general data
scanning range sd 400 ... 2500 mm
scanning range close limit Sdc 400 ... 2500 mm
scanning range far limit Sde 400 ... 2500 mm
repeat accuracy < 1 mm
resolution < 0,3 mm
sonic frequency 120 kHz
response time ton < 160 ms
release time toff < 160 ms
temperature drift < 2 % of distance to target So
adjustment Teach-in
alignment aid target indication flashing
light indicator yellow LED / red LED
electrical data
voltage supply range +Vs 15 ... 30 VDC
output current < 20 mA
residual ripple < 10 % Vs
short circuit protection yes
reverse polarity protection yes
voltage output
current consumption max. (no load) 35 mA
output signal 0 ... 10 V / 10 ... 0 V
current output
current consumption max. (no load) 55 mA
output signal 4 ... 20 mA / 20 ... 4 mA
load resistance +Vs max. < 1100 Ohm
load resistance +Vs min. < 400 Ohm
mechanical data
type cylindrical threaded
housing material brass nickel plated
width / diameter 30 mm
height / length 95 mm
ambient conditions
operating temperature -10 ... +60 °C
protection class IP 67
sample picture
sample drawing
SW 36
LED
44,5ø
14,2
58,5
70
95
M30 x 1,5
M12 x 1
Teach-in
11
Teach-in = Teach-in or potentiometer
4/10/2013
UNAM 50
2
Ultrasonic distance measuring
sensors
Ultrasonic sensors
www.baumer.com
order reference output circuit connection types
UNAM 50I6121 current output cable, 2 m
UNAM 50I6121/S14 current output connector M12
UNAM 50U6121 voltage output cable, 2 m
UNAM 50U6121/S14 voltage output connector M12