www.murata-ps.com/support
DMS-EB2
Multi-Purpose Application Board
for DMS-20PC/LCD Meters
MPM_DMS-EB2.F02 Page 2 of 4
TECHNICAL NOTES
APPLICATIONS
1. LCD Backlighting: To backlight a DMS-20LCD meter, connect J1,
pin 3 (TEST/HOLD IN) to J1, pin 6 (GND). This allows for external
control, via a switch, of the backlight feature. The switch should
be rated for low voltage operation at 35mA.
2. 9V LCD Meters: DMS-20LCD-X-9 meters cannot be used in a
single-ended conguration, i.e., with (–) IN LO tied to GND. On
these models, both (–) IN LO and (+) IN HI have to be a minimum
of 1.5V above and 1.5V below J1 pins 6 and 5, respectively. To
operate from a 9V or 12V battery with (–) IN LO tied to GND, use
a 5V-powered meter (DMS-20LCD-X-5), install U1 (LM7805CT)
and open SG4.
3. Input Resistor Dividers: Always use 1%, or better, metal-lm
resistors for R1 and R2, and also make sure their power and volt-
age ratings are adequate for the given application.
4. Using U1 (LM7805CT): The input power range specied in the
Battery Operation section is rated conservatively assuming a
100mA LED meter or a 35mA backlit LCD meter. If a non-backlit
LCD model or the low-power LED model is used, the input volt-
As shipped, the DMS-EB2 is congured for single-ended operation.
This conguration is preferred for simple voltage measurements and will
generally cover most standard applications. Figure 1 indicates which
solder gaps are shipped closed from the factory.
Simply solder the board onto the meter (pin 1 to pin 1), connect
the power supply to J1, pin 5 (+V) and the power return to J1, pin 6
(GROUND).
1. Decimal Point Placement: Murata Power Solutions ships the
DMS-EB2 with all decimal point solder gaps (SG1, SG2 and
SG3) open. To enable a specic decimal point, close its respec-
tive solder gap with solder. When re-assigning decimal places
for subsequent applications, remember to unsolder previously
closed solder gaps.
Close SG1 for 1.999 (DP1)
Close SG2 for 19.99 (DP2)
Close SG3 for 199.9 (DP3)
2. Display Test (Not Available on LCD Models): Tie pin 4 (TEST/
HOLD OUT) to pin 3 (TEST/HOLD IN) to test the display of the
DMS-20PC. Do not leave the meter in the test mode for more
than 10 seconds. On LED meters with the HOLD option, tying
pins 3 and 4 together freezes the display reading.
3. Battery Operation: Open SG4 and install U1 (LM7805CT) with
its metal tab facing to the left as shown in Figure 3. Allowable
input power ranges (J1, pins 5 and 6) are as follows:
DMS-20PC-X-XS +7.5 to +12.6Vdc
DMS-20PC-X-XL +7.5 to +32Vdc
C2 (10µF/35V) can be added to reduce noise. Observe correct
polarity. Refer to Technical Note 4 for more information.
Figure 2. J1 Connector Pinout
Pin Function
1 (+) INPUT HI
2 (–) INPUT LO
3 TEST/HOLD IN
4 TEST/HOLD OUT
5 +V (Positive power connection)
6 –V (Ground, negative power return)
DMS-EB2-C Application board with mating connector and terminals
DMS-BZL3-C DMS-20 bezel assembly
DMS-BZL4-C DMS-20 bezel assembly with sealing gasket
4320-01074-0 6-position pc-board socket
Input Supply Range
See applicable meter's data sheet
Input Supply Range U1 (LM7805CT) Installed:
DMS-20PC-X-XS +7.5 to +12.6V
DMS-20PC-X-XL +7.5 to +32.0V
DMS-20LCD-X-5 +7.5 to +32.0V
DMS-20LCD-X-5B +7.5 to +12.6V
Operating and Storage Temperature
See applicable meter's data sheet
Humidity 0 to 95%, non-condensing
Dimensions 1.25" (31.8mm)L x 0.75" (19.1mm)H
J1 Connector & Wire Information
Terminal Type MPS P/N 39-2099090
Crimp Tool MPS P/N 39-2099000
Wire Size 22 to 26 AWG
Insulation Diameter 0.062" (1.57mm) max.
Stripping Length 0.100" to 0.125"
(2.54 to 3.17mm)
Ordering Information
Functional Specications (TA = 25°C) age range can be extended up to 32Vdc.
A 10µF/35V tantalum capacitor (C2 on schematic) should be installed
with the polarized end next to the + symbol on the DMS-EB2. This is
especially important if the power source is located far from U1.
5. Soldering: Murata Power Solutions recommends the use of "no- clean"
See www.murata-ps.com/dpm-availability for model-specific
availability.