2001 2002 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter * True 71/2- (Model 2001) or 81/2-digit (Model 2002) resolution * Exceptional measurement integrity with high speed * High speed function and range changing * Broad range of built-in measurement functions * Multiple measurement display * Built-in 10 channel scanner option * GPIB interface * HP3458A emulation mode (Model 2002) Built-In Scanner (Multiplexer) Options With the addition of a plug-in scanner card, the 2001 or 2002 becomes a complete scan and measure system for applications involving up to ten measurement points. The additional resolution and measurement ranges provided by the 2002 make it an excellent choice for production test, design verification, and metrology applications where high accuracy is c ritical. High resolution, high accuracy DMMs True 71/2- (or 81/2-) Digit Resolution While other DMMs may claim 71/2- or 81/2-digit resolution, they must average multiple readings to extend their resolution. The resolution specifications of the 2001 and 2002 are based on a 28-bit A/D converter that provides the resolution needed to discern smaller changes. This higher resolution also provides greater dynamic range, making it possible to measure from 1V to 20V on a single range, thus avoiding range-shift errors and delays. High Accuracy ACV Measurements A patented circuit design makes the 2001 and 2002's AC measurements several times more accurate than competitive DMMs. In this circuit, the signal bypasses the prime error-contributing section of conventional rms converters. This increases the accuracy at almost any voltage level, and also increases sensitivity down to a guaranteed 1% of the selected range, compared to 5-10% for most other DMMs. The result is highly accurate measurements over a broad range of inputs. Applications involving vibration, servo, guidance, shock, and control systems often require accurate low frequency ACV measurements. The 2001 and 2002 maintain very good accuracy (better than 0.1%) down to 1Hz. The wide bandwidth of these DMMs allows for accurate measurements of high frequency AC signals without the need for a special AC meter. Both the 2001 and 2002 feature TRMS AC, average AC, peak AC, AC+DC, and crest factor measurement capability for a wide variety of a pplications. High Speed for High Throughput In applications where high throughput is critical, both the 2001 and 2002 provide more than 2000 readings per second at 41/2-digit resolution. At 71/2 digits, the 2002 maintains full rated accuracy at reading rates up to 44/second on DCV and ohms. High Speed, High Precision Resistance Measurements The Model 2002 uses a unique single-phase method for 4-wire ohms measurements. This makes it twice as fast for a given power line cycle rate. This also eliminates errors due to changing lead resistances that can result from fast test handlers. A built-in open-lead detection circuit also eliminates many production test problems. Fast, Flexible Triggering Trigger latency--the delay between trigger and measurement--is often a barrier to higher throughput. Also, variability in latency can complicate predicting measurement timing. The 2001 and 2002 trigger is less than 2s1s, which is much faster than typical system DMMs. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence DIGITAL MULTIMETERS & SYSTEMS High resolution, high accuracy DMMs DMM users whose applications demand exceptional resolution, accuracy, and sensitivity combined with high throughput now have two attractive alternatives to high priced, high end DMMs. Keithley's 71/2-digit Model 2001 and 81/2-digit Model 2002 High Performance Digital Multimeters not only deliver performance specifications usually associated with instruments that cost thousands more, but they also offer a broad range of functions not typically available from DMMs. The 2002 is based on the same superior measurement technology as the 2001, and the front panels of both instruments have the same look, feel, and response. 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter High resolution, high accuracy DMMs Ordering Information 2001 High Performance 71/2-Digit DMM with 8K Memory 2002 High Performance 81/2-Digit DMM with 8K Memory 2000-SCAN 10-channel Scanner Card 2001-SCAN 10-channel Scanner Card with two highspeed channels 2001-TCSCAN 9-channel Thermocouple Scanner Card 2001/MEM1 High Performance 71/2-Digit DMM with 32K Memory 2001/MEM2 High Performance 71/2-Digit DMM with 128K Memory 2002/MEM1 High Performance 81/2-Digit DMM with 32K Memory 2002/MEM2 High Performance 81/2-Digit DMM with 128K Memory DIGITAL MULTIMETERS & SYSTEMS Accessories Supplied Model 8605 High Performance Modular Test Leads, user's manual, option slot cover, and full calibration data. Model 2002 1p 10-12 1n 10-9 DC Voltage Model 2001 1 10-6 1m 10-3 1 100 1nV 10nV AC Voltage 1M 106 100nV 775Vrms 1Hz DC Current 10pA 2MHz 2.1A DC In-Circuit Current 100A 12A 100pA 2.1A Frequency 1Hz Frequency Sensitivity 15MHz 60mV Period 1G 109 1100V 1100V AC Voltage Bandwidth AC Current 1k 103 67ns 775Vrms 1s Crest Factor 20Hz Peak Spikes-Repetitive 500ns Peak Spikes-Single 1MHz 16s 2s Resistance 2-Wire 100n 1 Resistance 4-Wire 100n 1 16s 1G 1G 2.1M 210k Logarithmic scale --500 Temperature-RTD -200 Temperature-TC -200 0 500 1000 1500 2000 630C 1820C Linear scale Both the 2001 and 2002 provide exceptional measurement range. In addition, the 2002 offers extended DCV and resistance measurement capabilities. The unique Trigger-Link feature included in the Model 2001 and 2002 and most Keithley test and measurement products can be used to coordinate the operation of two or more instruments. Trigger-Link combines six independent software selectable trigger lines on a single connector for simple, direct control over all instruments in a system. Spot Trends with the Bar-Graph Display The ability to track reading trends around a target value easily can be just as important as the absolute readings. A unique bar-graph display function in the 2001 and 2002 indicates data as a percentage of the selected range from 0.01% to 100%. Whether adjusting about zero or any other desired value, this display can replace a nulling differential voltmeter. Capture Spikes Down to 1s Both the 2001 and 2002 have internal peak detectors that can catch 1s spikes such as power supply spikes and transients, AC line power surges, and short-duration dropouts on components. These peak detectors operate up to 1MHz for repetitive signals or down to 1s for single spikes, so there is no need for a separate scope. The DMMs can automatically display and store the highest value or display the maximum and minimum values of spikes. For more information, request the Model 2001 and 2002 Technical Specifications books. Built-in Features and Capabilities The 2001 and 2002 offer many built-in measurements that are typically unavailable in instruments of this type, including in-circuit current, temperature with thermocouples or RTDs, and peak spikes. Four separate outputs linked to limits simplify configuring the DMMs for use in binning operations. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence High resolution, high accuracy DMMs 2001 2002 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter The built-in AC crest factor measurement helps ensure the accuracy of AC measurements. Other DMMs typically perform AC measurements for signals without excessive crest factor--the ratio of peak value to rms values. However, when crest factor rises, measurements may not meet specs. With a 2001 or 2002, there is no need for an oscilloscope to determine if the crest factor is acceptable--the DMM measures it directly. and 2002 have a fully adjustable trigger level for good measurements of noisy signals. When measuring AC or digital signals, frequency is critical. The 2001 and 2002 accurately measure frequency up to 15MHz. Accurate triggering on the signal is critical to measure frequency reliably. The frequency counters in the 2001 Option Slot Extends DMM Performance An option slot in the back of the 2001 and 2002 opens the door to a wide range of measurement capabilities. Choose a 10-channel general-purpose scanner card or a 9-channel thermocouple scanner card to make measurements on multiple test points or devices. This can eliminate the need for a separate scanner and significantly reduce programming and setup time. Cables/Adapters 7007-1 Shielded GPIB Cable, 1m (3.3 ft) 7007-2 Shielded GPIB Cable, 2m (6.6 ft) 8501-1 Trigger-Link Cable, 1m (3.3 ft) 8501-2 Trigger Link Cable, 2m (6.6 ft) 8502 Trigger Link Adapter Box 8610 Low Thermal Shorting Plug 8620 4-Wire DMM Shorting Plug Rack Mount Kits 4288-1 Single Fixed Rack Mount Kit 4288-4 Side-by-Side Rack Mount Kit GPIB Interfaces KPCI-488LPA IEEE-488 Interface Controller for the PCI Bus KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter High resolution, high accuracy DMMs While some DMMs calculate average AC from the rms value, these calculations apply only to sine wave inputs. The 2001 and 2002 measure peak value, average and true rms directly to obtain a complete characterization of the signal. This capability makes these DMMs ideal for AC circuit design or test applications and for verifying test voltages specified only in averages. Multiple Measurement Display The 2001 and 2002 can display DC and AC volts and the AC frequency from a single measurement connection simultaneously. Several other multiple-measurement displays are available, including crest factor and bar graph. By measuring sequentially and displaying simultaneously, the 2001/2002 operates as if three different meters are working together. Accessories Available Test Leads and Probes 5805 Kelvin Probes, 0.9m (3ft) Kelvin Probes, 3.6m (12ft) 5805-12 5808 Low Cost, Single Pin, Kelvin Probes Low Cost, Kelvin Clip Lead Set 5809 8502 Micro-DIN to 6 BNCs Adapter Box with 8501-1 Cable 8530 Centronics Adapter High Performance 2-Wire Modular Test Leads 8605 8606 High Performance Modular Probe Kit Low Thermal Shorting Plug 8610 RTD Probe Adapter 8680 8681 Low Cost RTD Services Available 2000-SCAN-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2001/MEM1-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2001/MEM2-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2001-SCAN-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2001-TCSCAN-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2001-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2002/MEM1-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2002/MEM2-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2002-3Y-EW 1-year factory warranty extended to 3 years from date of shipment C/2000-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase for Model 2000-SCAN* C/2001-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase for Models 2001, 2001/MEM1, 2001/MEM2, 2001-SCAN, 2001-TCSCAN* C/2002-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase for Models 2002, 2002/MEM1, 2002/MEM2* *Not available in all countries 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence DIGITAL MULTIMETERS & SYSTEMS High resolution, high accuracy DMMs 2001 2002 2001 2002 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter 2001 Condensed Specifications DC VOLTS Model 2001 and 2002 specifications Range 200 mV 3 2 V 20 V 200 V 1000 V Full Scale 210.00000 mV 2.1000000 V 21.000000 V 210.00000 V 1100.0000 V Default Resolution Resolution 10 nV 100 nV 100 nV 1V 1V 10V 10V 100V 100V 1 mV Input Resistance >10 GW >10 GW >10 GW 10 MW 1% 10 MW 1% Accuracy (ppm of reading + ppm of range) 5 24 90 1 2 Minutes4 Hours1 Days2 Year 2 Years2 3+3 10 + 6 25 + 6 37 + 6 50 + 6 2 + 1.5 7+2 18 + 2 25 + 2 32 + 2 2 + 1.5 7+4 18 + 4 24 + 4 32 + 4 2 + 1.5 27 + 3 38 + 3 52 + 3 13 + 3 10 + 1.5 17 + 6 31 + 6 41 + 6 55 + 6 AC VOLTS Normal Mode RMS1 90 Days, 2C from last AC self-cal for 1% to 100% of range2 (% of reading + % of range) Range 200 mV 2 V 20 V 200 V 3 750 V 3 20-50Hz 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 50-100Hz 0.07 + 0.015 0.07 + 0.015 0.07 + 0.015 0.07 + 0.015 0.1 + 0.015 0.1-2kHz 0.03 + 0.015 0.03 + 0.015 0.04 + 0.015 0.04 + 0.015 0.08 + 0.015 2-10kHz 0.03 + 0.015 0.03 + 0.015 0.06 + 0.015 0.06 + 0.015 0.09 + 0.015 10-30kHz 0.035 + 0.015 0.035 + 0.015 0.08 + 0.015 0.08 + 0.015 0.12 + 0.015 30-50kHz 0.05 + 0.015 0.05 + 0.015 0.1 + 0.015 0.1 + 0.015 0.15 + 0.015 4 50-100kHz 100-200kHz 0.3 + 0.015 0.75 + 0.025 0.3 + 0.015 0.75 + 0.025 0.3 + 0.015 0.75 + 0.025 0.3 + 0.015 0.75 + 0.025 4 0.5 + 0.015 4 0.2-1MHz 2 + 0.1 2 + 0.1 4 + 0.2 4 + 0.2 4 1-2MHz 5 + 0.2 5 + 0.2 7 + 0.2 4 AC VOLTS NOTES 1. 2. 3. 4. Specifications apply for sinewave input, AC + DC coupling, 1 power line cycle, digital filter off, following 55 minute warm-up. For 1% to 5% of range below 750V range, and for 1% to 7% of 750V range, add 0.01% to range uncertainty. For inputs from 200kHz to 2MHz, specifications apply above 10% of range. Add 0.001% of reading x (V IN/100V)2 additional uncertainty above 100V rms. Typical values. OHMS OHMS NOTES TWO-WIRE AND FOUR-WIRE OHMS (2W and 4W Ohms Functions) 6 Resistance Accuracy 3 (ppm of reading + ppm of range) Range 20 W 200 W 2 kW 20 kW 200 kW 2 MW 2 20 MW 2 200 MW 2 1 GW 2 DIGITAL MULTIMETERS & SYSTEMS 1. For TCAL 1C, following 55-minute warm-up. TCAL is ambient temperature at calibration, which is 23C from factory. 2. For TCAL 5C, following 55-minute warm-up. Specifications include factory traceability to US NIST. 3. When properly zeroed using REL function. 4. DCV Transfer Stability typical applications are standard cell comparisons and relative accuracy measurements. Specs apply for 10 power line cycles, 20-reading digital filter, autozero on with type synchronous, fixed range following 2-hour warm-up at full scale to 10% of full scale, at T REF 1C (T REF is the initial ambient temperature). Specifications on the 1000V range are for measurements within 5% of the initial measurement value and following measurement settling. Full Scale 21.000000 W 210.00000 W 2100.0000 kW 21.000000 kW 210.00000 kW 2.1000000 MW 21.000000 MW 210.00000 MW 1.0500000 GW Default Current Resolution Resolution Source 1 24 Hours 4 90 Days 5 1 Year 5 2 Years 5 9.2 mA 29 + 7 52 + 7 72 + 7 110 + 7 1W 10W 0.98 mA 24 + 7 36 + 7 56 + 7 90 + 7 10W 100W 0.98 mA 22 + 4 33 + 4 50 + 4 80 + 4.5 100W 1 mW 89A 19 + 4 32 + 4 50 + 4 80 + 4.5 1 mW 10 mW 7A 20 + 4.5 72 + 4.5 90 + 4.5 130 + 5 10 mW 100 mW 770 nA 50 + 4.5 110 + 4.5 160 + 4.5 230 + 5 100 mW 1 W 560 + 4.5 900 + 4.5 1100 + 5 70 nA 160 + 4.5 1 W 10 W 4.4 nA 3000 + 100 10000 +100 20000 + 100 30000 + 100 10 W 100 W 4.4 nA 9000 + 100 20000 +100 40000 + 100 60000 + 100 100 W 1 kW 1. Current source is typically 9% absolute accuracy. 2. For 2-wire mode. 3. Specifications are for 1 power line cycle, 10 reading digital filter, Auto Zero on, 4-wire mode, offset compensation on (for 20W to 20kW ranges). 4. For TCAL 1C, following 55 minute warm-up. TCAL is ambient temperature at calibration (23C at the factory). 5. For TCAL 5C, following 55-minute warm-up. Specifications include traceability to US NIST. 6. When measuring resistance of inductive loads, the inductance of that load must be 10mH or less. DC AMPS DC AMPS NOTES DCI INPUT CHARACTERISTICS AND ACCURACY4 1. Specifications are for 1 power line cycle, Auto Zero on, 10 reading digital filter. 2. For TCAL 1C, following 55 minute warm-up. 3. For TCAL 5C, following 55 minute warm-up. Specifications include traceability to US NIST. 4. Add 50 ppm of range for current above 0.5A for self heating. 6. Actual maximum voltage burden = (maximum voltage burden) x (I MEASURED/I FULL SCALE). Range 200A 2 mA 20 mA 200 mA 2 A Full Scale 210.00000A 2.1000000 mA 21.000000 mA 210.00000 mA 2.1000000 A Resolution 10 pA 100 pA 1 nA 10 nA 100 nA Default Resolution 100 pA 1 nA 10 nA 100 nA 1A Maximum Burden Voltage6 0.25 V 0.31 V 0.4 V 0.5 V 1.5 V Accuracy1 (ppm of reading + ppm of range) 24 Hours2 63 + 25 64 + 20 65 + 20 96 + 20 500 + 20 90 Days3 300 + 25 300 + 20 300 + 20 300 + 20 600 + 20 1 Year3 500 + 25 400 + 20 400 + 20 500 + 20 900 + 20 2 Years3 1350 + 25 750 + 20 750 + 20 750 + 20 1350 + 20 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Model 2001 and 2002 specifications DC VOLTS NOTES DCV INPUT CHARACTERISTICS AND ACCURACY 2001 2002 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter 2001 Condensed Specifications (continued) AC AMPS AC AMPS NOTES 20Hz- 50Hz 0.35 + 0.015 0.3 + 0.015 0.3 + 0.015 0.3 + 0.015 0.35 + 0.015 50Hz- 200Hz 0.2 + 0.015 0.15 + 0.015 0.15 + 0.015 0.15 + 0.015 0.2 + 0.015 200Hz- 1kHz 0.4 + 0.015 0.12 + 0.015 0.12 + 0.015 0.12 + 0.015 0.3 + 0.015 1kHz- 10kHz 0.5 + 0.015 0.12 + 0.015 0.12 + 0.015 0.15 + 0.015 0.45 + 0.015 10kHz- 30kHz3 0.25 + 0.015 0.25 + 0.015 0.5 + 0.015 1.5 + 0.015 30kHz- 50kHz3 50kHz- 100kHz3 0.3 + 0.015 0.3 + 0.015 1 + 0.015 4 + 0.015 0.5 + 0.015 0.5 + 0.015 3 + 0.015 FREQUENCY COUNTER GENERAL AC Voltage Input: 1Hz-15MHz. ACCURACY: (0.03% of reading). POWER: Voltage: 90-134V and 180-250V, universal self-selecting. Frequency: 50Hz, 60Hz, or 400Hz self-identifying. Consumption: <55VA. ENVIRONMENTAL: Operating Temperature: 0 to 50C. Storage Temperature: -40 to 70C. Humidity: 80% R.H., 0 to 35C, per MIL-T-28800E1 Para 4.5.5.1.2. PHYSICAL: Case Dimensions: 90mm high x 214mm wide x 369mm deep (31/2 in. x 81/2 in. x 141/2 in.). Net Weight: <4.2kg (<9.2 lbs.). Shipping Weight: <9.1kg (<20 lbs.). STANDARDS EMI/RFI: Conforms to VDE 0871B (per Vfg 1046/1984), IEC 801-2. Meets FCC part 15 Class B, CISPR-22 (EN55022). Safety: Conforms to IEC348, CAN/CSA-C22.2. No. 231, MIL-T-28800E1. Designed to UL1244. Note 1: For MIL-T-28800E, applies to Type III, Class 5, Style E. DC IN-CIRCUIT CURRENT TYPICAL RANGES: Current: 100A to 12A. Trace Resistance: 1mW to 10W typical. Accuracy: (5% + 2 counts). For 1 power line cycle, Auto Zero on, 10 reading digital filter, TCAL 5C, after being properly zeroed. 90 days, 1 year or 2 years. TEMPERATURE Built-in linearization for J, K, N, T, E, R, S, B thermocouple types to ITS-90 and 100W platinum RTDs DIN 43 760 or IPTS-68. Model 2001 and 2002 specifications RANGE 200A 2 mA 20 mA 200 mA 2 A 1. Specifications apply for sinewave input, AC+DC coupling, 1 power line cycle, digital filter off, following 55 minute warm-up. 2. Add 0.005% of range uncertainty for current above 0.5A rms for selfheating. 3. Typical values. For complete specifications, refer to the 2001 Technical Data book. 2002 Condensed Specifications DC Volts DC Volts Notes DCV Input Characteristics and Accuracy Enhanced Accuracy - 10PLC, DFILT 10 Relative Accuracy (ppm of reading + ppm of range) 1 Range 200 mV 4 2 V4 20 V 200 V 1000 V 6 Input Full Scale Resolution Resistance Transfer 5 24 Hours 2 90 Days 3 210.000000 mV 1 nV 3.5 + 3 15 + 8 0.4 + 1.5 >100 GW 0.2 + 0.15 2.10000000 V 10 nV 1.2 + 0.3 6 + 0.8 >100 GW 100 nV 0.1 + 0.05 6 + 0.15 21.0000000 V 1.2 + 0.1 >100 GW 210.000000 V 1V 14 + 2 5 + 0.4 10 MW 1% 0.5 + 0.08 1100.00000 V 10V 1 + 0.05 5 + 0.08 14 + 0.4 10 MW 1% Full Scale 210.00000 mV 2.1000000 V 21.000000 V 210.00000 V 1100.0000 V Resolution 10 nV 100 nV 1V 10V 100V 2 Years 3 23 + 10 14 + 1 14 + 0.15 30 + 2 30 + 0.4 Relative Accuracy (ppm of reading + ppm of range) Normal Accuracy 7 - 1PLC, DFILT off Range 200 mV 4 2 V4 20 V 200 V 1000 V 6 1 Year 3 19 + 9 10 + 0.9 10 + 0.15 22 + 2 22 + 0.4 Input Resistance 24 Hours2 3.5 + 6 >100 GW 1.2 + 0.6 >100 GW 3.2 + 0.35 >100 GW 5 + 1.2 10 MW 1% 5 + 0.4 10 MW 1% AC Volts Normal Mode rms1 90 Days3 15 + 11 6 + 1.1 8 + 0.4 14 + 2.8 14 + 0.7 1 Year3 19 + 12 10 + 1.2 12 + 0.4 22 + 2.8 22 + 0.7 1. Specifications are for 10 power line cycles, synchronous autozero, 10-reading repeat digital filter, autorange off, except as noted. 2. For TCAL 1C, following 4-hour warm-up. TCAL is ambient temperature at calibration (23C at the factory). Add 0.5ppm of reading uncertainty if the unit is power cycled during this interval. 3. For TCAL 5C, following 4-hour warm-up. 4. Care must be taken to minimize thermal offsets due to operator cables. 5. Specifications apply for 20-reading repeat digital filter, T REF 0.5C (T REF is the initial ambient temperature), and for measurements within 10% of the initial measurement value and within 10 minutes of the initial measurement time. 6. Add 20ppm x (V IN/1000V)2 additional uncertainty for inputs above 200V, except in transfer accuracy specifications. 7. Specifications are for 1 power line cycle, normal autozero, digital filter off, autorange off. 2 Years3 23 + 13 14 + 1.3 16 + 0.4 30 + 2.8 30 + 0.7 AC Volts Notes 1. Specifications apply for sinewave input, AC + DC coupling, 1 power line cycle, autozero on, digital filter off, following 55-minute warm-up. 10-30kHz 30-50kHz 50-100kHz 100-200kHz 0.2-1MHz 1-2MHz 2. For 1% to 5% of range below 750V range, and for 1% to 7% of 750V range, add 0.01% of 0.025 + 0.02 0.05 + 0.01 0.3 + 0.015 0.75 + 0.025 2 + 0.1 5 + 0.2 range uncertainty. For inputs from 200kHz 0.025 + 0.02 0.05 + 0.01 0.3 + 0.015 0.75 + 0.025 2 + 0.1 5 + 0.2 to 2MHz, specifications apply above 10% of 4 range. 0.05 + 0.015 0.07 + 0.015 0.3 + 0.015 0.75 + 0.025 4 + 0.2 7 + 0.2 4 4 3. Add 0.001% of reading x (V IN/100V)2 addi0.05 + 0.015 0.07 + 0.015 0.3 + 0.015 0.75 + 0.025 4 + 0.2 tional uncertainty for inputs above 100V rms. 4 4 0.08 + 0.015 0.1 + 0.015 0.5 + 0.015 4. Typical values. 90 Days, 1 Year or 2 Years, 2C from last AC self-cal, for 1% to 100% of range 2 (% of reading + % of range) Range 200 mV 2 V 20 V 200 V 3 750 V 3 20-50Hz 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 0.25 + 0.015 50-100Hz 0.07 + 0.015 0.07 + 0.015 0.07 + 0.015 0.07 + 0.015 0.1 + 0.015 0.1-2kHz 0.02 + 0.02 0.02 + 0.02 0.03 + 0.015 0.03 + 0.015 0.05 + 0.015 2-10kHz 0.02 + 0.02 0.02 + 0.02 0.04 + 0.015 0.04 + 0.015 0.06 + 0.015 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence DIGITAL MULTIMETERS & SYSTEMS Model 2001 and 2002 specifications ACI ACCURACY1, 2 90 Days, 1 Year or 2 Years, TCAL 5C, for 5% to 100% of range, (% of reading + % of range) 2001 2002 71/2-Digit High Performance Multimeter 81/2-Digit High Performance Multimeter 2002 Condensed Specifications (continued) Ohms Model 2001 and 2002 specifications Range 20 W 200 W 2 kW 20 kW 200 kW 2 MW 20 MW 2 200 MW 2 1 GW 2 Full Scale 21.000000 W 210.00000 W 2100.0000 kW 21.000000 kW 210.00000 kW 2.1000000 MW 21.000000 MW 210.00000 MW 1.0500000 GW Resolution 100 nW 1W 10W 100W 1 mW 10 mW 100 mW 1 W 10 W Current Source 1 7.2 mA 960 A 960 A 96 A 9.6 A 1.9 A 1.4 A 6 1.4 A 6 1.4 A 6 Relative Accuracy 3 (ppm of reading + ppm of range) Transfer 7 2.5 + 3 2.5 + 2 1.3 + 0.2 1.3 + 0.2 2.5 + 0.4 5 + 0.2 15 + 0.1 50 + 0.5 250 + 2.5 24 Hours 4 5 + 4.5 5+3 2.5 + 0.3 2.5 + 0.3 5.5 + 0.5 12 + 0.3 50 + 0.2 150 + 1 750 + 5 90 Days 5 15 + 6 15 + 4 7 + 0.4 7 + 0.4 29 + 0.8 53 + 0.5 175 + 0.6 500 + 3 2000 + 15 1 Year 5 17 + 6 17 + 4 9 + 0.4 9 + 0.4 35 + 0.9 65 + 0.5 250 + 0.6 550 + 3 2050 + 15 2 Years 5 20 + 6 20 + 4 11 + 0.4 11 + 0.4 40 + 1 75 + 0.5 300 + 0.6 600 + 3 2100 + 15 DC Amps DC Amps Notes DCI INPUT CHARACTERISTICS AND ACCURACY Range 200A 2 mA 20 mA 200 mA 2 A Full Scale 210.00000A 2.1000000 mA 21.000000 mA 210.00000 mA 2.1000000 A Resolution 10 pA 100 pA 1 nA 10 nA 100 nA Maximum Burden Voltage 3 0.25 V 0.3 V 0.35 V 0.35 V 1.1 V Relative Accuracy (ppm of reading + ppm of range) 24 Hours 1 50 + 6 50 + 5 50 + 5 75 + 5 350 + 5 90 Days 2 275 + 25 275 + 20 275 + 20 300 + 20 600 + 20 1 Year 2 350 + 25 350 + 20 350 + 20 375 + 20 750 + 20 2 Years 2 500 + 25 500 + 20 500 + 20 525 + 20 1000 + 20 AC Amps 20Hz- 50Hz 0.35 + 0.015 0.3 + 0.015 0.3 + 0.015 0.3 + 0.015 0.35 + 0.015 50Hz- 200Hz 0.2 + 0.015 0.15 + 0.015 0.15 + 0.015 0.15 + 0.015 0.2 + 0.015 200Hz- 1kHz 0.4 + 0.015 0.12 + 0.015 0.12 + 0.015 0.12 + 0.015 0.3 + 0.015 1kHz- 10kHz 0.5 + 0.015 0.12 + 0.015 0.12 + 0.015 0.15 + 0.015 0.45 + 0.015 10kHz- 30kHz3 0.25 + 0.015 0.25 + 0.015 0.5 + 0.015 1.5 + 0.015 FREQUENCY COUNTER AC Voltage Input: 1Hz-15 MHz. ACCURACY: (0.03% of reading). DC IN-CIRCUIT CURRENT DIGITAL MULTIMETERS & SYSTEMS 1. For TCAL 1C, following 55-minute warm-up. TCAL is ambient temperature at calibration (23C at the factory). 2. For TCAL 5C, following 55-minute warm-up. 3. Actual maximum burden voltage = (maximum burden voltage) x (I MEASURED/I FULL SCALE). AC Amps Notes ACI Accuracy 1, 2 90 Days, 1 Year or 2 Years, TCAL 5C, for 5% to 100% of range, (% of reading + % of range) Range 200A 2 mA 20 mA 200 mA 2 A 1. Current source has an absolute accuracy of 5%. 2. For 2-wire mode. 3. Specifications are for 10 power line cycles, 10-reading repeat digital filter, synchronous autozero, autorange off, 4-wire mode, offset compensation on (for 20W to 20kW ranges), except as noted. 4. For TCAL 1C, following 4-hour warm-up. TCAL is ambient temperature at calibration (23C at the factory). 5. For TCAL 5C, following 4-hour warm-up. 6. Current source is paralleled with a 10MW resistance. 7. Specifications apply for 20-reading repeat digital filter, T REF 0.5C (T REF is the initial ambient temperature), and for measurements within 10% of the initial measurement value and within 10 minutes of the initial measurement time. TYPICAL RANGES: Current: 100A to 12A. Trace Resistance: 1mW to 10W. Accuracy: (5% + 500A). For 1 power line cycle, autozero on, 10-reading digital filter, TCAL 5C, 90 days, 1 year or 2 years. TEMPERATURE Built-in linearization for J, K, N, T, E, R, S, B thermocouple types to ITS-90 and 100W platinum RTDs DIN 43760, IPTS-68, and ITS-90. 30kHz- 50kHz3 50kHz- 100kHz3 0.3 + 0.015 0.3 + 0.015 1 + 0.015 4 + 0.015 0.5 + 0.015 0.5 + 0.015 3 + 0.015 1 Specifications apply for sinewave input, AC+DC coupling, 1 power line cycle, autozero on, digital filter off, following 55-minute warm-up. 2 Add 0.005% of range uncertainty for current above 0.5A rms for self-heating. 3. Typical values. General POWER: Voltage: 90-134V and 180-250V, universal self-selecting. Frequency: 50Hz, 60Hz, or 400Hz self-identifying at power-up. Consumption: <55VA. ENVIRONMENTAL: Operating Temperature: 0 to 50C. Storage Temperature: -40 to 70C. Humidity: 80% R.H., 0 to 35C. PHYSICAL: Case Dimensions: 90mm high x 214mm wide x 369mm deep (31/2 in. x 81/2 in. x 141/2 in.). Net Weight: <4.2kg (<9.2 lbs.). Shipping Weight: <9.1kg (<20 lbs.). STANDARDS EMI/RFI: Conforms to European Union EMC directive. Safety: Conforms to European Union Low Voltage directive. Note 1: For MIL-T-28800E, applies to Type III, Class 5, Style E. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Model 2001 and 2002 specifications Ohms Notes TWO-WIRE AND FOUR-WIRE OHMS