LT4H Timers DIN 48 SIZE DIGITAL TIMER Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market's needs. Features Pin type 1. Bright and Easy-to-Read Display A brand new bright 2-color back-lit LCD display. The screen is easy-to-read in any location, makes checking and setting procedures a cinch. 2. Simple Operation Seesaw buttons make setting and operation simple and easy. 3. Short Body of only 64.5 mm 2.54 inch (screw terminal type) or 70.1 mm 2.76 inch (pin type) With a short body, it is easy to install even in shallow control panels. 4. Conforms to IP66's Weather Resistant Standards The water-proof front panel keeps out water and dirt for reliable operation even in poor environments. Screw terminal type 5. Screw terminal and Pin Type are Both Standard The two terminal types are standard to support either through-panel installation or embedded installation. 6. Changeable Panel Cover A black panel cover is also available to meet your design requirements. 7. Conforms With EMC and Low Voltage Directives Conforms with EMC directives (EN50081-2/EN50082-2) and low-voltage directives (VDE0435/Part 2021) for CE certification vital for use in Europe. 8. EE-PROM Power Failure Memory EE-PROM memory retains setting and time data. Eliminates the need for battery replacement. Product types Time range 9.999 s (0.001 s~) 99.99 s (0.01 s~) 999.9 s (0.1 s~) 9999 s (1 s~) 99 m 59 s (1 s~) 999.9 min (0.1 m~) 99 h 59 min (1 m~) 999.9 h (0.1 h~) Operation mode Output Power ON delay (1) Power ON delay (2) Signal ON delay Signal OFF delay Pulse One-shot Pulse ON-delay Signal Flicker Totalizing ON-delay (8 modes) Operation voltage Power down insurance Terminal 100-240 V AC Relay (1 c) 12-24 V DC Available 100-240 V AC Transistor (1 a) 12-24 V DC Part No. 11 pin LT4H-AC240V Screw LT4H-AC240VS 11 pin LT4H-DC24V Screw LT4H-DC24VS 11 pin LT4HT-AC240V Screw LT4HT-AC240VS 11 pin LT4HT-DC24V Screw LT4HT-DC24VS Part names Time delay indicator TIMER LT4H DIP switches Elapsed time display 2 3 4 5 6 7 8 ON 1 Controlled output indicator Set time display Reset indicator OP. RST LOCK RESET Reset switch h m s Time units display Lock indicator UP Up keys LOCK Down keys Lock switch DOWN (Same for screw terminal type) 16 Specifications Item Operating voltage Frequency Power consumption Control capacity (resistive) Time range Time counting direction Rating Operation mode Signal, Reset, Stop input Lock input Input signal Time accuracy (max.) Contact Indication Power failure memory method Operating time fluctuation Temperature error Voltage error Setting error Power off time change error Contact arrangement Initial contact resistance Contact material Mechanical Life Electrical Operating voltage range Initial breakdown voltage Electrical Mechanical Operating conditions Initial insulation resistance (At 500 V DC) Operating voltage reset time Temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Air pressure Ripple rate Connection Protective construction Ralay output type Transistor output type AC type DC type AC type DC type 12 to 24 V DC 100 to 240 V AC 100 to 240 V AC 12 to 24 V DC -- 50/60 Hz common 50/60 Hz common -- Max. 3 W Max. 10 V A Max. 10 V A Max. 3 W 5 A, 250 V AC 100 mA, 30 V DC 9.999 s, 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 999.9 min, 99 h 59 min, 999.9 h (selected by DIP switch) Addition (UP)/Subtraction (DOWN) (2 directions selectable by DIP switch) A (Power ON delay), A2 (Power ON delay), B (Signal ON delay), C (Signal OFF delay), D (Pulse one-shot), E (Self-hold), F (Flicker), G (Totalizing) (Selectable by DIP switch) Min. input signal width: 1 ms, 20 ms (2 directions by selected by DIP switch) Min. input signal width: 20 ms Open collector input Input impedance: Max. 1 k; Residual voltage: Max. 2 V Open impedance: 100k or less, Max. energized voltage: 40V DC 7-segment LCD, Elapsed value (backlight red LED), Setting value (backlight yellow LED) EE-PROM (Min. 105 overwriting) (0.005 % + 50 ms) in case of power on start (0.005 % + 20 ms) in case of reset or input signal start (at fixed power off time) 100 ms Timed-out 1 Form C 100 m (at 1 A 6 V DC) Ag alloy/Au flash Timed-out 1 Form A (Open collector) -- -- 2.0 x 107 ope. (Except for switch operation parts) -- 1.0 x 10 ope. (At rated control voltage) 1.0 x 10 ope. (At rated control voltage) 5 7 85 to 110 % of rated operating voltage 2,000 Vrms for 1 min: Between live and dead metal parts 2,000 Vrms for 1 min: Between live and dead metal parts 2,000 Vrms for 1 min: Between input and output 2,000 Vrms for 1 min: Between input and output 1,000 Vrms for 1 min: Between contacts Between live and dead metal parts Min. 100 M: Between live and dead metal parts Min. 100 M: Between input and output Between input and output Between contacts Max. 0.5 s -- Max. 65 C (under the flow of nominal operating current at nominal voltage) 10 to 55 Hz: 1 cycle/min single amplitude of 0.35 mm .014 inch (10 min on 3 axes) 10 to 55 Hz: 1 cycle/min single amplitude of 0.75 mm .030 inch (1 h on 3 axes) Min. 98 m 321.522 ft./s2 (4 times on 3 axes) Min. 294 m 964.567 ft./s2 (5 times on 3 axes) -10 C to 55 C +14 F to +131 F Max. 85 % RH 860 to 1,060 h Pa 20 % or less -- 20 % or less 11-pin/screw terminal IP66 (front panel with rubber gasket) 17 Dimensions (units: mm inch) * LT4H digital timer Pin type (through-panel or surface mount installation) Screw-down terminal type (through-panel installation) 5.5 .217 48 1.890 TIMER 70.1 2.760 55.6 2.189 5.5 .217 64.5 2.539 LT 4 H OP. 48 1.890 (44.5 (1.752 s (44.5 (1.752 UP RESET LOCK DOWN 7.5 .295 7.5 .295 * Dimensions for through-panel installation (with adapter installed) Screw-down terminal type Pin type 48 1.890 LT4H OP RST LOCK h m 50 1.969 s UP RESET LOCK DOWN 1 .039 48 1.890 Installation panel Rubber gasket ATC18002 (supplied) Installation frame ATA4811 (supplied) TIMER (44.5 (1.752 66 2.598 LT4H OP RST LOCK 48 1.890 ,,,,,,,,,,,,, TIMER ,,,,,,,,,,, Installation panel Rubber gasket ATC18002 (supplied) h m 50 1.969 s UP RESET LOCK DOWN 1 .039 48 1.890 63.5 2.500 Installation frame ATA4811 (supplied) 66 2.598 90 3.543 11P cap ATA4861 (sold separately) * Dimensions for surface mount installations * Installation panel cut-out dimensions * For connected installations The standard panel cut-out dimensions are shown below. Use the installation frame (ATA4811) and rubber gasket (ATC18002). DIN rail terminal block ATC18004 (sold separately) 45-0.6 0 45-0.6 0 1.772-.024 0 80 min. 3.150 1.772-.024 0 A A = (48 x n - 2.5) -0.6 0 -.024 0 45 1.772 Device installation rail ATA48011 (sold separately) -0.6 0 Note 1: The installation panel thickness should be between 1 and 5 mm .039 and .197 inch. Note 2: For connected installations, the waterproofing ability between the unit and installation panel is lost. 80 min. 3.150 95.5 3.760 Terminal layout and wiring * Pin type Relay output type Reset Signal Stop Lock 5 6 7 4 3 2 (-) 18 1 11 Transistor output type NC NO 8 9 10 Operation voltage Reset Signal Stop Lock 2 COM (+) (-) Reset Signal Stop Lock 5 6 7 4 3 1 11 8 9 10 Operation voltage * Screw-down terminal type Relay output type (+) 6 7 8 9 10 1 2 3 4 5 (+) Operation voltage (-) COM NO NC Transistor output type Reset Signal Stop Lock 6 7 8 9 10 1 2 3 4 5 (+) Operation voltage (-) Setting the operation mode, timer range, and time Setting procedure 1) Setting the operation mode and timer range Set the operation mode and timer range with the DIP switches on the side of the unit. DIP switches Table 1: Setting the operation mode Note: Set the DIP switches before installing the unit. DIP switch Item OFF ON 1 Operation mode Refer to table 1 2 3 4 5 6 7 8 Minimum input reset, signal, and stop signal width 20 ms DIP switch No. 1 2 3 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON 1 ms Time delay direction Addition Subtraction Timer range Refer to table 2 Operation mode A: Power on delay A2: Power on delay B: Signal on delay C: Signal off delay D: Pulse One shot E: Pulse On delay F: Signal Flicker G: Totalizing On delay Table 2: Setting the timer range DIP switch No. 6 7 8 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON DIP switches 2 3 4 5 6 7 8 ON 1 (Same for screw-down terminal type) Timer range 0.001 s to 9.999 s 0.01 s to 99.99 s 0.1 s to 999.9 s 1 s to 9999 s 0 min 01 s to 99 min 59 s 0.1 min to 999.9 min 0 h 01 min to 99 h 59 min 0.1 h to 999.9 h Setting procedure 2) Setting the time Set the set time with the keys on the front of the unit. Front display section Q Elapsed time display W Set time display E Time delay indicator R Controlled output indicator T Reset indicator Y Lock indicator U Time units display 3 TIMER LT4H 4 5 2 OP RST LOCK 6 10 11 RESET h m s UP 7 8 LOCK 9 DOWN * Changing the set time 1. It is possible to change the set time with the up and down keys even during time delay with the timer. However, be aware of the following points. 1) If the set time is changed to less than the elapsed time with the time delay set to the addition direction, time delay will continue until the elapsed time reaches full scale, returns to zero, and then reaches the new set time. If the set time is changed to a time above the elapsed time, the time delay will continue until the elapsed time reaches the new set 1 time. 2) If the time delay is set to the subtraction direction, time delay will continue until "0" regardless of the new set time. 2. If the set time is changed to "0," the unit will operate differently depending on the operation mode. 1) If the operation mode is set to A (power on delay) or A2 (power on delay), the output will turn on when the power supply is turned on. However, the output I UP keys Changes the corresponding digit of the set time in the addition direction (upwards) O DOWN keys Changes the corresponding digit of the set time in the subtraction direction (downwards) P RESET switch Resets the elapsed time and the output { LOCK switch Locks the operation of all keys on the unit will be off while reset is being input. 2) In the other modes, the output turns on when the signal is input. When the operation mode is C (signal off delay), D (one shot), or F (flicker), only when the signal input is on does the output turn on. Also, when the reset is being input, the output is off. 19 T: Set time t1, t2, t3, tata+tb T t1+t2=T T>t ta tb t Operation type Pulse One-Shot D Pulse On delay E Signal Flicker F Totalizing On delay G Explanation * Set the operation mode 1 2 3 section of the DIP switches ON ON OFF (no.'s 1, 2, and 3) on the side of the timer as shown. * Clears elapsed time value at power ON. * Time delay starts and output control ON at signal ON. * Ignores signal input during time delay. * Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. * Set the operation mode 1 2 3 section of the DIP switches OFF OFF ON (no.'s 1, 2, and 3) on the side of the timer as shown. * Clears elapsed time value at power ON. * Time delay starts at signal ON. * Ignores signal input during time delay. * Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. * In order to have the time delay start at power ON or reset at power OFF, jumper the signal input beforehand. * Set the operation mode 1 2 3 section of the DIP switches ON OFF ON (no.'s 1, 2, and 3) on the side of the timer as shown. * Clears elapsed time value at power ON. * Time delay starts at signal ON. * Ignores signal input during time delay. * Output control reverses, elapsed time value clears, and timer delay starts at timer completion. * Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. * In order to have the time delay start at power ON or reset at power OFF, jumper the signal input beforehand. * Set the operation mode 1 2 3 section of the DIP switches OFF ON ON (no.'s 1, 2, and 3) on the side of the timer as shown. * Elapsed time value does not clear at power ON. (power outage countermeasure function) * The output remains ON even after the power is cut and restarted. * Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. Time chart Power supply ON OFF Output ON OFF Reset ON OFF Stop ON OFF Signal ON OFF Power supply ON OFF Output ON OFF Reset ON OFF Stop ON OFF Signal ON OFF Power supply ON OFF Output ON OFF Reset ON OFF Stop ON OFF Signal ON OFF Power supply ON OFF Output ON OFF Reset ON OFF Stop ON OFF Signal ON OFF T=t1+t2 T>ta T t1 T ta t2 t T=t1+t2 T t1 t2 T=t1+t2 T T t1 t2 ta t1 t2 T T=t1+t2 T>ta T T=t1+t2+t3 T T t1 t2 T>ta t3 ta 21 MOUNTING PARTS * Rubber gasket 50.0 1.969 50.0 1.969 ATC18002 ACCESSORIES * Panel cover (Black) ATL58011 22 1.0 .039