www.elektron-bulgin.com
For Polysnap modules BZV03,
BZV04, BZV09, BZV10,
BZV17, BZV18, BZH09,
BZH10, BZH17, BZH18,
BZM27, BZM28
PX0575 style IEC inlet
Using PS01/A style filter
Standard Attenuation Filter
Bxxxx/A xx x x / xx
Additional
Polysnap Part No. Filter Type Rating L/C Circuit Components Polysnap Part No.
From Polysnap Selection A = Standard 01 = 1A 1 = Version 1 0 = None From Polysnap Selection
03 = 3A 2 = Version 2 1 = Bleed (R) Resistor
06 = 6A 3 = Version 3 2 = Surge (VDR) Protection
10 = 10A 3 = “R” plus “VDR”
Rating Version L1 Cx Cy
1 AMP 1 2 x 2.8mH 1 x 15nF 2 x 2.2nF
“22 x 10mH 1 x 15nF 2 x 2.2nF
“32 x 10mH 1 x 47nF 2 x 2.2nF
3 AMP 1 2 x 0.75mH 1 x 15nF 2 x 2.2nF
“22 x 1.8mH 1 x 15nF 2 x 2.2nF
“32 x 1.8mH 1 x 47nF 2 x 2.2nF
6 AMP 1 2 x 0.3mH 1 x 15nF 2 x 2.2nF
“22 x 0.7mH 1 x 15nF 2 x 2.2nF
“32 x 0.7mH 1 x 47nF 2 x 2.2nF
10 AMP 1 2 x 0.17mH 1 x 15nF 2 x 2.2nF
“22 x 0.35mH 1 x 15nF 2 x 2.2nF
“32 x 0.17mH 1 x 47nF 2 x 2.2nF
Filter Specification
Max. Working Voltage: 250V a.c. 50-400Hz
Earth Leakage Current: <0.35mA (250V. 50Hz)
Temperature Range: –25ºC to +85ºC
Max. Ambient Temp.: 40ºC (derate linearly to 0A @ 85ºC)
(@ Full Load)
Test Voltage: 2700V d.c. 2 secs. Lines to Earth
1100V d.c. 2 secs. Live to Neutral
Approvals:
Attenuation Curves: See PS01/A filter, page 132
Part No. Example
BZV03/A0120/02 =
BZV style Polysnap module with PX0575 IEC
power inlet, filter rated at 1 amp, L/C circuit
version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF,
Cy = 2 x 2.2nF), without bleed resistor or surge
protection device fitted, 6.3mm tabs and single
pole red neon switch.
C14 IEC Inlet - Standard Filter
EMI FILTER OPTIONS
POLYSNAP®POWER INLET MODULES
125
IEC CONNECTORS
IEC CONNECTORS
Conns1 - Polysnap 2010:Conns1 - Polysnap 2005 8/6/10 16:54 Page 125