USP-225 225W Single Output with PFC Function series Features : Universal AC input / Full range Built in active PFC circuit compliance to EN61000-3-2 Protections: Short circuit / Overload / Over voltage / Over temperature Free air convection for 150W and forced air convection for 225W High power density 4.7w/in Active AC surge current limiting U-bracket low profile:38mm 3 years warranty 3 Bauar t gepruft Sicherheit egel ma ge o s od g be wac SPECIFICATION www. tuv.com ID 2000000000 MODEL OUTPUT USP-225-5 USP-225-12 USP-225-15 USP-225-24 USP-225-48 3.3V 5V 12V 15V 24V 48V RATED CURRENT 40A 40A 18.7A 15A 9.4A 4.7A CURRENT RANGE 0 ~ 40A 0 ~ 40A 0 ~ 18.7A 0 ~ 15A 0 ~ 9.4A 0 ~ 4.7A RATED POWER 132W 200W 224.4W 225W 225.6W 225.6W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 250mVp-p VOLTAGE ADJ. RANGE 2.97 ~ 3.6V VOLTAGE TOLERANCE Note.3 2.0% 4.5 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V 2.0% 2.0% 2.0% 2.0% 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 22ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 72% 77% 85% 86% 2.2A 3.3A 115VAC 230VAC INRUSH CURRENT (Typ.) PROTECTION 1.1A 15A/115VAC 1200ms, 30ms/115VAC at full load 22ms/115VAC at full load 127 ~ 370VDC ND AC CURRENT (Typ.) NR INPUT USP-225-3.3 DC VOLTAGE PF>0.97/115VAC at full load 83% 84% 1.6A 35A/230VAC LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE 3.6 ~ 4.4V 5.5 ~ 7.4V 13.2 ~ 16.3V 16.5 ~ 20.2V OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -20 ~ +65 (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -40 ~ +85, 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 MTBF 220K hrs min. MIL-HDBK-217F (25) 202*101.5*38mm (L*W*H) 0.85Kg; 16pcs/14.6Kg/0.76CUFT OTHERS DIMENSION PACKING NOTE 52.8 ~ 64.8V 20 ~ 90% RH non-condensing SAFETY & (Note 4) 26.4 ~ 32.4V I/P-FG:2KVAC O/P-FG:0.5KVAC Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:USP-225-SPEC 2018-01-15 USP-225 225W Single Output with PFC Function Mechanical Specification Case No. 928 series Unit:mm 202 198.25 60 65.75 FAN Air flow direction 38 8 3.75 15cm 18CFM 2 - 48.5 93.5 10 9 8 7 6 5 4 3 2 1 2-M 3 CN1 101.5 CN2 1 2 3 FS1 F6.3A/250V AC Input Connector (CN1) : JST B3P-VH or equivalent Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent ACTIVE INRUSH CURRENT LIMITING EMI FILTER Pin No. 1~5 6~15 16~20 Assignment +V -V +V ND Block Diagram RECTIFIERS & P.F.C. 11 12 13 14 15 16 17 18 19 20 DC Output Connector (CN2) : MOLEX 39-29-9206 or equivalent NR Pin No. 1 2 3 I/P 3.2 LED POWER SWITCHING Mating Housing Terminal MOLEX 5557 or equivalent MOLEX 5556 or equivalent fosc : 100KHz RECTIFIERS & FILTER Derating Curve O.T.P. With18CFM Forced Air Convection 3.3V,5V Model With 18CFM Forced Air Convection 90 80 Free Air Convection LOAD(%) LOAD (%) 70 3.3V,5V Model Free Air Convection 40 20 -20 O.V.P. 100 65 60 50 DETECTION CIRCUIT PWM CONTROL Static Characteristics (5V) 100 80 -V O.C.P. FG O.L.P. +V 0 10 20 30 40 45 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:USP-225-SPEC 2018-01-15