3
FUSED COUPLER, 980 NM
Insertion Loss
Coupling Grade Signal Path Tap Path
Ratio Insertion Loss1, 2 TDL3Insertion Loss1, 2 TDL3
(Min./Max.) Max. (Min./Max.) Max.
1% P NA/0.15 dB 0.02 dB 18.4/21.5 dB 0.20 dB
1% A NA/0.20 dB 0.02 dB 15.0/22.0 dB 0.20 dB
5% P NA/0.40 dB 0.08 dB 11.3/14.8 dB 0.15 dB
5% A NA/0.50 dB 0.08 dB 11.0/15.2 dB 0.15 dB
10% P NA/0.65 dB 0.08 dB 9.00/11.5 dB 0.13 dB
10% A NA/0.75 dB 0.08 dB 8.50/11.8 dB 0.13 dB
20% P NA/1.40 dB 0.10 dB 5.60/8.40 dB 0.10 dB
20% A NA/1.50 dB 0.10 dB 5.40/8.60 dB 0.10 dB
30% P NA/2.00 dB 0.10 dB 4.10/6.40 dB 0.10 dB
30% A NA/2.20 dB 0.10 dB 4.00/6.50 dB 0.10 dB
40% P NA/2.60 dB 0.10 dB 3.20/4.70 dB 0.10 dB
40% A NA/2.80 dB 0.10 dB 3.10/4.80 dB 0.10 dB
50% P 2.60/3.40 dB 0.10 dB 2.60/3.40 dB 0.10 dB
50% A 2.50/3.60 dB 0.10 dB 2.50/3.60 dB 0.10 dB
1. Insertion loss over operating wavelength range (not including TDL or connector losses).
2. In 2x2 couplers with a coupling ratio of 20% or lower, insertion loss is not specified for launch through second input port (P4).
3. Change in insertion loss from -5 to 75 °C.
Housing Option
Housing Code Description 1x2, 2x2 Dimensions (mm) Pigtail
2 Miniature 3.0 (Ø) x 45 (L) Primary-coated fiber
3 Regular 3.0 (Ø) x 50 (L) Primary-coated fiber
4 Ø 0.9 mm slim 3.0 (Ø) x 60 (L) Ø 0.9 mm loose-tube
5 Ø 0.9 mm semi-ruggedized 5.0 (Ø) x 75 (L) Ø 0.9 mm loose-tube
6 Ø 3.0 mm fully ruggedized 80 (L) x 10 (W) x 8 (H) Ø 3.0 mm fan-out sleeving