Specifications are subject to change without notice. - 1 - First issue: May. 2003 Rev.1: Mar. 2004
No. SS2-MTG200-0100 (Rev.1)
MagneW Two-wire PLUS
Smart Two-wire Electromagnetic Flowmeter
Model MTG18A (Integral type)
Model MTG14C/MTG18B (Remote type)
Integral type
Remote type
OVERVIEW
The MagneW Two-wire PLUS is a high perfor-
mance electromagnetic flowmeter based on field
proven Yamatake two-wire loop powered tech-
nology . The MagneW Two-wire PLUS offers the
stable and accurate measurement of a traditional
magflow meter with low power consumption.
The result is a lower overall cost of ownership.
FEATURES
Two-wire operation
MagneW Two-wire PLUS significantly reduces
installation costs when compared to a traditional
four wired magnetic flowmeter.
High accuracy and stable output
MagneW Two-wire PLUS provides high accu-
racy (± 0.5% of rate) and its output is as stable as
current four wired magnetic flowmeters.
Minimum measurable fluid conductivity
The MagneW Two-wire PLUS offers a mini-
mum process fluid conductivity of 10 µS/cm
which is the best among two-wire magflow
meters thereby maximizing applicability.
Wider range in size
MagneW Two-wire PLUS offers wider range in
detector size.
Detector size: 2.5 to 200 mm.
Wafer and flange style, integral and
remote style available
The MagneW Two-wire PLUS is available inte-
gral or remote. Flange or wafer, making the
selection of the right meter for the application
simple.
APPLICATION
(1) Corrosive liquid measurement
(2) Chemical solution measurement
(3) Drainage/waste disposal fluid measurement
(4) Drinking water and waste water service
(5) Industrial/agricultural water measurement
(6) Seawater measurement
The above flow measurements are applicable.
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 2 -
FUNCTIONAL SPECIFICATIONS
Enclosure rating
NEMA TYPE 4X, IEC IP67
Hazardous Areas certifications
The following is planned to make approval applications.
FM CL I,II,III, DIV 1, Groups A,B,C,D,E,F&G,T4
FM NI for CL I,II,III, DIV 2, GPs A,B,C,D,F&G, T4
Output signal
Analog output
4 to 20mA DC
Digital output
DE
Analog or Digital output is selectable.
Pulse output
Open collector output (30V DC, 100 mA max.)
Pulse frequency: 0.0001 to 200 Hz
Pulse width: 1 ms to 1 s
Contact output
Open collector output (30V DC, 100 mA max.)
Pulse or contact output is selectable
Communication protocol
SFC communication and HART® communication
Load resistance characteristic of communi-
cation
External power supply 21.05 to 42V DC for com-
munication.
Note) The load resistance of 250
or more is
necessary for communications of SFC and
the HART® communicator.
Flow unit
Volume flow: m3, L, cm3, G (gallon), mG, kG,
B (barrel), IG (imperial gallon), mIG,
kIG
Mass flow: t, kg, g, lb
Time: d, h, m, s
Display
Display: LCD
Main display: 7-segment, 8 di gits
Sub display: 16 digi ts, 2 lines
Display contents:
Demonstrates three values simultaneously
% flow rate, Actual flow rate, Totalized value
Data setting
Operation by four key switches
Damping
Adjustable between 0.5 and 199.9 seconds.
Low flow cutoff
Adjustable between 0 and 10% of setting range.
Below selected value, output is driven to the zero
flow rate signal level.
Dropout
Adjustable between 0 and 10% of setting range.
Below selected value, pulse output is cut.
Lightning protection
12 kV, 1000A
Equipped with the lightning arrester in the power
source and external output terminals.
Power failure
An EEPROM retains data record of totalized value
when pulse output is used (retention period approxi-
mately 10 years).
Power supply
15.6 to 42V DC (without communication)
21.05 to 42V DC (with communication)
Size
Wafer style
25, 40, 50, 65, 80, 100 mm (1, 1½, 2, 2½, 3, 4 inches)
Flange style
2.5, 5 mm (0.1, 0.2 inch) (Model MTG18A only)
10, 15, 25, 40, 50, 65, 80, 100, 150, 200 mm (3/8,
1/2, 1, 1½, 2, 2½, 3, 4, 6, 8 inches)
Flange rati ng
ANSI150, ANSI300, DIN PN10, DIN PN16, DIN
PN25, JIS10K, JIS20K, JIS30K
Ambient temperature limits
-20 to 60°C (-4 to 140°F)
Ambient humidity limits
10 to 90% RH
R=
Load resistance ()
Power supply (V DC )
0.0218
V-15.6
21.05<V<301
R= 0.02383
V-14.25
30<V<422
2
1
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 3 -
Temperature range and pressure range of process fluid
Refer to the following.
Measurable electrical conductivity
10 µS/cm or greater
50 µS/cm or greater (10 mm (3/8 inch), 15 mm (1/2 inch) for remote type)
Measurement flow range
Velocity V (m/s) = K × QK = Conversion factor = 1/3600 × 4/(
π
D2) × 10002
D = Size (mm)
Q = Flow rate (m3/h)
PERFORMANCE SPECIFICATIONS
Analog output accuracy
<Size: 2.5, 5 mm (0.1, 0.2 inch)> Vs = velocity of setting range (m/s)
<Size: 10, 15 mm (3/8, 1/2 inch)> Vs = velocity of setting range (m/s)
<Size: 25 to 200 mm (1 to 8 inches)> Vs = velocity of setting range (m/s)
Size: 2.5 to 10 mm (0.1 to 3/8 inch) Size: 15 to 200 mm (1/2 to 8 inches)
Size Maximum flow velocity range is
0 to 0.3 m/s (0 to 0.98 ft/s) Maximum flow velocity range is
0 to 10 m/s (0 to 32.8 ft/s) Conversion
factor K
Minimum range Maximum range
mm inches m3/h GPM m3/h GPM
2.5 0.1 0 to 0.00531 0 to 0.02335 0 to 0.1767 0 to 0.778 56.59
5 0.2 0 to 0.02121 0 to 0.09337 0 to 0.7068 0 to 3.112 14.15
10 3/8 0 to 0.08483 0 to 0.3735 0 to 2.827 0 to 12.44 3.537
15 1/2 0 to 0.1909 0 to 0.8404 0 to 6.361 0 to 28.01 1.572
25 1 0 to 0.5302 0 to 2.335 0 to 17.67 0 to 77.80 0.5659
40 0 to 1.358 0 to 5.976 0 to 45.23 0 to 199.1 0.2210
50 2 0 to 2.121 0 to 9.337 0 to 70.68 0 to 311.2 0.1415
65 0 to 3.584 0 to 15.78 0 to 119.4 0 to 525.9 0.08371
80 3 0 to 5.429 0 to 23.90 0 to 180.9 0 to 796.7 0.05526
100 4 0 to 8.483 0 to 37.35 0 to 282.7 0 to 1244 0.03537
150 6 0 to 19.09 0 to 84.04 0 to 636.1 0 to 2801 0.01572
200 8 0 to 33.93 0 to 149.4 0 to 1130 0 to 4979 0.008842
Vs (m/s) Velocity during measurement > Vs×50% Velocity during measurement < Vs×50%
±0.5% of rate ±0.5% of Vs
±% of rate ±%
Vs (m/s) Velocity during measurement > Vs×40% Velocity during measurement < Vs×40%
±0.5% of rate ±0.5% of Vs
±% of rate ±%
Vs (m/s) Velocity during measurement > Vs×30% Velocity during measurement < Vs×30%
±0.5% of rate ±0.5% of Vs
±% of rate ±%
2.94 MPa
(426 psi)
1.96 MPa
(284 psi)
-0.098 MPa
(-14.2 psi)
-20 C
(-4 F)
80 C
(176 F)
100 C
(212 F)
2.94 MPa
(426 psi)
-0.098 MPa
(-14.2 psi)
0.98 MPa
(142 psi)
-20 C
(-4 F)
80 C
(176 F)
120 C
(248 F)
130 C
(266 F)
1.0 Vs 10≤≤
0.3 Vs 1.0≤≤ 0.5
Vs
------- 0.5 0.5
Vs
-------


1.0 Vs 10≤≤
0.3 Vs 1.0≤≤ 0.5
Vs
------- 0.4 0.5
Vs
-------


1.0 Vs 10≤≤
0.3 Vs 1.0≤≤ 0.5
Vs
------- 0.3 0.5
Vs
-------


No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 4 -
PHYSICAL SPECIFICATIONS
Converter case finishing
Standard
Baked acryl pa int
Corrosion-proof
Baked epoxy paint
Converter case material
Aluminum alloy
Display cover material
Tempered glass
Terminal box finishing (Model MTG18B only)
Standard
Baked acryl pa int
Corrosion-proof
Baked epoxy paint
Terminal box material (Model MTG18B only)
Aluminum alloy
Detector main body materials
Case material
Size 2.5 to 15 mm (0.1 to 1/2 inch):
SCS13 stainless steel
Size 25 to 200 mm (1 to 8 inches):
SUS304 stainless steel
Measuring pipe material
SUS304 stainless steel
Flange
SUS304 stainless steel (size 2.5 to 65 mm (0.1 to
2½ inches))
Carbon steel + corrosion-preventive painting (size
80 to 200 mm (3 to 8 inches))
Process wetted materials
Lining
PFA
Electrode
SUS316L, Hastelloy C, Titanium, Tantalum,
Nickel, Zirconium, Platinum-Iridium
Grounding ring
SUS316, Hastelloy C, Titanium, Tantalum, Zirco-
nium, Platinum
INSTALLATION
Electrical connection
1/2NPT internal thread (must be selected for FM
approval)
CM20 internal thread
G1/2 internal thread
Remote converter mounting
Wall mounting, 2-inch pipe mounting
Grounding
Grounding resistance should be less than 100 .
Pipe connection
Wafer style (Size: 25 to 100 m m (1 to 4 inches))
Flange style (Size: 2.5 to 200 mm (0.1 to 8 inches))
Length of straight pipe
Required straight pipe length clearance on the
upstream side and the downstream side, while install-
ing the detector.
Upstream side
A minimum 5D straight pipe length is required.
A minimum 10D straight pipe length is required if a
diffuser/valve/pump is installed upstream side.
Downstream side
2D straight pipe length is recommended.
(Where D is the nominal bore diameter of the
detector)
Cable between converter and detector
(Remote type)
Length
70 m (233 ft) or under
(25 mm (1 inch) to 200 mm (8 inches))
30 m (98 ft) or under
(10 mm (3/8 inch), 15 mm (1/2 inch))
Outside diameter
11.4 mm (0.45 inch)
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 5 -
MODEL SELECTION
MagneW Two-wire PLUS
Model MTG18A - I II III IV V VI VII VIII IX X XI - XII XIII - Options (some options can be selected per each model)
Basic model no. Selections Optional selectionsOptions
MTG18A --
I Line size 2.5 mm (0.1 inch) (flange type only) 002 *1 X None
Options
5 mm (0.2 inch) (flange type only) 005 *1 A Test report
10 mm (3/8 inch) (flange type only) 010 *1 B Traceability cer ti fi cat e
15 mm (0.5 inch) (flange type only) 015 *1 C Material certificate (elec-
trode/grounding ring)
25 mm (1 inch) 025
40 mm (1½ inches) 040 G Gasket for plastic piping
50 mm (2 inches) 050 J Tropical treatment
65 mm (2½ inches) 065 K with tagging on the converter
housing *3
80 mm (3 inches) 080
100 mm (4 inches) 100 L with tag number plate wired
to the flowmeter
150 mm (6 inches) (flange type only) 150
200 mm (8 inches) (flange type only) 200
II Lining PFA P X Finish /
paint XII
III Pipe connec-
tion Wafer JIS10K 11 2 Corrosion-proof finish
Wafer JIS16/20K 12
Wafer JIS30K 13 X Bolt and
nut None XIII
Wafer ANSI 150 21 2 SUS304 (only for wafer type)
Wafer ANSI 300 22
Wafer DIN PN10 41
Wafer DIN PN16 42
Wafer DIN PN25 43
Wafer DIN PN40 44
Flange JIS10K J1
Flange JIS20K J2
Flange JIS30K J3
Flange JIS10K for 10 mm size flange *2 J4
Flange JIS20K for 10 mm size flange *2 J5
Flange ANSI 150 A1
Flange ANSI 300 A2
Flange DIN PN10 D1
Flange DIN PN16 D2
Flange DIN PN25 D3
Flange DIN PN40 D4
IV Electrode SUS316L L
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Nickel N
Platinum-iridium P
V Grounding
ring SUS316 S
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Note) *1: Flange of size 2.5 to 15 mm detector
is 15 mm flange.
*2: Available for size 2.5 to 10 mm detec-
tor.
*3: Must be selected if tagging is
required.
Platinum P
Nickel N
VI Wiring con-
nection G1/2 internal thread A
G1/2 internal thread with plastic water tight gland B
G1/2 internal thread with brass Ni-plated watertight gland C
1/2NPT internal thread (must be selected for FM approval) D
CM20 internal thread E
G1/2 internal thread with two plastic watertight glands J
G1/2 internal thread with two brass Ni-plated watertight gland
K
VII Face to face
dimension Standard A
Replacement for SMT3000 (for wafer type 40 to 100 mm) S
VIII Installation /
Display
direction
Horizontal piping / Right side viewed from upstream A
Horizontal piping / Left side viewed from upstream B
Horizontal piping / Downstream side C
Horizontal piping / Upstream side D
Vertical piping / Right side of piping / Flow direction: Upward E
Vertical piping mounting / Left side of piping / Flow direction: Upward F
IX Calibration Standard A
X Output /
communica-
tion
Volume flow 4-20mA DC output/with SFC communication A
Volume flow DE output/with communication C
Volume flow 4-20mA DC output with HART communication H
XI Approval None X
FM approval, CL I, II, III, DIV.1, GPs A, B, C, D, E, F & G, T4 1
FM approval, CL I, II, III, DIV.2, GPs A, B, C, D, F & G, T4 2
Direction
of flow
Direction
of flow
Direction
of flow Direction
of flow
Direction
of flow
Direction
of flow
Display direction code "A" Display direction code "B"
Display direction code "C" Display direction code "D"
Display direction code "E" Display direction code "F"
Display
Display Display
Display
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 6 -
MagneW Two-wire PLUS Wafer/Flange remote type converter
Model MTG14C - I II III IV - Options (some op tions can be selected per each model)
Basic model no. Selections
MagneW Two-wire PLUS Wafer/Flange remote type cable
Model SMC11 - I II III
Basic model no. Selections
MTG14C
I Analog output / communication Volume flow 4-20 mA DC output / with SFC communication A
Volume flow DE output / with communication C
Volume flow 4-20 mA DC output / with HART communication H
II Wiring connection G1/2 internal thread A
G1/2 internal thread with a plastic water-tight gland B
G1/2 internal thread with a brass Ni-plated water-tight gland C
1/2NPT internal thread D
CM20 internal thread E
III Converter mounting Wall mounting with standard bracket G
2-inch pipe mounting with standard bracket H
IV Approval None X -
V Option None X
Traceability ce rtificate B
With the Tag number plate on the converter housing K
Corrosion-proof paint 2
SMC11
I Cable 2 m (6 feet 8 inches) 02
3 m (10 feet) 03
4 m (13 feet 4 inches) 04
5 m (16 feet 8 inches) 05
10 m (33 feet 4 inches) 10
15 m (50 feet) 15
20 m (66 feet 8 inches) 20
30 m (100 feet) 30
40 m (133 feet 4 inches) 40
50 m (166 feet 8 inches) 50
60 m (200 feet) 60
70 m (233 feet 4 inches) 70
II Terminals for detector With terminals A
III Terminals for converter With terminals A
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 7 -
MagneW Two-wire PLUS Wafer/Flange remote type detector
Model MTG18B - I II III IV V VI VII VIII IX - Options (some options can be selected per each model)
Basic model no. Selections Options
MTG18B
I Diameter 10 mm (3/8 inch) 010 XNone
Options
15 mm (1/2 inch) 015 A Test report
25 mm (1 inch) 025 B T raceability certificate
40 mm (1½ inches) 040 C Material certificate (electrode/ ground-
ing ring)
50 mm (2 inches) 050
65 mm (2½ inches) 065 G Gasket for plastic piping
80 mm (3 inches) 080 K With the Tag number plate on the termi-
nal box
100 mm (4 inches) 100
150 mm (6 inches) 150 2 Corrosion-proof paint
200 mm (8 inches) 200 4 Attached stainless steel 304 bolts and
nuts for installation *1
II Lining PFA P
III Pipe con-
nection Wafer JIS10K 11 *1: Available for wafer type.
Wafer JIS16/20K 12
Wafer JIS30K 13
Wafer JIS 3451 F12 (Size: 80 mm or larger) 51
Wafer ANSI 150 21
Wafer ANSI 300 22
Wafer JPI 150 61
Wafer JPI 300 62
Wafer DIN PN10 41
Wafer DIN PN16 42
Wafer DIN PN25 43
Flange JIS10K J1
Flange JIS20K J2
Flange JIS30K J3
Flange JIS10K for 10 mm size flange J4
Flange JIS20K for 10 mm size flange J5
Flange JIS3451 F12 (Size: 80 mm or larger) G1
Flange ANSI 150 A1
Flange ANSI 300 A2
Flange JPI 150 P1
Flange JPI 300 P2
Flange DIN PN10 D1
Flange DIN PN16 D2
Flange DIN PN25 D3
IV Electrode SUS316L L
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Nickel N
Platinum-iridium P
V Grounding
ring SUS316 S
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Platinum P
VI Wiring con-
nection G1/2 internal thread A
G1/2 internal thread with plastic water-tight gland B
G1/2 internal thread with brass Ni-plated water-tight gland C
1/2NPT internal thread D
CM20 internal thread E
VII Face to face
dimension Standard A
Yamatake SMT3000 wafer type S
VIII
Calibration Standard calibration A
IX Approval None X
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 8 -
DIMENSIONS
All dimensions are in millimeters, dimensions in brackets ( ) are in inches (inch).
Model MTG18A - Flange type size 2.5 mm (0.1 inch) to 15 mm (1/2 inch)
- Flange type size 25 mm (1 inch)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 1
Size mm
(inch)
Model no. J1 J2 J3 J4 J5 A1 A2 D1/D2 D3/D4
Flange rating JIS ANSI DIN
10K 20K 30K 10K
10 mm flange 20K
10 mm flange 150 300 PN 10/16 PN 25/40
2.5 to 10
(0.1 to3/8) Dimension L 160 160 160 160 160 1 60 (6.3) 160 (6.3) 160 160
Weight (kg) 6.8 7 8 6.7 6.8 6.4 (14.1 lb) 6.9 (15.2 lb) 6.9 7.1
15
(1/2) Dimension L 200 200 200 20 0 200 200 (7.87) 200 (7.87) 200 200
Weight (kg) 7 7.2 8.2 6.9 7 6.6 (14.6 lb) 7.1 (15.7 lb) 7.1 7.3
25
(1) Dimension H267 267 269 - - 258 (10.16) 266 (10.47) 262 262
H1 63 63 65 - - 54 (2.13) 62 (2.44) 58 58
Weight (kg) 9.2 9.5 10.3 - - 8.4 (18.5 lb) 9.5 (20.9 lb) 9.1 9.4
( )
Case
M4 Grounding
terminal
Electrode
Flange
Name plate
( 0.35 ( 2)) Refer to Note 1
L
Grounding ring
(5.33)
(3.37)
(1.97)
(1.85)
(0.98)
(2.76)
(3.54)
(4.33)
(0.08)
(10.63)
(2.83)
(5)
(2.80)
( 4.41)
(5.35) Flange type
Size 2.5 mm to 15 mm
(0.1 inch to 1/2 inch)
Flange type
Size 25 mm
(1 inch )
Symbol Description
Flow rate
signal
Grounding
Pulse output or
contact output
(selectable)
Terminal
Case
M4 Grounding
terminal
Electrode
Flange
Name plate
Refer to Note 1
Grounding
ring
(7.87)
(5.35)
(0.98)
(2.76)
(5.33)
(3.37)
(1.85)
(1.97)
( 4.41)
(5)
(3.03)
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 9 -
Model MTG18A - Flange type size 40 mm (1½ inch) to 100 mm (4 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316 , a 3 mm of Teflon gasket dimen sion is included
to the face-to-face dimension.
Table 2
Size mm
(inches)
Model no. J1 J2 J3 A1 A2 D1/D2 D3/D4
Flange rating JIS ANSI DIN
10K 20K 30K 150 300 PN 10/16 PN 25/4 0
40
(1.5) Dimension H296 296 307 288 (11.34) 305 (12.01) 302 302
H1 85 85 96 77 (3.03) 94 (3.7) 91 91
H2 84 84 84 84 (3.31) 84 (3.31) 84 84
Weight (kg) 8.3 8.6 11 7.8 (17.2 lb) 10.1 (22.3 lb) 8.7 9.7
50
(2) Dimension H310 310 316 308 (1 2.13) 316 (12.44) 316 316
H1 90 90 96 88 (3.46) 96 (3.78) 96 96
H2 93 93 93 93 (3.66) 93 (3.66) 93 93
Weight (kg) 11.9 12 13.7 12.3 (2 7.1 lb) 13.8 (30.4 lb) 13.3 13.8
65
(2.5) Dimension H329 329 343 330 (1 2.99) 388 (13.31) 334 334
H1 102 102 116 103 (4.06) 111 (4.37) 107 107
H2 100 100 100 100 (3.94) 100 (3.94) 100 100
Weight (kg) 13.9 14 15.7 14 .3 (31.5 lb) 15.8 (34 . 8 lb) 15.3 15.8
80
(3) Dimension H345 354 359 346 (1 3.62) 359 (14.13) 354 354
H1 110 119 124 113 (4.45) 124 (4.88) 119 119
H2 108 108 108 108 (4.25) 108 (4.25) 108 108
Weight (kg) 14.4 16.7 20.4 17.3 (38.1 lb) 21.3 (47.0 lb) 14.4 16.5
100
(4) Dimension H367.5 376.5 384.5 378.5 (14.90 ) 392.5 (15.45) 373.5 381.5
H1 120 129 137 131 (5.16) 145 (5.71) 126 134
H2 120.5 1 20.5 120.5 120.5 (4.74) 120.5 (4.74) 1 20.5 120.5
Weight (kg) 20.2 23.7 28.6 25.1 (55.3 lb) 34.2 (75.4 lb) 19.6 23.4
Case
M4 Grounding
terminal
Electrode
Flange
Name plate
Refer to Note 1
Grounding
ring
(5.33)
(5)
(3.37)
(1.85)
(1.97)
(0.98)(2.76)
( 4.41)
(5.35)
(7.87)
Symbol Description
Flow rate
signal
Grounding
Pulse output or
contact output
(selectable)
Terminal
Flange type
Size 40 mm to 100 mm
(11/2 inch to 4 inches)
H2
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 10 -
Model MTG18A - Flange type size 150 mm (6 inches) and 200 mm (8 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included
to the face-to-face dimension.
Table 3
Size mm
(inches)
Model no. J1J2J3 A1 A2 D1/D2D3 D4
Flange rating JIS ANSI DIN
10K 20K 30K 150 300 PN 10/16 PN 25 PN40
150
(6)
Dimension L 300 300 300 300 (11.81) 300 (11.81) 300 300 300
H462 476 487 461 (18.15) 483 (19.02) 465 473 473
H1 175 189 200 174 (6.85) 196 (7.72) 178 186 186
H2 160 160 160 160 (6.3) 160 (6.3 ) 160 160 160
Weight (kg) 34.4 41.7 54.3 37.2 (82.0 lb) 56.2 (123.9 lb) 30.7 38.6 38.6
200
(8)
Dimension L 350 350 350 350 (13.78) 350 (13.78) 350 350 350
H508 515 531 516 (20.31) 537 (21.14) 514 526 534
H1 196 203 219 204 (8.03) 225 (8.86) 202 214 222
H2 185 185 185 185 (7.28) 185 (7.28) 185 185 185
Weight (kg) 49.8 59.8 87 61.8 (136.2 lb) 90.8 (200.2 lb) 48.1 68.5 72
Flange type
Size 150 mm and 200 mm
(6 inches and 8 inches)
Symbol Description
Flow rate
signal
Grounding
Pulse output or
contact output
(selectable)
Terminal
Case
M4 Grounding
terminal
Electrode
Flange
Refer to Note 1
Grounding
ring
L
(5.33)
(3.37)
(1.85)
(1.97)
(0.98)
(2.76)
H2
( 4.41)
(5)
(5.35)
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 11 -
Model MTG18A - Wafer type size 25 mm (1 inch) to 100 mm (4 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316 , a 3 mm of Teflon gasket dimen sion is included
to the face-to-face dimension.
Table 4
Flange rating 25 mm
(1 inch) 40 mm
(1½ inch) 50 mm
(2 inches) 65 mm
(2½
inches)
80 mm
(3 inches) 100 mm
(4 inches)
Face-to-face
dimension code AASAS A ASAS
Dimension
size
L94 (3.7)
80 (3.15) 98 (3.86) 86 (3.39)
104 (4.09)
96 (3.78)
106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91)
H238 (9.37) 254.5 (10.02) 272 (10.71) 289 (11.38) 302 (11.89) 327 (12.87)
H1 34 (1.34) 43.5 (1.71) 52 (2.05) 62 (2.44) 67 (2.64) 79.5 (3.13)
H2 77 (3.03) 84 (3.31) 93 (3.66) 100 (3.94) 108 (4.25) 120.5 (4.74)
D68 (2.68) 87 (3.43) 104 (4.09) 124 (4.88) 134 (5.28) 159 (6.26)
Weight (kg) 3.7
(8.2 lb) 3.8
(8.4 lb) 4.3
(9.5 lb) 4.4
(9.7 lb) 5.0
(11.0 lb) 5.5
(12.1 lb) 6.4
(14.1 lb ) 7.1
(15.7 lb ) 8.2
(18.1 lb ) 9.2
(20.3 lb)
Wafer type
Size 25 mm and 100 mm
(1 inch and 4 inches)
Symbol Description
Flow rate
signal
Grounding
Pulse output or
contact output
(selectable)
Terminal
Name plate
M4 grounding
terminal
Case
Electrode L
Refer to note1
Grounding
ring
(5.33)
(3.37)
(1.97)
(1.85)
(0.98)
(2.76)
( 4.41)
D
(5)
H
(H1) H2
(5.35)
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 12 -
Model MTG14C - Converter
Wall mounting dimension
Wall mounting
Plate
Terminal
Symbol Description
I-OUT
PULSE/
STATUS
OUT
X
Y
A
B
C
Flow rate signal
Grounding
Pulse output
or contact
(selectable)
Excitation output
Flow rate
signal input
2-inch pipe mounting
* Terminal screw: M4
(R0.16)
(0.75)
(R0.49)
(R0.31)
(10.67 )
+0.04
0
(R0.49)
(R0.49)
(2.91+0.02)
(0.77)
(4.41)
(4.41)
(10.12)(10.12)
(0.63)
(0.63)
(1.19 max.)(1.19 max.)
(4.36)
(2.74)
(4.36)
(2.74)
(9.92)
(1.77) (1.77)
(4.92)
(1.77) (1.77)
(3.63)
(3.63)
(0.13)
(1.23)
(6.30)
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 13 -
Model MTG18B - Detector - Flange type size 10 mm (3/8 inch) and 15 mm (1/2 inch)
- Flange type size 25 mm (1 inch)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316 , a 3 mm of Teflon gasket dimen sion is included
to the face-to-face dimension.
Table 5
Size mm
(inches)
Model no. J1J2J3 J4 J5 A1 A2 D1/D2D3/D4
Flange rating JIS ANSI DIN
10K 20K 30K 10K
10 mm flange 20K
10 mm flange 150 300 PN 10/16 PN 25/40
10
(3/8) Dimension L 160 160 160 160 160 160 (6.3) 160 (6.3) 160 160
Weight (kg) 5 5.2 6.2 4.9 5 4.6 (10.1 lb) 5.1 (11.2 lb) 5.1 5.3
15
(1/2) Dimension L 200 200 200 2 00 200 200 (7.87) 200 (7.87) 200 200
Weight (kg) 5.2 5.4 6.4 5.1 5.2 4.8 (10.6 lb) 5.3 (11.7 lb) 5.3 5.5
25
(1) Dimension H187 187 189 - - 188 (7.4) 186 (7.32) 182 182
H1 63 63 65 - - 54 (2.13) 62 (2.44) 58 58
Weight (kg) 7.4 7.7 8.5 - - 6.6 (14.6 lb) 7.7 (17.0 lb) 7.3 7.6
9 ( 2)
0.35 ( 2)
()
Waterproof gland
Terminal box
Tag plate
Nameplate
Grounding ring
Electrode
(3.31)
(0.98)
(3.31)
(1.19 max.)
(7.48)
(1.85)
(2.80)(2.83)
(0.08)
(2.05)
(4.43)
(4.43)
(3.54)
(3.31)
(optional)
Waterproof gland
(optional)
Symbol Description
Excitation input
Flow rate signal
output
Grounding
* Terminal screw: M4
X
Y
A
B
C
Terminal
Flange type
Size 10 mm and 15 mm
(3/8 and 1/2 inch)
Flange type
Size 25 mm (1 inch)
(1.85)
(3.03)
Terminal box
Tag plate
Nameplate
Grounding ring
(1.19 max.)
(3.31)
(0.98)
Blind plug
Blind plug
(7.89)
H
H1
Electrode
Refer to note 1
Refer to note 1
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 14 -
Model MTG18B - Detector - Flange type size 40 mm (1½ inch) to 100 mm (4 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included
to the face-to-face dimension.
Table 6
Size mm
(inches)
Model no. J1J2J3 A1 A2 D1/D2D3/D4
Flange rating JIS ANSI DIN
10K 20K 30K 150 300 PN 10/16 PN 25/40
40
(1.5) Dimension H216 216 227 208 (8.19) 225 (8.86) 222 222
H1 85 85 96 77 (3.03) 94 (3.7) 91 91
H2 84 84 84 84 (3.31) 84 (3.31) 84 84
Weight (kg) 6.5 6.8 9.2 6 (13.2 lb) 8.3 (18.3 lb) 6.9 7.9
50
(2) Dimension H230 230 236 228 (8.98) 236 (9.29) 236 2 36
H1 90 90 96 88 (3.46) 96 (3.78) 96 96
H2 93 93 93 93 (3.66) 93 (3.66) 93 93
Weight (kg) 10.1 10.2 11.9 10.5 (23.1 lb) 12 (26.5 lb) 11.5 12
65
(2.5) Dimension H249 2 49 263 250 (9.84) 258 (10.16) 254 254
H1 102 102 116 103 (4.06) 111 (4.37) 107 107
H2 100 100 100 100 (3.94) 100 (3.94) 100 1 00
Weight (kg) 12.1 12.2 13.9 12.5 (27.6 lb) 14 (30.9 lb) 13.5 14
80
(3) Dimension H265 274 279 266 (10.47) 279 (10.98) 274 274
H1 110 119 124 113 (4.45) 124 (4.88) 119 1 19
H2 108 108 108 108 (4.25) 108 (4.25) 108 1 08
Weight (kg) 16.6 14.9 18.6 15.5 (34.2 lb) 19.5 (43.0 lb) 12.6 14.7
100
(4) Dimension H287.5 296.5 304.5 298.5 (11.75) 312.5 (12.30) 293.5 301.5
H1 120 129 137 131 (5.16) 145 (5.71) 126 1 34
H2 120.5 120.5 120.5 120.5 (4.74) 120.5 (4.74) 120.5 12 0.5
Weight (kg) 18.4 21.9 26.8 23.3 (51.4 lb) 32.4 (71.4 lb) 17.8 21.6
Case
Electrode
Flange
Refer to Note 1
Grounding
ring
(7.87)
(1.19 max.) (3.31)
(3.31)
Nameplate
Tag plate
Terminal box
Waterproof gland
(optional)
H2
(1.85)
Symbol Description
Excitation input
Flow rate signal
output
Grounding
* Terminal screw: M4
X
Y
A
B
C
Terminal
Flange type
Size 40 mm to 100 mm
(11/2 inch to 4 inches)
(0.98)
Blind plug
Yamatake Corporation No. SS2-MTG200-0100 (Rev.1)
- 15 -
Model MTG18B - Detector - Flange type size 150 mm (6 inches) and 200 mm (8 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316 , a 3 mm of Teflon gasket dimen sion is included
to the face-to-face dimension.
Table 7
Size mm
(inches)
Model no. J1J2J3 A1 A2 D1/D2D3D4
Flange rating JIS ANSI DIN
10K 20K 30K 150 300 PN 10/16 PN 25 PN 40
150
(6) Dimension
L300 300 300 300 (11.81) 300 (11.81) 300 300 300
H382 396 40 7 381 (15) 403 (15.87) 385 393 393
H1 175 189 200 174 (6.85) 196 (7.72) 178 186 186
H2 160 160 160 160 (6.3) 160 (6.3) 160 160 160
Weight (kg) 32.6 39.9 52.5 35.4 (78 lb) 54.4 (119.9 lb) 28.9 36.8 36.8
200
(8) Dimension
L350 350 3 50 350 (13.7 8) 350 (13.78) 350 350 350
H428 435 4 51 436 (17.1 7) 457 (17.99) 434 446 454
H1 196 203 219 204 (8.03) 225 (8.86) 202 214 222
H2 185 185 185 185 (7.28) 185(7.28) 185 185 185
Weight (kg) 48 58 85.2 60 (132.3 lb) 89 (196.2 lb) 46.3 66.7 70.2
H2
Case
Electrode
Flange
Refer to Note 1
Grounding
ring
L
Symbol Description
Excitation input
Flow rate signal
output
Grounding
* Terminal screw: M4
X
Y
A
B
C
Terminal
Flange type
Size 150 mm and 200 mm
(6 inches and 8 inches)
(1.19 max.) (3.31)
Nameplate
Tag plate
Terminal box
Waterproof gland
(optional)
(3.31)
(1.85)
(0.98)
Blind plug
No. SS2-MTG200-0100 (Rev.1) Yamatake Corporation
- 16 -
Model MTG18B - Detector - Wafer type size 25 mm (1 inch) to 100 mm (4 inches)
Note 1 When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included
to the face-to-face dimension.
Table 8
Flange rating 25 mm
(1 inch) 40 mm
(1½ inch) 50 mm
(2 inches) 65 mm
(2½ inches) 80 mm
(3 inches) 100 mm
(4 inches)
Face-to-face
dimension code A ASAS A ASAS
Dimen-
sion size
L94 (3.7)
80 (3.15) 98 (3.86) 86 (3.39)
104 (4.09)
96 (3.78)
106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91)
H158 (6.22) 174.5 (6.87) 192 (7.56) 209 (8.23) 222 (8.74) 2 47 (9.72)
H1 34 (1.34) 4 3.5 (1.71) 52 (2.05) 62 (2.44) 67 (2.64) 79.5 (3.13)
H2 77 (3.03) 84 (3.31) 93 (3.66) 100 (3.94) 108 (4.25) 120.5 (4.74)
D68 (2.68) 87 (3.43) 104 (4.09) 124 (4.88) 134 (5.28) 159 (6.26)
Weight (kg) 2
(4.4 lb) 2
(4.4 lb) 2.5
(5.5 lb) 2.6
(5.7 lb) 3.2
(7.1 lb) 3.7
(8.2 lb) 4.6
(10.1 lb ) 5.3
(11.7 lb) 6.4
(14.1 lb ) 7.4
(16.3 lb )
Symbol Description
Excitation input
Flow rate signal
output
Grounding
* Terminal screw: M4
X
Y
A
B
C
Terminal
Wafer type
Size 25 mm to 100 mm
(1 inch to 4 inches)
Waterproof gland
(optional)
Terminal box
Tag plate
Nameplate
Grounding ring
Electrode
(1.19 max.)
(3.31)
(3.31)
(1.85)
Refer to Note 1
D
(0.98)
Case
Blind plug
2-12-19 S
hib
u
ya
Shib
u
y
a-
k
u, To
ky
o 150-831
6
J
a
p
an
Tel
:
Fax
:
81
-
3
-
3486
-
2310
81
-
3
-
3486
-
2593
This has been printed on rec
y
cled paper
.
http://www.
amatake.com
S
avemation
Savin
g
t
h
rou
gh
Automatio
n