cui.com
CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 2 of 7
INPUT
parameter conditions/description min typ max units
operating input voltage
3.3 Vdc model
5 Vdc model
6.5 Vdc model
9 Vdc model
12 Vdc model
15 Vdc model
4.75
6.5
9.0
12
16
20
24
24
24
24
24
24
28
32
32
32
32
32
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
OUTPUT
parameter conditions/description min typ max units
line regulation Vin = min ~ max, at full load ±0.2 ±0.4 %
load regulation measured from 10% load to full load ±0.4 ±0.6 %
voltage accuracy 100% load ±2 ±3 %
switching frequency 100% load, input voltage range 280 330 450 kHz
temperature coefcient ±0.02 %/°C
load capacitance 1,000 μF
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous, automatic recovery
thermal shutdown 150 °C
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
MTBF as per MIL-HDBK-217F, 25°C 2,000,000 hours
RoHS compliant 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve -40 85 °C
storage temperature -55 125 °C
case temperature 100 °C
storage humidity non-condensing 95 %
lead temperature 1.5 mm from case for 10 seconds 300 °C
For more information, please visit the product page.