www.vishay.com For technical questions contact: ff3dresistors@vishay.com Document Number: 28749
3Revision: 25-Feb-05
SVR37
Vishay BCcomponents Standard High Ohmic/
High Voltage Resistors
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
sched ule of “IEC pub lication 60115-1, c ategory LCT/ UCT/56
(rated temperature range: Lower Category Temperature,
Upper category Temperature, damp heat, long term, 56
days). T he testi ng also cover s the requ iremen ts spe cified by
EIA and EIAJ.
The tests are carried out in accordance with IEC publication
60068-2. “Recommended basic climatic and mechanical
robustness testing procedure for electronic components”
and und er standard atmospheric conditions a ccording to IEC
60068-1, subcl aus e 5.3.
In the Test Procedures and Requirements table the tests and
requirements are listed with reference to the relevant
clauses of IEC publications 60115-1 and 60 068-2; a short
description of the test procedure is also given. In some
instances deviations from the IEC recommendations were
necessary for our meth od of s pecifying.
All soldering tests are performed with mildly activated flux.
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
TEST PROCEDURE REQUIREMENTS
4.16 21 (U) robustness of
terminations:
4.16.2 21 (Ua1) tensile all samples load 10N; 10s number of failures: < 10 x 10-6
4.16.3 21 (Ub) bending half number
of samples load 5N; 4 x 90° number of failures: < 10 x 10-6
4.16.4 21 (Uc) torsion other half
number of samples 3 x 360° in opposite
directions no damage, ∆R/R max.: ± (1 % + 0.05 Ω)
4.17 20 (Ta) solderability 2 s; 235°C good tinning; no damage
4.18 20 (Tb) resistance to soldering
heat thermal shock; 3 s;
350 °C; 3mm from body
∆R/R max.: ± (2 % + 0.05 Ω)
4.19 14 (Na) rapid change of
temperature 30 minutes at - 55 °C and
30 minutes at + 155 °C; 5
cycles
∆R/R max.: ± (2 % + 0.1 Ω)
4.23 climatic sequence:
4.23.2 2 (Ba) dry heat 16 h; 155 °C
4.23.3 30 (Db) damp heat
(accelerated) 1 st cycle 24 h; 55 °C;
90 to 100 % RH
4.23.4 1 (Aa) cold 2 h; - 55 °C
4.23.5 13 (M) low air pressure 2 h; 8.5 kPa; 15 - 35 °C Rins min.: 103 MΩ
4.23.6 30 (Db) damp heat,
(accelerated)
remaining cycles
5 days; 55 °C;
95 to 100 % RH;
∆R/R max.: ± (2 % + 0.1 Ω)
4.24.2 3 (Ca) damp heat,
(steady state) 56 days; 40 °C;
90 to 95 % RH; dissipation
0.01 Pn; limiting voltage
100V (DC)
∆R/R max.: ± (5 % + 0.1 Ω)
4.25.1 −endurance at 70 °C 1000 h loaded with Pn or
Vmax
∆R/R max.: ± (5 % + 0.1 Ω)
4.8.4 −temperature coefficient between - 55 °C t o + 155 °C;
(TC ppm/°C)
≤ ± 350