AC-DC
Specification
45-130 Watts
•Output Voltages from 2.5 V to 48 V
•Non-standard Outputs Available
•Universal Input
•Single & Multiple Output Versions
•0 °C to +70 °C Operating Temperature
•Efficiency up to 80%
•Non-standard Connectors Available
AEH Series
Input
Input Voltage • 90-264 VAC
Input Frequency • 47-63 Hz
Input Current • 1.5/0.7 A for AEH45, at 115/230 VAC
1.9/1.5 A for AEH80, at 115/230 VAC
3.2/1.7 A for AEH130, at 115/230 VAC
Inrush Current • AEH45 & 80: 30 A max at 230 VAC
AEH130: 60 A max at 230 VAC
cold start
Power Factor • EN61000-3-2 class A
Earth Leakage Current • <0.5 mA max at 115 VAC/60 Hz
<0.75 mA max at 230 VAC/50 Hz
Output
Output Voltage • See tables. Factory set non-standard
voltages available - contact sales
Initial Set Accuracy •5%
Start Up Delay • 2 s max
Hold Up Time • 16 ms min (>50 ms AEH130)
Line Regulation • See note 2
Load Regulation • See note 2
Transient Response • 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise • 2% pk-pk for outputs ≤3.3 V
1% pk-pk for all other outputs
20 MHz BW
Overvoltage Protection • 112-132% Vnom, auto reset
Overload Protection • Output 1 only 110-150% of nominal
Temperature • ±0.04%/°C max
Coefficient
xppower.com
General
Efficiency • Up to 80%
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 67-83 kHz for AEH45
58 kHz typical for AEH80
53-76 kHz for AEH130
MTBF • 100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +40 °C to 50% load at +70 °C
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Vibration • 2 g on 3 axes
EMC & Safety
Emissions • EN55022 level B, conducted and radiated
Harmonic Currents • EN61000-3-2, Class A
Voltage Flicker • EN61000-3-2
ESD Immunity • EN61000-4-2, level 2 Perf Criteria A
Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A
EFT/Burst • EN61000-4-4, level 2 Perf Criteria A
Surge • EN61000-4-5, level 3 Perf Criteria A
Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A
Dips & Interruptions • EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL60950-1,
CSA C22.2 No. 950 per cUL, CE Mark