L-Series Switch The L-Series rocker switch is an innovative product offering total design flexibility, while at the same time setting new standards for performance and reliability. Its versatile design features include a neatly proportioned size that fits into an industry standard mounting hole of 1.734 x .867 (44.0mm x 22.0mm), countless unique choices for ratings, circuits, colors, illuminations and laser etched legends. These single or double pole switches also feature a broad choice of actuator styles, colors, and lenses with up to twelve terminals offering an extensive range of switch and lamp circuit options, including LED or incandescent illumination. Additionally, an optional plug-in terminal connector enables pre-wiring of wire your harness. Typical Applications: Performance Features: IP67 certified sealed front panel components Construction machinery Withstands temperatures from -40C to +85C Agricultural equipment Vibration, shock, thermoshock, moisture and salt spray On-highway transportation equipment Carling Technologies, Inc. 60 Johnson Avenue * Plainville, CT 06062-1177 Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com resistant 2 | L-Series Sealed Rocker Switches L-Series Switch DESIGN FEATURES ELIMINATES NEED FOR RETOOLING Neatly proportioned, the L-Series fits into an industry standard mounting hole of 1.734 x .867 [44.0mm x 22.0mm]. INTEGRATES EASILY INTO YOUR SYSTEM Available with two industry standard termination options, .250 TAB or .187 TAB. ENSURES GREATER SHOCK PROTECTION Welded lamp connection and one-piece internal, jumperless terminal withstand extreme shock and vibration. WITHSTANDS EXTREME TEMPERATURES Roller pin mechanism eliminates need for lubricants, Withstanding temperatures from -40C to +85C. MAXIMIZES YOUR DESIGN FLEXIBILITY Twelve terminals offers an extensive range of switch and lamp circuit options, including LED or incandescent illumination. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com L-Series Sealed Rocker Switches - General Specifications | 3 Electrical Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC Dielectric Strength 1250 Volts RMS between pole to pole 3750 Volts RMS between live parts and accessible surfaces Insulation Resistance 50 Megaohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 100,000 cycles maintained, 50,000 cycles momentary at rated voltage and current Contacts 90/10 silver-nickel, silver tin-oxide, gold Terminals Brass or copper/silver plate 3/16" (4.76mm) & 1/4" (6.3mm) Quick Connect terminations standard. Mechanical Endurance 250,000 cycles minimum Physical Lighted Incandescent - rated 10,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24 VDC) Rocker, base & bracket are sealed. Nylon 66 GF rated to 85C with a flammability rating of 94V0. Nylon 66 Reinforced, rated to 105C (modular lens). Locking rocker, standard rocker & paddle. Laser etching with a polycarbonate actuator. Acetal Polycarbonate rated at 100C. Nylon Zytel Nylon 66 rated at 85C. Polarized. Seals Base Rocker Lock Lens Bracket Connector Actuator Travel (Angular Displacement) 2 position 3 positions 26 1.970 13 from center .390 [9.91] Environmental Environmental IP67 for above panel components of the actual switch, representing an index of protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. Corrosion Mixed Flowing Gas MFG Class III per ASTM B-827 & B-845, Method H, with 3 years exposure. Operating Temperature -40C to + 85C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G's 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 10 G's peak Results Horizontal Axis 3-5 G's max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10 chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G's. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55C to 85C. Test criteria - pre and post test contact resistance. Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance. Mounting Specifications .867 [22.02] 1.734 [44.04] .260 [6.60] 1.020 [25.91] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE .100 [2.54] 2.265 [57.53] 3.055 [77.60] *Manufacturer reserves the right to change product specification without prior notice. T1 BAT T2 OUTPUT (LOAD) Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 .250 X .031 [6.35 X .79] T3 GROUND PADDLE STYLE ACTUATOR 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 1.300 [33.02] Q.C. SELECTION GUIDE 4 | L-Series Sealed Rocker Switches - Dimensional Specifications in. [mm] Dimensional Specifications: in. [mm] L-SERIES L-SERIES SHOWN WITH LASER ETCHED ACTUATOR SHOWN WITH ROCKER GUARD 1.970 [50.04] 1.020 [25.91] .435 [10.16] .400 [10.16] 1.450 [36.83] .855 [21.72] L-SERIES L-SERIES SHOWN WITH LARGE LENS AND PADDLE ACTUATOR SHOWN WITH BAR LENS, LOCK AND CONNECTOR 1.970 [50.04] 1.020 [25.91] .453 [11.51] .400 [10.16] Connector LC1-01 LC2-01 LC3-01 12 4 3 2 1 10 12 4 3 2 1 10 Hole Plug L-SERIES CONNECTOR L-SERIES HOLE PLUG BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES) BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES) 1.970 [50.04] BLACK .250 TAB CONNECTOR (AMP ONLY) 2.380 [60.45] LH1 REMOVABLE HOLE PLUG WITH NON-SERRATED WINGS LH2 HOLE PLUG WITH SERRATED WINGS 1.020 [25.91] .500 [12.70] 1.325 [33.66] .920 [23.37] 1.710 [43.43] .790 [20.07] .300 [7.62] .855 [21.72] 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com L-Series Sealed Rocker Switches - Dimensional Specifications in. [mm] | 5 Dimensional Specifications: in. [mm] +.008 -.000 +.008 -.000 .984 [25.00] 2.020 [51.31] R .093 MAX TYP R .093 MAX TYP MOUNTING PANEL TEST CUT HOLE IN ACTUAL MATERIAL TEST CUT HOLE IN ACTUAL MATERIAL +.008 -.000 1.900 [48.26] LMS MOUNTING PANEL HOLE FOR ADDITIONAL UNITS, ADD 1.03 [26.2] PER UNIT. FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE SECTION. AVAILABLE IN PANEL THICKNESSES LISTED BELOW. CONSULT FACTORY +.008 -.000 1.900 [48.26] DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF CENTER BEZELS (LMM) X 1.034 [26.26mm] MOUNTING PANEL THICKNESS .062 [1.57] .093 [2.36] .125 [3.17] .156 [3.96] MOUNTING PANEL OPENING (2) UNITS 2.300 [58.42] 2.300 [58.42] 1.187 [30.15] 1.030 [26.16] LME MOUNTING PANEL END 1.990 [50.55] 2.300 [58.42] 1.340 [34.04] LMM MOUNTING PANEL MIDDLE LMS MOUNTING PANEL 1.700 [43.18] 1.030 [26.16] 1.030 [26.16] .670 [17.02] 2.300 [58.42] 2.300 [58.42] 3.400 [86.36] 4.430 [112.52] LM3 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 3.06 [48.3mm X 77.7mm] LM4 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 4.09 [48.3mm X 103.9mm] 1.030 [26.16] .670 [17.02] 2.300 [58.42] 6.490 [164.85] LM6 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 6.15 [48.3mm X 156.2mm] 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 6 | L-Series Switch - Circuit Diagrams CIRCUIT CODE CIRCUIT CODE SCHEMATIC CIRCUIT CODE SCHEMATIC 5 4 4 11 22 6 2 4 2 23 2 6 2 1 4 2 1 14 2 6 4 54 2 2 1 4 6 4 8 5 26 15 2 4 1 1 17 2 6 4 6 2 1 18 4 2 1 3 31 2 6 2 21 6 4 3 4 58 2 8 1 8 5 30 4 3 57 2 4 4 8 5 28 1 4 3 8 5 2 4 3 56 2 1 4 1 2 6 4 27 16 2 55 2 1 4 3 8 5 25 1 3 53 2 4 4 1 8 5 24 1 4 3 52 2 13 3 5 4 4 1 51 2 12 SCHEMATIC 4 5 7 2 8 1 3 5 7 2 4 6 8 61 2 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com L-Series Switch - Circuit Diagrams | 7 CIRCUIT CODE CIRCUIT CODE SCHEMATIC 3 SCHEMATIC 7 1 62 4 5 4 5 8 71 2 4 1 3 6 8 5 7 2 1 7 63 8 72 2 4 6 7 2 8 3 4 7 64 8 73 2 4 1 3 6 7 2 8 5 5 4 7 65 8 80 2 4 6 6 2 8 3 4 7 5 1 8 81 66 2 4 6 6 2 8 3 1 7 67 5 4 8 82 2 4 6 6 3 8 8 4 1 68 2 3 4 7 8 A2 INTERNAL CONNECTION 7 2 6 8 4 1 69 1 4 7 8 A3 INTERNAL CONNECTION 7 2 1 4 2 5 6 8 70 2 7 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 8 | L-Series Lamp - Circuit Diagrams ILLUMIN. CODE SCHEMATIC ILLUMIN. CODE -9 -9 A A 1 ILLUMIN. CODE SCHEMATIC SCHEMATIC ILLUMIN. CODE -9 J 1 1 B B C +10 +12 -9 +4 D 1 -9 +4 E 1 F 1 1 2 2 1 1 -12 INTERNAL CONNECTION INTERNAL CONNECTION 2 2 -12 K K (+)10 +4 INTERNAL CONNECTION INTERNAL CONNECTION 1 +10 +10 (-)9 (-)9 1 1 (+)10 SYMBOL +8 1 2 -9 SYMBOL DEFINITION TERMINAL LOCATION MAINTAINED CIRCUIT MAINTAINED CIRCUIT 2 MOMENTARY CIRCUIT MOMENTARY CIRCUIT INTERNAL CONNECTION (JUMPER TERMINAL) +4 2 POSITION CONNECTION G 1 2 2 P3 P1 P3 +10 -9 -9 H 1 +10 P3 H 1 2 2 P2 P1 P3 INTERNAL CONNECTION (JUMPER TERMINAL) 2 POSITION CONNECTION P1 2 POSITION 2 POSITION +10 DEFINITION TERMINAL LOCATION LAMP LOCATION LAMP LOCATION +10 +4 LEGEND LEGEND 2 -9 2 +10 +10 +12 +4 1 2 +8 +10 G 2 +10 -9 -9 1 2 -12 1 +10 F +4 -12 +12 1 2 +10 E 2 +12 -9 1 -9 1 2 -9 D J -11 -11 -9 +4 +1 +10 +10 C +1 SCHEMATIC -9 P2 P1 3 POSITION +10 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 3 POSITION L-Series Sealed Rocker Switches - Ordering Scheme | 9 L 11 E 3 C H N 1 -- 3 A A 45 -- 1 48 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES L Terminal Orientation ( ) - momentary SP - single pole - uses terminals 1, 2 & 4. DP - double pole uses terminals 5, 6 & 8. Terminals 9, 10 & 11 for lamp circuit only. 1 SP DP 2 & 3, 6 & 8 11 21 ON 12 22 (ON) 13 23 ON 14 24 ON 15 25 ON 16 26 ON 17 27 ON 18 28 (ON) CIRCUITS WITH JUMPER TERMINALS 30* (2,4 & 5), (1,6&8) 31 1, 2 & 5 PROGRESSIVE CIRCUITS 51 3&4 52 3&4 53 (3 & 4) 54 (3 & 4) 55 (3 & 4) 56 (3 & 4) 57 3&4 58* 2&4 61 3 & 4, 7 & 8 62 3 & 4, 7 & 8 63 (3 & 4) , ( 7 & 8) 64 (3 & 4) , ( 7 & 8) 65 (3 & 4) , ( 7 & 8) 66 (3 & 4) , ( 7 & 8) 67 3 & 4, 7 & 8 68 2 & 4, 7 & 8 69* 2 & 4, 1, 7 & 8 70 (2 & 4) , ( 7 & 8) 71 (2 & 4) , ( 7 & 8) 72 2 & 4, 7 & 8 73 (2 & 4) , ( 7 & 8) 80 2 & 4, 6 & 8 HAZARD WARNING CIRCUITS A2 6,7&8,3&4 A3 6,7&8,2&4 * Available with ratings 1, 4, & E only. 2 3 OFF, OFF 2, 3 & 7 (1,2 & 8), (4,5&6) 2, 4 & 8 2&3 2&3 2&3 2&3 2&3 2&3 2&3 2&3 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 4, OFF 2 & 4, OFF 2 & 4, 5 & 7 2 & 4, 5 & 7 2 & 4, 5 & 7 2 & 4, OFF 2 & 4, OFF 1&2 OFF 1&2 OFF (1 & 2) (OFF) (OFF) 1&2 1 & 2, 5 & 6 OFF, OFF 1 & 2, 5 & 6 OFF, OFF (1 & 2), (5 & 6) (OFF, OFF) (OFF, OFF) OFF, OFF OFF, OFF (1 & 2), (5 & 7) 1 & 2, 5 & 7 1 & 2, 5 & 7 OFF, OFF OFF, 5 & 6 NONE NONE OFF, 1 & 2 OFF, 1 & 2 Connected Terminals NONE NONE NONE NONE NONE OFF OFF OFF 1 & 2, 5 & 6 OFF OFF (OFF) ON (ON) ON (ON) (ON) 3 RATING2 1 4 B C D E G H .4VA @ 28VDC Resistive 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings 15A 24V 20A 18V 20A 12V 15A 12V 20A 6V 20A 3V 4 TERMINATION2,3,4 1 3 10 11 12 Lens Style Lens Style Legend & Color & Color 13 14 Legend Actuator Orientation Lens Legend 5 ILLUMINATION 2 CIRCUIT2 Position: 9 Actuator .250 (6.4mm) TAB (QC) .187 (4.7mm) TAB (QC) 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 10 & 9; Selection 7: above terminals 12 & 11 0 No lamp 7 18V 4 3V 5 6V 6 12V Incandescent Red Amber Green LED* A L F 2VDC B M G 6VDC C N H 12VDC D P J 24VDC * Consult factory for "daylight bright", blue/green and white LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR1 Black 1 A E Standard Bracket Rockerguard at Lamp 1 Rockerguard at Lamp 2 White 2 B F 9 ACTUATOR STYLE AND COLOR1 Black A J Rocker Paddle White B N Gray C K Gray 3 C G Red 4 D H Red D M Laser Etched 3 4 8 24V 10 & 11 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue 1 B G M T Large Transparent 7 C H N U Large Translucent 3 D J P V Bar Transparent 9 E K R W Bar Translucent 5 A - Laser Etch background color 12 LASER ETCH, LENS OR BODY LEGEND 00 No legend this location / no actuator For legend options & codes, see pages 54-65 of the Carling Transportation catalog. 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 - vertical, lamp 1 on top Orientation 2 - horizontal, lamp 1 on right Orientation 3 - vertical, lamp 1 on bottom Orientation 4 - vertical, lamp 1 on left Orientation 1 Orientation 2 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Circuits 30, 31, 58, 69 are not available with rating codes 4, C, D, G or H. 3 Termination 3 only available with rating codes 1, B, and E. 4 Termination 1 not available with rating code 4. 5 Not available with circuits 11-18, 51-57 and 69. Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only. Lamps Illumination Type Lamp wired to Terminals NONE S #1 Independent 10+ 9A B #2 Independent 12+ 11C #1 Independent 10+ 9 Independent 12+ 9#1 Dependent 4+ 9D E #1 Independent 10+ 9 Dependent 4+ 9F5 #1 Independent 10+ 9 Dependent 8+ 9#1 Dependent 4+ 9G  Independent 10+ 9#1 Both Independent 10+ 9H  (in series) #1 Dependent 4+ 9J  Dependent 1+ 91 #2 Hazard 6+ 1012#1 Hazard 6+ 10122 Orientation 4 1 Series AA 46 46 3AA-146 AA 3AA-246 14 ACTUATOR LENS LEGEND Orientation 3 00 No legend this location / no actuator For legend options & codes, see pages 54-65 of the Carling Transportation catalog. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 10 | L-Series Sealed Locking Rocker Switches - Ordering Scheme L 11 D 1 S W C J -- P M H 00 -- 0 2 Circuit 3 Rating 4 5 6 Termination Illumination Lock 7 Lamp 8 Bracket 1 SERIES L W ( ) - momentary SP - single pole - uses terminals 1, 2 & 4. DP - double pole uses terminals 5, 6 & 8. Terminals 9, 10 & 11 for lamp circuit only. Position: 1 SP DP 2 & 3, 6 & 8 11 21 ON 14 24 ON 16 26 ON 17 27 ON 18 28 (ON) CIRCUITS WITH JUMPER TERMINALS 302 (2 ,4 & 5), (1,6&8) 312 1, 2 & 5 PROGRESSIVE CIRCUITS 51 3&4 52 3&4 53 (3 & 4) 54 (3 & 4) 55 (3 & 4) 56 (3 & 4) 57 3&4 58 2&4 61 3 & 4, 7 & 8 62 3 & 4, 7 & 8 63 (3 & 4) , ( 7 & 8) 64 (3 & 4) , ( 7 & 8) 65 (3 & 4) , ( 7 & 8) 66 (3 & 4) , ( 7 & 8) 67 3 & 4, 7 & 8 68 2 & 4, 7 & 8 69 2 & 4, 1, 7 & 8 70 (2 & 4) , ( 7 & 8) 71 (2 & 4) , ( 7 & 8) 72 2 & 4, 7 & 8 73 (2 & 4) , ( 7 & 8) 80 2 & 4, 6 & 8 2 Connected Terminals NONE NONE OFF OFF OFF 3 (Lock location) 1 & 2, 5 & 6 OFF ON ON (ON) (ON) OFF, OFF 2, 3 & 7 (1,2 & 8), (4,5&6) 2, 4 & 8 2&3 2&3 2&3 2&3 2&3 2&3 2&3 2&3 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 3, 6 & 7 2 & 4, OFF 2 & 4, OFF 2 & 4, 5 & 7 2 & 4, 5 & 7 2 & 4, 5 & 7 2 & 4, OFF 2 & 4, OFF 1&2 OFF 1&2 OFF (1 & 2) (OFF) (OFF) 1&2 1 & 2, 5 & 6 OFF, OFF 1 & 2, 5 & 6 OFF, OFF (1 & 2), (5 & 6) (OFF, OFF) (OFF, OFF) OFF, OFF OFF, OFF (1 & 2), (5 & 7) 1 & 2, 5 & 7 1 & 2, 5 & 7 OFF, OFF OFF, 5 & 6 3 RATING6 .4VA @ 28VDC Resistive 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings 15A 24V 20A 18V 20A 12V 15A 12V 20A 6V 20A 3V 13 Legend Orientation Lock above terminals 10 & 9. 7 LAMP Above terminals 12 & 11 No lamp Incandescent LED* 2VDC 6VDC 12VDC 24VDC 0 4 3V Red A B C D 5 6V Amber L M N P 6 12V Green F G H J 7 18V * Consult factory for "daylight bright", blue/green and white LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR1 J Black 9 ACTUATOR STYLE AND COLOR1 Black Red P R Locking Rocker 10 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. 0 - No Actuator Clear White 1 7 3 9 Z - No Lens Amber Green B G C H D J E K Red M N P R Blue T Large Transparent U Large Translucent V Bar Transparent W Bar Translucent 11 LOCK FUNCTION AND COLOR Locking Position Down H J K L M Up A B C D E Up & Down R S T U V Center3 1 2 3 4 5 Lock Color Match Actuator Black White Red Safety Orange 13 LEGEND ORIENTATION 0 1 2 3 4 5 ILLUMINATION2 Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only. Lamps Illumination Type Lamp wired to Terminals Independent 8 24V 00 No legend this location / no actuator For legend options & codes, see pages 54-65 of the Carling Transportation catalog. .250 (6.4mm) TAB (QC) .187 (4.7mm) TAB (QC) NONE #2 12 Legend 12 LASER ETCH, LENS OR BODY LEGEND 4 TERMINATION4,5 S B 11 Lock 12+ 11- ORIENTATION OF ACTUATOR/LENS IN PANEL No legend (used with codes 11-18 in selection 12) Orientation 1 - vertical, lamp 1 on top Orientation 2 - horizontal, lamp 1 on right Orientation 3 - vertical, lamp 1 on bottom Orientation 4 - vertical, lamp 1 on left ORIENTATION 1 LOCK P LOCK PZAY2-2 LOCK P P P P LOCK LOCK P PZAY2-1 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Additional lamp circuits available. Consult factory. 3 Available only with 3 position circuits. 4 Termination 1 not available with rating 4. 5 Termination 3 only available with ratings 1, B and E. 6 Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com LOCK ORIENTATION 3 ORIENTATION 2 Terminal Orientation 1 3 10 Lens 6 LOCK 2 CIRCUIT6 1 4 B C D E G H 9 Actuator ORIENTATION 4 1 Series | 11 * Intentionally left blank 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue * Plainville, CT 06062-1177 Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com East Region Sales Office, CT * ersm@carlingtech.com Midwest Region Sales Office, IL * mrsm@carlingtech.com West Region Sales Office, CA * wrsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 * Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China * shenzhen@carlingtech.com Shanghai, China * shanghai@carlingtech.com Pune, India * india@carlingtech.com Kaohsiung, Taiwan * taiwan@carlingtech.com Yokohama, Japan * japan@carlingtech.com Europe/Middle East/Africa Headquarters Carling Technologies, Ltd., Devon, England 06062-1177 Int + 44 1392-364422 * Fax: Int + 44 1392-364477 Email: ltd.sales@carlingtech.com GmbH, Germany * gmbh@carlingtech.com SAS, France * sas@carlingtech.com REV_SW_L_0612