Product Data Sheet 3214 J/2H4PU
11/19/2014 page 5 of 11
3.2 Electrical Operating Data
Measurement
conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see section 3.5)
I: corresp. to arithm. mean current value
PWM 0001 PWM: 100 %; f: 1 kHz f: 5 kHz
Voltage range ∆p = 0 U 12,0 V 27,6 V
Nominal voltage ∆p = 0 U
24,0 V
Power consumption ∆p = 0
PWM 0001 P 12,0 W 50,0 W 50,0 W
Tolerance +- 17,5 % +- 17,5 % +- 25,0 %
Current consumption ∆p = 0
PWM 0001 I 1.000 mA 2.000 mA 1.800 mA
Tolerance +- 17,5 % +- 17,5 % +- 25,0 %
Speed ∆p = 0
PWM 0001 n 7.800 1/min 13.000 1/min 13.000 1/min
Tolerance +- 12,5 % +- 7,5 % +- 3,0 %
Starting current
consumption 6.500 mA
Inrush current 34.000 mA
PWM 0002 PWM: 50 %; f: 1 kHz f: 5 kHz
Voltage range ∆p = 0 U 12,0 V 27,6 V
Nominal voltage ∆p = 0 U
24,0 V
Power consumption ∆p = 0
PWM 0002 P 10,4 W 12,0 W 12,0 W
Tolerance +- 17,5 % +- 25,0 % +- 25,0 %
Current consumption ∆p = 0
PWM 0002 I 870 mA 500 mA 435 mA
Tolerance +- 17,5 % +- 25,0 % +- 25,0 %
Speed ∆p = 0
PWM 0002 n 7.350 1/min 7.500 1/min 7.500 1/min
Tolerance +- 12,5 % +- 5,0 % +- 5,0 %