LinkCharge CT
User and Installation Guide
www.semtech.com
WIRELESS CHARGING PRODUCTS
User and
Installation Guide
LinkCharge CT
Infrastructure Wireless
Charging System
SKU: DMTX-19V15W-EZ-SYS
Wireless Charging www.semtech.com 1 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
Objectives
This document serves as both a data sheet and an installation guide for the DMTX-19V15W-EZ-SYS wireless charging transmitter.
The first two sections provide an overview of the device and an introduction to the underlying Wireless Power standards and
concepts. The main body of this text presents a number of factors that help determine a proper location for the charger, and the
details of how to properly install the charger beneath a countertop. Following this are the detailed mechanical dimensions of the
device and the specifications the device performs to. Answers to some frequently asked questions are provided at the end of the
document.
Configuration
When obtained in single unit kit form, the kit will include the charger as well as the power supply for the charger and the power
cords associated with the power supply. Bulk orders may be placed for the charger alone, in which case the installer will need to
obtain the power supply and cords separately. This document will address both cases, so the user should keep in mind the included
items per their order, and plan accordingly.
Table of Contents
1 - Device Overview ............................................................................................................................... 2
2 - Wireless Power Technology Overview ................................................................................................ 3
3 - Installation Considerations ................................................................................................................ 4
4 - Installation Instructions .................................................................................................................... 5
5 - Mechanical Dimensions .................................................................................................................... 8
6 - Specifications ................................................................................................................................... 9
7 - FAQs .............................................................................................................................................. 12
Wireless Charging www.semtech.com 2 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
1 - Device Overview
MINIMUM SPACING
DESCRIPTION
The Infrastructure Transmitter Module is a
complete, self-contained system. When paired
with a WPC Qi 1.2 compatible receiver above the
transmitter coil, the module implements a WPC 1.2
wireless charging system with power output up to
15W. When paired with a PMA SR1 compatible
receiver above the transmitter coil, the module
implements a PMA SR1 wireless charging system
also with power output up to 15W. The transmitter
will automatically adjust the charging power, based
on the requirements of the receiver.
The Infrastructure Transmitter Module contains a
custom controller for managing the Qi or PMA
protocol and charging functions. The firmware in
the non-volatile memory of the microcontroller can
be modified to add user-defined functionality for a
specific customer application, and for some
models, allows upgradeability as standards change
and mature.
APPLICATIONS
Qi, PMA and non-standard wireless chargers
for countertop and furniture installations in:
oRestaurants and Hospitality sites
oTransportation hubs
oIndustrial applications
oEducational facilities
oHospitals
oPublic Enterprises
FEATURES
Supports Qi, PMA and proprietary charging
applications
Power output up to 15W
Easily mounts under counter or in most non-
metallic furniture surfaces
Determines correct wireless power protocol
depending on the receiver
Requires a 19V @ 2A DC input supply
Can be daisy-chained on a single power supply
for multi-site charging
LED indicators for power on, charging and
error conditions
SPECIFICATIONS
WPC Qi 1.2 compatible
PMA SR1 compatible
Compatible with fast charging phones
15W power output
Charges portable devices through up to
10 mm of material thickness
Wireless Charging www.semtech.com 3 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
2 - Wireless Power Technology Overview
WPC Qi Operation
When a WPC Qi compatible receiver is placed on the transmitter coil, the Infrastructure Transmitter Module implements a WPC Qi
1.2.1 wireless charging system at up to 15W output. The module will automatically adjust the charging power based on
instructions from the receiver. The transmitter LED will illuminate green for ~2 seconds, and then start flashing green; this
indicates charging is taking place. If the receiver coil moves too far in relation to the transmitter coil, the LED may illuminate solid
red, indicating an error condition. If this (or any other error condition) occurs, remove the receiver from the transmitter, wait for
the LED to turn off, and then replace the receiver on the transmitter.
The Infrastructure Transmitter Module contains an algorithm for sensing the presence of additional metal objects placed on the
transmitter (foreign object detection). When a metal object is placed on or near the transmitter coil before or during operation,
and if the metal object absorbs too much energy from the system, the transmitter will stop transmitting output power and the
Error LED will flash red.
PMA Operation
When a PMA compatible receiver is placed above the transmitter coil, the Infrastructure Transmitter Module implements a PMA
SR1 wireless charging system at up to 15W output. The module will automatically adjust the charging power based on instructions
from the receiver. The transmitter LED will illuminate green for ~2 seconds, and then start flashing green; this indicates charging
is taking place. If the receiver coil moves too far in relation to the transmitter coil, the LED may illuminate solid red, indicating an
error condition. If this (or any other error condition) occurs, remove the receiver from the transmitter, wait for the LED to turn off,
and then replace the receiver on the transmitter.
Wireless Charging www.semtech.com 4 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
3 - Installation Considerations
The DMTX-19V15W-EZ-SYS kit contains a wireless charging transmitter, along with the cords and transformer that powers it.
Below are instructions for how properly to locate and install this device.
Environmental Considerations
Select a location convenient and accessible for charging. Avoid locating the device where either the transmitter or receiver could
get wet, overly hot, or otherwise damaged. Don't locate the transmitter close to the edge of the counter to avoid the risk of the
wireless device (smartphone, etc) being accidentally knocked off the countertop and falling to the floor. Select a location with
some air flow to allow heat from the operating transmitter to dissipate. If the transmitter is to be replaceable, it should be
accessible to facilitate removal and replacement.
Electromagnetic Considerations
Locate the charger at least 1(25 mm) from any support structure. Assure that no metal is present above the transmitter unit.
Provide at least 1.5” (36 mm) of clearance above the charger, and 1” (25 mm) below the unit. If multiple chargers are present, allow
at least 6” (150 mm) spacing between each.
Identifying the Location of the Charging Point
Since efficient power transfer relies upon close coupling of the receiver with the transmitter, it is important that the user be able to
accurately locate their handheld device directly above the transmitter for charging. As such, consideration should be given to
providing some form of location guide on the counter top. The prominence and styling of these visual guides is a matter of
installer preference, and should take into consideration the needs of the end user. In a setting where the installation will be well
known to a limited number of users, a subtle or even temporary location guide may be sufficient. In settings where users won't be
familiar with the location of the charging site, a more prominent marking would likely be preferred, both to identify the availability
of the site and the optimal placement for the handheld device to be charged.
Mechanical Details
The charger should be mounted to the underside of a counter top. The installer should verify that the power and micro USB ports
are accessible after installation, and should plan for the routing of the DC power supply cable. The installer should also plan for the
mounting of the included power transformer. Lastly, the installer should plan for the routing of the AC cable from the transformer
to an available AC outlet.
Testing the Charger
Before installing the transmitter, verify its functionality:
1. Apply power and check to see that the green LED blinks once.
2. Place a 6 to 10 mm spacer above the charger coils:
- spacer can be made of any non-metallic material desired, e.g.: plastic, wood, cardboard, etc.
- Note: never place a receiver in direct contact with the
transmitter coil. The minimum allowable spacing is
6mm. Placement closer than this could damage the
receiving device and must be avoided at all times. Once
installed, this concern is eliminated, but the installer
must take this concern into account when testing the
device prior to installation.
3. Place a compatible handheld device over the spacer and verify that the device indicates charging has commenced.
Wireless Charging www.semtech.com 5 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
4 - Installation Instructions
As noted previously, the transmitter coil must be located between 6 and 8 mm below the top of the counter to provide the correct
transmitter to receiver spacing. In most cases, this will require milling a cavity into the underside of the counter into which the
charger can be mounted to achieve the correct spacing. The critical depth of cut will be the mounting point for the flanges of the
charger, as these will determine the spacing between the transmitter coil and the countertop.
As per the diagram to the left, a circle 110 mm or greater is required for the
body of the charger. If the location allows, a circle of 135 mm is
recommended, as this will allow easy access to the power and USB ports
after the device is installed. In the center of this cutout a further recess
should be created to accommodate the coils of the transmitter. This second
cut should be a minimum of
56 mm in diameter. A slightly larger diameter of perhaps 60 mm is
recommended to reduce the possibility of interference between the charger
and the countertop materials. It is also possible to create a cavity that
precisely matches the dimensions of the charger, but in most cases, the
simpler circular cutouts will do just as well and should be easier to produce
and require less sophisticated tools to achieve.
As per the diagram below, the flange cutout should be made to yield a
thickness of the countertop material of 13 mm with a tolerance of +/- 1 mm.
This is the critical measurement that defines the transmitter to receiver
spacing, so extra care in obtaining this distance should be exercised. The coil cutout must be at least another 6mm in depth
beyond the flange cutout, but the installer may prefer a slightly deeper cut of 7 mm or so to reduce the possibility of interference
between the charger and the countertop materials.
After the pocket is milled out, test-fit the charger and verify that there will be clearance for the power and USB connections. At-
tach the charger to the underside of the counter with two screws. Screws should be selected for the 2.9 mm diameter mounting
holes in the body of the charger, and should be of a length sufficient to pass through the 2 mm flange depth on the charger and
provide secure grip into the countertop material while not exceeding the 12-14 mm thickness of the countertop in this location.
Silicone adhesive may also be used to attach the charger, but in most cases is an inferior solution to the use of the recommended
mounting screws. Screws allow for easier removal of the device if required, and are more reliable than adhesive, which could
weaken over time and allow the device to detach and fall. Use of silicone adhesive requires extra care to apply the material only
onto the flange body to avoid getting any on the coil apparatus itself, which is not intended to be a mounting structure.
Wireless Charging www.semtech.com 6 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
Wiring
The transmitter kit includes a power supply compatible with the charger. If a volume purchase did not include the supply, one
must be obtained that meets the following specifications: 19 +/-1.5 V DC input supply, 1.32 A (or greater) with a plug at the end of
the DC line per the diagram below:
When planning the mounting the transmitter, attention should also be given to how the power cord(s) will be routed. While the
cord could simply be plugged into the charger and allowed to drape to the floor, embedding the cord within the counter or
attaching it to the underside of the counter should allow for greatly improved ergonomics, reliability, and aesthetics. It may be
optimal to cut a shallow channel into the underside of the counter to route the cabling through, so as to minimize the chance of
the cord interfering with anything below the counter. This is not a consideration unique to this charger, so the installer should
determine the cable routing as they would any other similar power cable.
LED Indicator
The LED present on the side of the transmitter indicates the state of the device. During device test, it can easily be observed, but
when mounted beneath a countertop it is not normally visible. If desired, the installer could use a length of fiber optic cable to
route the light from the LED to a location visible after installation. Normally, the device being charged will display the charging
status, so the need for status provided by the transmitter LED may be redundant. Below is a table defining the various LED
displays:
No Light
Charger Off or Standby
One Green Flash
Power Applied, Device Initialized
Continuous Flashing Green Light
Charging Cycle Underway
Steady Green Light
Charge Complete
Flashing Red Light
Foreign Object in Charging Field Remove Object, Restart Charging
Steady Red Light
Error Remove and Replace Receiver
Wireless Charging www.semtech.com 7 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
Firmware Update Procedure
Should a new firmware be developed for this device, it will be made available at www.semtech.com. A search for DMTX-19V15W-
EZ-SYS will lead to the support page for the device where any available firmware updates can be found.
Download the firmware file to a local folder on your computer. Also download the Semtech Wireless Power GUI, found by search-
ing on TS80000 and clicking on the Docs and Resources tab.
Install the GUI utility on your PC to be able to flash the firmware to the DMTX-19V15W-EZ-SYS unit.
To start the FW update process please follow the next steps in this exact order:
1. Make sure the 19V supply is disconnected from the DMTX-19V15W-EZ-SYS unit.
2. Run the GUI and select TS80000 from the "Device" menu.
3. Connect the USB cable to the computer and to the DMTX-19V15W-EZ-SYS unit.
4. Apply the 19V power to the DMTX-19V15W-EZ-SYS unit. At this point the GUI should detect the DMTX-19V15W-EZ-SYS unit.
Windows may try to automatically install a driver for the device. Make sure GUI Status shows "Connected". If not, please repeat
the whole process from step 1.
5. Click the "Firmware" tab, browse the firmware you want to program and then click the "Program" button. The GUI will indicate
the progress of the downloaded followed by the pop-up window confirming the successful firmware download.
6. Disconnect the USB cable and the 19V power supply
7. Reconnect the 19V power supply (and do not reconnect the USB cable). The DMTX-19V15W-EZ-SYS unit will power up with the
new firmware.
Wireless Charging www.semtech.com 8 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
5 - Mechanical Dimensions
Wireless Charging www.semtech.com 9 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
6 - Specifications
Mechanical Specifications
- Length 91.26 mm
- Width 82 mm
- Spacer Thickness of material
- Coil Type Custom
Electrical Specifications
- DC Input 19 +/-1.5 V DC input supply, 1.32 A (min)
- USB Port Firmware Update Input
- LED Indicates: off or standby (no LED), powerup (single green flash),
charging (green flashing), end-of-charge (green solid), foreign object detect (red flashing), or
error condition (red solid) per Qi specification
Temperature
- Operating ambient / Normal mode ambient: +0°C min / +30°C max
- Non-operating ambient: -40°C to +70°C (maximum rate of change of 20°C/hour)
Humidity
- Operating: to 85% relative humidity (non-condensing)
- Non-Operating: to 95% relative humidity (non-condensing)
Altitude
- Operating: to 5,000 ft.
- Non-operating: to 50,000 ft.
Mechanical Shock
- Non-operating: 50 G trapezoidal wave, velocity change = 170 in/sec
- Three drops in each of six directions are applied to each of the samples
Random Vibration
Non-operating
Sine sweep: 5Hz to 500Hz @ 0.5gRMS at 0.5 octave/min; dwell 15 min at each of 3 resonant points
Random profile: 5Hz @ 0.01g²/Hz to 20Hz @ 0.02g²/Hz (slope up); 20Hz to 500Hz @ 0.02g²/Hz (flat); Input
acceleration = 3.13gRMS; 10 min. per axis for 3 axis on all samples
Thermal Shock (Shipping)
Non-operating: -40°C to +70°C, 50 cycles, 30
C/min
transition time
15
C/min; duration of exposure to temperature
extremes for each half cycle shall be 30 minutes
Wireless Charging www.semtech.com 10 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
Safety Agency Test Results
As outlined in the following sections, Product Regulatory Requirements, the manufacturer will provide complete
copies of all safety agency reports and data submitted to the safety agencies. A copy of any additional data gathered
but not included in the data submitted to the safety agencies shall also be provided.
These tests shall be completed at all full rated load conditions, with the DC voltage margined, per typical safety
agency test requirements (i.e. -10% and +6%). The system is operated at maximum ambient temperature during this
series of tests.
Reliability / Warranty / Service
Component De-rating
The following component de-rating guidelines shall be followed. Any exceptions are subject to final approval.
Semiconductor junction temperatures shall not exceed 110
C
Transformer temperature shall not exceed 110
C
Inductor case temperature shall not exceed 85% of rated temperature in
C
Capacitor case temperature shall not exceed 85% of rated temperature in
C
Resistor wattage de-rating shall be > 30%
Component voltage and current de-rating shall be > 15%. During abnormal conditions (such as a short circuit)
no de-rating is required as long as the max rating is not exceeded.
Component Life requirement
All components life expectancy requirement is min 3 years, calculated at 75% of max continuous load @ 40
C ambient
temperature and @ 19V DC voltage.
Investigative Life Requirement
The system shall support a 5 year calculated life with a 90% confidence under the following conditions:
o 100 - 240VAC input
o 50
C ambient temperature
o 50% of the time at 20% load; 50% of the time at 80% load
Mean Time between Failures (MTBF)
The system shall have a minimum MTBF at continuous operation of
1. 100,000 hours at 75% load and 40C, as calculated by Bell core RPP, or
2. 250,000 hours demonstrated at 75% load and 40
C
Warranty Period
Two (2) years EU, one (1) year rest of the world.
Serviceability
No troubleshooting by maintenance personnel is to be performed. Only unit replacement will be done in the field.
Wireless Charging www.semtech.com 11 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
Modifications / Change Control
Following the qualification of the system, any changes in parts, materials, or processes used in system manufacturer
which affect form, fit, function, safety, reliability (Type One changes), or documentation of the power device (Type
Two changes) must be approved by customer prior to the incorporation of such changes.
Product Regulatory Requirements
Intended Application: This product is intended for indoor use only.
Product Safety
IEC60950-1 (International)
Product EMC Compliance Class B Compliance
Note: The product is required to comply with Class B emission requirements as the end system that it is configured
into is intended for a commercial environment and market place. System is to have
minimum of 3db margin to Class B Limits.
FCC /ICES-003 - Emissions (USA/Canada) Verification
CISPR 22 Emissions (International)
EN55022 - Emissions (Europe)
EN55024 - Immunity (Europe)
EN61000-4-2 Electrostatic Discharge
EN61000-4-3 Radiated RFI Immunity
EN61000-4-4 Electrical Fast Transients
EN61000-4-5 Electrical Surge
EN61000-4-6 RF Conducted
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interruptions
*EN61000-3-2 - Harmonics (Europe)
*EN61000-3-3 - Voltage Flicker (Europe)
CE EMC Directive 89/336/EEC (Europe)
*Refer to detailed Harmonic Requirements and Table 1
Certifications / Registrations / Declarations
UL Certification (US/Canada)
CE Declaration of Conformity (CENELEC Europe)
FCC/ICES-003 Class C Attestation (USA/Canada)
Wireless Charging www.semtech.com 12 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016
7 - FAQs
Q: Can the transmitter be tested by placing a compatible phone on top of the device?
A: No. A minimum spacing of 6 mm is required between the transmitter (charger) and receiver (phone, etc.). Placing a phone
directly on top of the receiver can damage the phone and must not be attempted. Once mounted 6 to 8 mm below a countertop,
this requirement will be met, and will be of no further concern. The only time extra care must be exercised is when the transmitter
is not installed beneath a counter. At these times, if the transmitter is to be used or tested, the operator must assure than a
nonmetallic 6 to 8 mm spacer is applied between the transmitter and receiver.
Q: Does this product include the power supply and power cords?
A: The DMTX-19V15W-EZ-SYS kit does include these items; however, future offerings of this device may include a non-kit ‘device
only’ version. The installer will need to provide their own power source when purchasing this version.
Q: Can I attach the transmitter to the counter with silicone adhesive rather than using screws?
A: Silicone adhesive is an option, but in most cases is an inferior solution to the use of the recommended mounting screws. Screws
allow for easier removal of the device if required, and are more reliable than adhesive, which could weaken over time and allow the
device to detach and fall. Use of silicone adhesive requires extra care to apply the material only onto the flange body to avoid
getting any on the coil apparatus itself, which is not designed to be a mounting structure.
Q: What is the recommended thickness of the countertop?
A: The countertop can be any thickness desired, as long as the critical 6-8 mm coil to countertop spacing is provided. Note that a
charger embedded in a 1” (25 mm) countertop will be nearly flush with the bottom of the countertop surface once installed, which
may be an attractive consideration.
Q: Do all the transmitters include the USB port?
A: All later production runs of the DMTX-19V15W-EZ-SYS include a USB port. The gray-colored first run of about 100 devices did
not. They are otherwise functionally identical to the later black-colored models, but cannot be easily updated with new firmware.
This may not be a concern in most cases, as the current firmware works well, and major updates are not anticipated. However, if
this is a concern, a simple inspection of the device will determine if the USB port is present or not.
Q: What if my questions weren’t answered here?
A: Go to the Semtech website at: http://semtech.com/wireless-charging. This is where all available information on Semtech’s
Wireless Charging products can be found. Your local Semtech FAE can also assist in answering your questions.
Wireless Charging www.semtech.com 13 of 13
Installation Guide Rev.2.3
DMTX-19V15W-EZ-SYS Dec. 2016