Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC Overview Applications The C9T capacitor is a polypropylene metallized film capacitor with a cylindrical, aluminium can-type design filled with resin. It uses a 3-phase delta connection and safety device FPU. Typical applications power factor correction. Benefits * * * * * VDE Approved Overpressure safety device High capacitance density Long lifetime 3-phase delta connections Part Number System C9T S 5 M D 6137 AAR X Series Type Rated Voltage (VAC) Terminal Style Internal Connection Capacitance Code (pF) Internal Code Tolerance C9T = Cylindrical Three-Phase Capacitors S = Slim D = Delta Digits 2-4 indicate the first three digits of the capacitance value. First digit indicates the number of zeros to be added. AAR = Standard X = -5%/+10% 5 = 415 6 = 440 M = Screw clamp Terminal One world. One KEMET (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 1 Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC Dimensions - Millimeters 44 19 10 M12 10 15 48 O(D+4) O D+/-0.5 44 O7 160.5 H2 362 D H 0.5 2 Mounting Stud (M) 75 75 75 85 85 85 160 230 280 160 230 280 M12 x 16 M12 x 16 M12 x 16 M12 x 16 M12 x 16 M12 x 16 Qualifications Reference Standards Protected 10,000 AFC IEC 831-1/2 Approved VDE-REG.Nr.F064 -25C to +70C General Technical Data IEC 60831-1/2 Reference Standards Approved VDE-REG.Nr.F064 UL810 compliant Dielectric Polypropylene film Non-Inductive type winding -25/D - IEC 60831-1 Climatic Category Maximum: 55C Highest mean over any period of 24 hours: 45C Highest mean over any period of one year: 35C Maximum Hot Spot Temperature Endurance Test IEC 60831-2 +70C IEC 60831-2 clause 17.1-17.2 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 2 Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC Electrical Characteristics Rated Voltage Un = (see table) Vrms IEC 60831-1 clause 20: 1,10*UN - 8 hours in every 24 hours Over Voltage 1,15* UN - 30 minutes in every 24 hours 1,20* UN - 5 minutes in the lifetime 1,30* UN - 1 minutes in the lifetime Capacitance Tolerance -5% +10% (X) Mechanical Characteristics Maximum Torque: Installation 6 [N*m] for Terminal screw 12 [N*m] for M12 Bolt Whatever position Aluminum deck with self extinguishing UL94 V0 plastic cover Life Expectancy Life Expectancy Capacitance drop at end of life Failure rate IEC 61709 100,000 hours at Urms with Ths 70C -5% (typical) 300*10-9 components/hours Test Method Test voltage term to term (Utt) 2,15*Urms for 2 seconds at 25C Test voltage term to case (Utc) 3600 V - 50 Hz for 2 seconds Annual average 80% at 24C Relative Humidity On 30 days/year permanently 100%. On other days occasionally 90%. Dewing not admitted Capacitance Deviation in Temperature Range (-40..+50C) 1.5% maximum on capacitance value at 20C Damp Heat IEC 60068-2-78 Change of Temperature IEC 60068-2-14 Vibration Strength IEC 60068-2-6 NOTICE: Care should be taken to ensure that there still is electrical clearance of 15 mm between terminations and other live or earthed parts above the capacitor, in case of safety device activation. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 3 Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC Table 1 - Ratings & Part Number Reference Capacitance Value Voltage Dimensions (mm) F VAC O 3 x 31.1 3 x 46.0 3 x 61.5 3 x 77.0 3 x 92.2 3 x 108.0 3 x 123.0 3 x 154.0 3 x 27.4 3 x 41.1 3 x 54.8 3 x 68.5 3 x 83.0 3 x 96.0 3 x 110.0 3 x 137.0 415 415 415 415 415 415 415 415 440 440 440 440 440 440 440 440 75 75 85 75 85 75 75 85 75 75 85 75 85 75 75 85 Rated Current Qn Operating Frequency dV/dt H A kVAr Hz V/s 160 160 160 230 230 280 280 280 160 160 160 230 230 280 280 280 9 14 18 23 27 32 36 45 9 13 17 21 26 30 34 43 5.0 7.5 10.0 12.5 15.0 17.5 20.0 25.0 5.0 7.5 10.0 12.5 15.0 17.5 20.0 25.0 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Packaging Quantity Part Number 12 12 9 12 9 12 12 9 12 12 9 12 9 12 12 9 C9TS5MD5311AARX C9TS5MD5460AARX C9TS5MD5615AARX C9TS5MD5770AARX C9TS5MD5920AARX C9TS5MD6108AARX C9TS5MD6123AARX C9TS5MD6154AARX C9TS6MD5274AARX C9TS6MD5411AARX C9TS6MD5548AARX C9TS6MD5685AARX C9TS6MD5830AARX C9TS6MD5960AARX C9TS6MD6110AARX C9TS6MD6137AARX (*) Maximum admissible RMS current. Ths 70C. Marking Manufacturer Logo Safety Warning Self-healing Dielectric and Approval Part Number, Batch Number and Production Date Rated Reactive Power and Current Rated Voltage and Insulating Level Rated Frequency and Internal Connections Climatic Class (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 4 Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC Environmental Compliance As a leading global supplier of electronic components and an environmentally conscious company, KEMET continually aspires to improve the environmental effects of our manufacturing processes and our finished electronic components. In Europe (RoHS Directive) and in some other geographical areas such as China (China RoHS), legislation has been enacted to prevent or otherwise limit the use of certain hazardous materials, including lead (Pb), in electronic equipment. KEMET monitors legislation globally to ensure compliance and endeavors to adjust our manufacturing processes and/or electronic components as may be required by applicable law. For military, medical, automotive, and some commercial applications, the use of lead (Pb) in the termination is necessary and/or required by design. KEMET is committed to communicating RoHS compliance to our customers. Information related to RoHS compliance will be provided in data sheets and using specific identifiers on the packaging labels. All KEMET power film capacitors are RoHS compliant. Materials & Environment The selection of raw materials that KEMET uses for the production of its electronic components is the result of extensive experience. KEMET directs specific attention toward environmental protection. KEMET selects its suppliers according to ISO 9001 standards and performs statistical analyses on raw materials before acceptance for use in manufacturing our electronic components. All materials are, to the best of KEMET's knowledge, non-toxic and free from cadmium; mercury; chrome and compounds; polychlorine triphenyl (PCB); bromide and chlorinedioxins bromurate clorurate; CFC and HCFC; and asbestos. Dissipation Factor Dissipation factor is a complex function involved with capacitor inefficiency. The tg may vary up and down with increased temperature. For more information, refer to Performance Characteristics. Sealing Hermetically Sealed Capacitors As the temperature increases, the pressure inside the capacitor increases. If the internal pressure is high enough, it can cause a breach in the capacitor. Such a breach can result in leakage, impregnation, filling fluid, or moisture susceptibility. Barometric Pressure The altitude at which hermetically sealed capacitors are operated controls the capacitor's voltage rating. As the barometric pressure decreases, the susceptibility to terminal arc-over increases. Non-hermetic capacitors can be affected by internal stresses due to pressure changes. These effects can be in the form of capacitance changes, dielectric arc-over, and/or low insulation resistance. Altitude can also affect heat transfer. Heat that is generated in an operation cannot be dissipated properly, and high RI2 losses and eventual failure can result. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 5 Aluminum Can Power Film Capacitors C9T, 415 - 440 VAC, 3-Phase PFC KEMET Electronics Corporation Sales Offices For a complete list of our global sales offices, please visit www.kemet.com/sales. Disclaimer All product specifications, statements, information and data (collectively, the "Information") in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation's ("KEMET") knowledge of typical operating conditions for such applications, but are not intended to constitute - and KEMET specifically disclaims - any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET's products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com F3051_C9T_RADIAL * 3/29/2019 6