1
Fuses SPT 5x20
https://www.schurter.com /PG01_2
Circuit Protection
Miniature Fuse, 5 x 20 mm, Time-Lag T, H, 250 VAC, UL: 115 V - 300 VDC
See below:
Approvals and Compliances
IEC 60127-2 · 250 VAC · 300 VDC · Time-Lag T
Description
- IEC Standard Fuse
- H = High Breaking Capacity (Ceramic Tube)
Applications
- Primary Protection in Equipment
- Power Supply Adapter for e.g. laptops
- SMPS (Switching Mode Power Supply) for TV's and DVD's
References
Pigtail Type SPT 5x20 Pigtail
Assembled Fuseholder OGN-SMD
Fuse Kit Fuse Kit SP 5x20 / SPT 5x20
Weblinks
pdf data sheet, html datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Detailed request for product
Technical Data
Rated Voltage 250 VAC, 300 VDC
Rated current 0.5 - 16 A
Breaking Capacity 500 A - 1500 A
Characteristic Time-Lag T
Admissible Ambient Air Temp. -55 °C to 125 °C
Climatic Category 55/125/21 acc. to IEC 60068-1
Material: Tube Ceramics
Material: Endcaps Nickel-Plated Copper Alloy
Unit Weight 1.16 g
Storage Conditions 0 °C to 60 °C, max. 70% r.h.
Product Marking , Rated current, Rated Voltage, Cha-
racteristic, Breaking Capacity, Certifica-
tion marks
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.
2
Fuses
SPT 5x20 https://www.schurter.com /PG01_2
Circuit Protection
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: SPT 5x20
Approval Logo Certificates Certification Body Description
VDE Approvals VDE VDE Certificate Number: 40035651
VDE Approvals VDE VDE Certificate Number: 40014395
UL Approvals UL UL File Number: E41599
CCC Approvals CCC CCC Certificate Number: 2020970207000118 & more
KTL Approvals KTL Korea Testing Laboratory
METI Approvals METI Japan Electrical Safety and Environment technology Laboratories
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to UL 248-14 Low voltage fuses - Part 14: Additional fuses
Designed according to CSA22.2 No. 248.14 Low-Voltage Fuses - Part 14: Supplemental Fuses
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 62368-1 IEC 62368-1 includes the basic requirements for safety of audio, video,
information technology and office equipment.
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Dimension [mm] 20 mm
5.1
ø 5.2
20
+0.1
-0.2
±0.5
±0.6
5.1±0.6
3
Fuses SPT 5x20
https://www.schurter.com /PG01_2
Circuit Protection
Pre-Arcing Time
Rated Current In 1.5 x In min. 2.1 x In max. 2.75 x In min. 2.75 x In max. 4.0 x In min. 4.0 x In max. 10.0 x In min. 10.0 x In max.
0.5 A - 0.8 A 60 min 30 min 250 ms 80 s 50 ms 5 s 5 ms 150 ms
1 A - 3.15 A 60 min 30 min 750 ms 80 s 95 ms 5 s 10 ms 150 ms
4 A - 6.3 A 60 min 30 min 750 ms 80 s 150 ms 5 s 10 ms 150 ms
8 A - 10 A 30 min 30 min 750 ms 80 s 150 ms 5 s 10 ms 150 ms
12.5 A - 16 A 30 min 30 min 750 ms 80 s 150 ms 5 s 20 ms 150 ms
Time-Current-Curves
Time in Seconds
0.001
0.01
0.1
1
10
100
1000
10000
100000
1
10
0.8 A
1 – 3.15 A
4 – 10 A
_
> 12.5 A
Multiple of Rated Current In
All Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Rated Vol-
tage [VDC]
Breaking
Capacity
Voltage
Drop 1.0 In
max. [mV]
Voltage
Drop 1.0 In
typ. [mV]
Power
Dissipation
1.5 In max.
Power Dis-
sipation 1.5
In typ. [mW]
Melting I²t
10.0 In typ.
[A²s]
Order Number
0.5 250 300 1) 850 360 1600 500 0.5 l l 0001.2501
0.63 250 300 1) 650 330 1600 500 1.55 l l 0001.2502
0.8 250 300 1) 500 260 1600 500 2.3 l l 0001.2503
1 250 300 1) 350 180 2500 500 1.1 l llll0001.2504
1.25 250 300 1) 300 150 2500 500 1.86 l llll0001.2505
1.6 250 300 1) 200 130 2500 500 4.35 l llll0001.2506
2 250 300 1) 190 120 2500 600 9.2 l llll0001.2507
2.5 250 300 1) 180 100 2500 600 11.7 l llll0001.2508
3.15 250 300 1) 140 100 4000 800 22 l llll0001.2509
4 250 150 2) 100 90 4000 900 62.4 l llll0001.2510
5 250 150 2) 100 90 4000 1200 97.5 l llll0001.2511
6.3 250 150 2) 100 70 4000 1200 171 l llll0001.2512
8 250 150 3) 100 70 4000 1300 268 lllll0001.2513
10 250 150 3) 100 70 4000 2100 400 llll 0001.2514
12.5 250 125 4) 100 70 4000 2500 563 lll 0001.2515
16 250 125 4) 100 70 4000 3000 1500 l l 0001.2516
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
4
Fuses
SPT 5x20 https://www.schurter.com /PG01_2
Circuit Protection
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Rated Vol-
tage [VDC]
Breaking
Capacity
Voltage
Drop 1.0 In
max. [mV]
Voltage
Drop 1.0 In
typ. [mV]
Power
Dissipation
1.5 In max.
Power Dis-
sipation 1.5
In typ. [mW]
Melting I²t
10.0 In typ.
[A²s]
Order Number
1) IEC: H = 1500 A @ 250 VAC, p.f. = 0.7 - 0.8
1) UL: 10 kA @ 125 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 250 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 300 VDC
2) IEC: H = 1500 A @ 250 VAC, p.f. = 0.7 - 0.8
2) UL: 10 kA @ 125 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 250 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 150 VDC
3) IEC: 1000 A @ 250 VAC
3) UL: 1000 A @ 250 VAC, 1500 A @ 150 VDC
4) IEC: 500 A @ 250 VAC
4) UL: 500 A @ 125 VAC, p.f. = 0.7 - 0.8 / 1000 A @ 125 VDC / 500 A @ 250 VAC / 1500 A @ 125 VDC
Packaging Unit xxxx.xxxx Small Box Pack (10 pcs.)
xxxx.xxxx.G Bulk 128 x 91 x 60 mm (1000 pcs.)
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
19.10.2020