22 – 5.0A; Size 20 – 7.5A
Size 16 – 13.0A; Size 12 – 23.0A
Contact resistance (max):
Size 22
Size 20
Size 16
Size 12
Initial After
conditioning
Insulation resistance 5.0 GΩmin. @ 500 Vdc
Mechanical endurance 500 cycles min – mating and unmating
Temperature range -65 deg C to + 125 deg C
Fluid immersion resistance (Class E only) (1) Hydraulic fluid to Mil-PRF-5606
(2) Lubricating oil (synthetic) to Mil-PRF-23699
(3) 1:3 mix of isopropyl alcohol and mineral spirits per FED,
SPEC TT-I-735 and TT-T-291 respectively
Shock MIL-Std-1344, method 2004.1, test condtion A: Three shocks in
each direction along each of 3 axes, mutually perpendicular to
each other. No visible damage, breakage, cracking or loosening of
parts and no electrical discontinuities exceeding 1 micro-second
Vibration Mil – Std-1344, method 2005.1, condition value E, random –
16.4g minimum severity, 8 hours in each of 3 mutually
perpendicular planes with 100 mA electrical load. No visible
damage, breakage, cracking or loosening of parts, and no
electrical discontinuities exceeding 1 micro-second
Engagement / separation force Shell size 1 - 27 lbs (120N) max
Shell size 2 - 60 lbs (267N) max
Shell size 3 - 105 lbs (467N) max
PERFORMANCE SPECIFICATION
ARINC 600 OVERVIEW AND SPECIFICATION
Shells Aluminium alloy electroless nickel plate
Retaining plates Aluminium alloy electroless nickel plate
Polarizing posts/keys Post – Stainless Steel passivated
Keys – Aluminium Alloy, Alodine 1200
Inserts Glass filled epoxy
Fixing screws and washers Stainless steel, passivated
Contact bodies Copper alloy, gold over nickel
Contact retention clips Beryllium copper
Seals and grommets Fluorosilicone elastomer to Mil-R-25988
EMI springs Beryllium copper
Protection covers Conductive Polymer
Inserts (metallic) Aluminium alloy electroless nickel plate
MATERIAL SPECIFICATION
ARINC 600 AIRFRAME,
AVIONICS BOXES
■Signal, power, databus and coaxial contacts
■Pin size/current: size 22, 20, 16 and 12
contacts have 5A, 7.5A, 13.0A and 23.0A
current ratings respectively
■Approvals: conforms to MIL-C-81659 B,
BACC 66 specifications
■Custom filtering and lightning protection