TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A PMT Highlights & Features * * * * Universal AC input range Power will not de-rate from input voltage 100Vac to 264Vac High MTBF > 700,000 hrs. per Telcordia SR-332 Short Circuit / Overvoltage / Overload / Over Temperature Protections Versatile connector options (Terminal Block, Front Face) * Safety Standards CB Certified for worldwide use Model Number: PMT-5V50W1A Unit Weight: 0.23 kg (0.51 lb) Dimensions (L x W x D): 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch) General Description The new PMT series of panel mount power supplies is the latest offering from one of the world's largest power supply manufacturers and solution providers - Delta. The PMT products also offer a nominal output voltage of 5V with a wide operating temperature range from -10C to +70C and can withstand shock and vibration requirements (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta's PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and this versatile product has three different connector options (Terminal Block and Front Face) and can also be converted into L Frame (PML) type of power supplies to satisfy different application needs. Model Information PMT Panel Mount Power Supply Model Number Input Voltage Range Output Voltage Output Current PMT-5V50W1A 85-264Vac 5Vdc 10.0A Model Numbering PM - 5V 50W 1 A Panel Mount Product Type T - Enclosed L - L Frame* Output Voltage Output Power Single Phase No PFC Connector Type A - Terminal Block G - Front Face* *Options **For Terminal Block 1 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current < 1.10A @ 115Vac, < 0.65A @ 230Vac Efficiency at 100% Load 82.0% typ. @ 230Vac Max Inrush Current (Cold Start) 45A typ. @ 230Vac Leakage Current < 1mA @ 240Vac Output Ratings / Characteristics Nominal Output Voltage 5Vdc Output Voltage Tolerance 1% (initial set point tolerance from factory) Output Voltage Adjustment Range 4.50-5.50Vdc Output Current 10.0A Output Power 50W Line Regulation < 0.5% typ. (@ 115Vac & 230Vac input, 100% input) Load Regulation < 1% typ. (@ 115Vac & 230Vac input, 0-100% input) PARD (20MHz) < 80mVpp @ 25C to 50C, < 160mVpp @ -10C to 0C Rise Time < 30ms @ nominal input (100% load) Start-up Time 1,200ms typ. @ 115Vac, 500ms typ. @ 230Vac (100% load) Hold-up Time 20ms typ. @ 115Vac, 100ms typ. @ 230Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) 10% (1000mVp-p) @ 0-100% load (Slew Rate: 0.1A/S) Start-up with Capacitive Loads 8,000F Max Mechanical Case Chassis Aluminium Case Cover SGCC Dimensions (L x W x D) 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch) Unit Weight 0.23 kg (0.51 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal Wire Noise (1 Meter from power supply) 2 PM-5V50W1AA M3.5 x 5 Pins (Rated 300V/15A) PM-5V50W1AG M3.5 x 5 Pins (Rated 300V/20A) PM-5V50W1AA AWG 14-12 PM-5V50W1AG AWG 14-12 Sound Pressure Level (SPL) < 25dBA All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Environment Surrounding Air Temperature Operating -10C to +70C Storage -25C to +85C Power De-rating Operating Humidity > 50C de-rate power by 2.5% / C < 100Vac de-rate power by 1.33% / V (80% load @ 85Vac) 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft) Shock Test (Non-Operating) IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions Vibration (Non-Operating) IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage 5.75-7.50V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent 105-150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature Non-Latching (Auto-Recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection *PE: Primary Earth Reliability Data MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 35C) Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40C) Safety Standards / Directives Electrical Safety TUV Bauart to EN60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation 3 Input to Output 3.0KVac Input to Ground 1.5KVac Output to Ground 0.5KVac All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A EMC EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A 2) Common Mode : 2kV 3) Differential Mode : 1kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 10A/Meter 1) Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 200A Criteria A1) 2) Common Mode : 2kV 3) Differential Mode : 1kV 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) Block Diagram 4 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Device Descriptions PMT-5V50W1AA: Terminal Block 1) 2) 3) PMT-5V50W1AG: Front Face Input & Output terminal block connector DC voltage adjustment potentiometer DC OK control LED (Green) Dimensions PMT-5V50W1AA: Terminal Block L x W x D: 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch) 5 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A PMT-5V50W1AG: Front Face L x W x D: 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch) PML-5V50W1AA: Terminal Block L x W x D: 98 x 98 x 37.5 mm (3.86 x 3.86 x 1.48 inch) 6 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A PML-5V50W1AG: Front Face L x W x D: 98 x 98 x 37.5 mm (3.86 x 3.86 x 1.48 inch) 7 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Engineering Data De-rating Note 1. 2. 3. 4. Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50C de-rate power by 2.5% / C 5. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature >50C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. Output De-rating VS. Input Voltage 8 No output power de-rating for the input voltage from 100Vac to 264Vac All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Assembly & Installation Mounting holes for power supply (device). The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. This surface belongs to customer's end system or panel where the power supply is mounted. Connector Side Mounting (Vertical) Base Mounting (Vertical) Fig. 2 * Side Mounting (Horizontal) Recommended Mounting Orientations PM-5V50W1AA / PM-5V50W1AG: Use flexible cable (stranded or solid) of AWG No. 14-12. User should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275" or 7mm (Refer to Fig. 3). Safety Distance D1 = 4.0mm Min. Fig. 3 Assembly Reference Ensure the mounted device is kept at 4mm safety distance at all sides from other components and equipments. In addition, to ensure sufficient convection cooling, always maintain a distance of 20mm from ventilated surfaces while the device is in operation. 9 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Fig. 4 For PMT and PML Series (Refer to Fig. 4): Only use M3 screw 3mm through the base mounting holes. This is to keep a safe distance between the screw and internal components. Recommended mounting tightening torque: 4~7Kgf.cm. Mounting Screw Safety Instructions * * * * * * * * If user's mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information. L frame (PML) and Open frame (PMB) options are to be manufactured by Delta and not to be reconfigured by users from the standard enclosed configuration. The device is not recommended to be placed on low thermal conductive surface. For example, plastics. The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! Do not touch the terminals while power is being supplied. Risk of electric shock. Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause electric shock, safety hazard, fire and/or product failure. The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded surface. Warning (For Standard Terminal Block and Front Face Terminal Block products): When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. Accessories L-01: Latch P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. 10 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Functions Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remains within 10% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. 11 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01) TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A Overload & Overcurrent Protections Overvoltage Protection The power supply's Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 105% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into "Hiccup mode" (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. The power supply's overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under "Protections". Over Temperature Protection It is not recommended to prolong the duration of Io when it is <105% but >100%, since it may cause damage to the PSU. As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. Short Circuit Protection The power supply's output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in "Hiccup mode", as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for "Restriction of the use of certain hazardous substances in electrical and electronic equipment". This product conforms to this standard. 12 All parameters are specified at 25C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2016, Rev. 01)