Connector Terminal Boxes XW3B Series Includes New Lightweight, Low-profile Connector Terminal Boxes for Use Outside of Control Boxes to Centralize Sensor I/O Connectors with Reduced Labor and Greater Environmental Resistance Tough model with a significantly lower profile satisfies IP67. Available for Photoelectric Sensors, Proximity Sensors, and Limit Switches with Sensor I/O Connectors (M12). Increased rated current, with added ground terminal, and compatible with valves and solenoids. Incorporates power and operation indicators. Uses a single mounting method regardless of the number of ports, which ensures easy system expansion. Sensor Controllers/ Related Products Digital Panel Meters Power Supplies Sensor Controllers Ratings and Specifications Rated current 4 A/port (signal lines) 12 A/box (power lines) Rated voltage 10 to 30 VDC Contact resistance 40 M max. (with 100 mA max., 20 mV max.)*1 Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 500 VAC for 1 min (leakage current: 1 mA max.)*2 Degree of protection IP67 (IEC529) Cable retention force 98 N/15 s Insertion tolerance 200 times Operating temperature -25 to 70C Connectors *1. The contact resistance of the Connector. *2. The dielectric strength of the Connector. Peripheral Devices Compatible Connectors XS5/XS2 /XW3 XS2 XN2 XW3B XS2G Connector Plug Assemblies (crimping, soldering, or screw-on) XS2W Connectors on cable ends (Sockets or Plugs) XS2H Connectors on one cable end (Plugs) Materials and Finish Item Connectors Part name Anchor Contacts Brass/nickel base, 0.4-m gold plating Cable Sheath color: gray Core size: AWG18/AWG22 * XS3 Cable XS5 Case Materials and finish Brass/nickel plated Case PBT resin (UL94V-0)/light gray Bushing Rubber PCB Glass-epoxy board Seal resin Urethane resin * The positive power supply, negative power supply, and ground lines are AWG18. Signal lines are AWG22. 1344 XW3B XW3B Connector Terminal Box Dimensions (Unit: mm) XW3B-P45@-@11 (Four Input Ports) Power indicator (green LED) Operation indicator (red LED) 73 e, 4.5 4.5 dia. Thre 12 34 6.9 dia. 27 33 54 L 100 10 120 9 9 27 82 30.5 Internal connection indication 14 dia. 6.5 13.5 20 9 9 XW3B-P65@-@11 (Six Input Ports) Power indicator (green LED) Operation indicator (red LED) 73 e, 4.5 4.5 dia. Thre 12 34 56 7.7 dia. 27 33 54 100 L 10 Sensor Controllers/ Related Products 120 9 27 9 dia. 27 100 30.5 Internal connection indication 14 dia. 6.5 Digital Panel Meters 20 13.5 9 4.5 dia. XW3B-P85@-@11 (Eight Input Ports) Power Supplies Power indicator (green LED) Operation indicator (red LED) 73 e, 4.5 4.5 Sensor Controllers dia. Thre Connectors 12 34 56 27 7 8 8.2 dia. 33 54 L 100 10 120 Peripheral Devices 9 27 27 27 30.5 127 14 dia. 9 dia. Internal connection indication 6.5 20 13.5 9 4.5 dia. XS5/XS2 /XW3 XS2 XN2 XW3B XS3 XS5 1345 XW3B Ordering Information Sensor type and connections 3-wire DC NPN/2-wire DC 3-4 2-wire DC1-4/ without polarity 3-4 3-wire DC PNP/2-wire DC 1-4 Actuator connections 1-4 --- Actuator connections 3-4 Actuator connections No. of ports Cable length (m) 4 5 XW3B-P445-G11 Model XW3B-P452-G11 Model XW3B-P453-G11 Model 6 5 XW3B-P655-G11 XW3B-P652-G11 XW3B-P653-G11 8 5 XW3B-P855-G11 XW3B-P852-G11 XW3B-P853-G11 Note: Here 1-4 and 3-4 are connector pin numbers. Connection Diagrams Standard Japanese Specification XW3B-P@55-@11 for 3-wire DC NPN, 2-wire DC (without polarity 3-4), and Actuator (1-4) 3-WIRE NPN Positive power supply (Brown) Negative power supply (Blue) Ground (Green/Yellow) Connector pin number Power indicator (Green LED) 1 Signal 1 1 (White) Sensor Controllers/ Related Products Lead color Signal 2 (Green) 4 2 1 4 5 2 4 Signal 4 4 (Gray) 4 Signal 5 5 (Pink) 4 Signal 6 6 (Red) 4 Signal 7 7 (Black) 4 Signal 8 (Purple) 4 5 2 Connectors 5 2 XS5/XS2 /XW3 XS2 XN2 XW3B XS3 XS5 1346 Signal 1 1 (White) 5 2 Signal 2 2 (Green) 8 Signal 3 3 (Yellow) Signal 4 4 (Gray) Signal 5 5 (Pink) Signal 6 6 (Red) Signal 7 7 (Black) 2 5 Signal 8 8 (Purple) 3 The above wiring diagrams are for eight-port use. Figures in parentheses indicate lead colors. The expression "white/red" means white and red stripes. Here 1-4 and 3-4 are pin numbers. Signal 1 1 (White) Signal 2 (Green) 4 1 4 5 Signal 3 3 (Yellow) 4 5 Signal 4 4 (Gray) 4 Signal 5 5 (Pink) 4 5 Signal 6 6 (Red) 4 5 Signal 7 7 (Black) 4 5 Signal 8 8 (Purple) 4 3 5 2 1 2 5 2 3 1 2 5 2 3 1 2 5 2 3 1 1 4 2 3 1 4 5 1 2 1 4 2 3 1 4 5 3 1 4 2 3 Operation indicator (Red LED) 2 5 1 2 3 2 Ground (Green/Yellow) Connector pin number 1 4 3 5 5 3 2 Negative power supply (Blue) Power indicator (Green LED) Lead color 3 2 Positive power supply (Brown) 1 2 1 4 3 5 5 3 Operation indicator (Red LED) 3 5 3-WIRE PNP 1 4 3 1 Note: 1. 2. 3. 4. Power indicator (Green LED) 3 1 Peripheral Devices Ground (Green/Yellow) Connector pin number 3 1 Sensor Controllers Negative power supply (Blue) 3 1 Power Supplies Positive power supply (Brown) 3 1 Signal 3 3 (Yellow) European Specification XW3B-P@53-@11 for 3-wire DC PNP, 2-wire DC (with polarity 1-4), and Actuator (3-4) 2-WIRE 3 1 Digital Panel Meters Note: Cannot be used with NPN-type Photoelectric and Proximity Sensors. Cannot be used with Proximity Sensors with polarity 3-4. Lead color 3 Operation indicator (Red LED) 2 5 Japanese Specification XW3B-P@52-@11 for 2-wire DC (with polarity 1-4, without polarity 3-4) 2 5 3 2 XW3B Mounting Holes (Unit: mm) Three, M4 or 4.5 dia. 330.1 730.1 Note: Mounting hole dimensions are always the same regardless of the number of ports. Safety Precautions Refer to Warranty and Limitations of Liability on page F-2. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Connector Connection or Disconnection * Before using a Sensor or Limit Switch, check this catalog and be sure that the Sensor or Limit Switch can be connected. * Be sure to turn OFF the power supplied to the XW3B before Connector connection or disconnection. * Do not touch the engaged side of any Connector with a wet hand. * If a Connector is wet with water, wipe the Connector and be sure that the connector is completely dry. * Be sure that there is no metal plate or powder on the engaged side of any Connector. Cable Connection * Be sure to wire the cable correctly according to the wiring diagram so that the blue wire will be connected to the negative power supply terminal and the brown wire will be connected to the positive power supply terminal. * If there is any wiring mistake, the load will not operate or the operation indicator will not light. * Be sure to connect a load to the signal lines to operate the Sensor and Actuator. Applicable Connectors * Applicable Connectors are the XS2G (assembly type), XS2H (monoblock type), and XS2W (monoblock type). * After a Connector is engaged, tighten the Connector securely with a mounting bracket. * Be sure to put the XS2Z-12 Waterproof Cover or XS2Z-15 Dust Cover on any Connector that is not used. Power Supply and Operation Indicators * When power is supplied, the green power indicator will be lit. When the Sensors and Actuators are operating, the corresponding red operation indicators will be lit. * Only DC Sensors and Actuators can be connected to the XW3B. Do not connect AC Sensors or Actuators. * Connector Terminal Boxes are internally wired with 2 or 3 wires. The type is marked on the case. 3-WIRE NPN 3-WIRE PNP Sensor Controllers/ Related Products 2-WIRE Digital Panel Meters Power Supplies Sensor Controllers Connectors Peripheral Devices XS5/XS2 /XW3 XS2 XN2 XW3B XS3 XS5 1347 XW3B Input Device Connections Using Sensor I/O Connectors Direct Connection Type Proximity Sensor Limit Switch Photoelectric Sensor XS2W Cable with connector Connector-Terminal Connection Type Pre-wired Type Proximity Sensor Limit Switch Photoelectric Sensor Proximity Sensor Limit Switch Photoelectric Sensor XW3B Connector Terminal Box XW3B Connector Terminal Box XS2G Connector Assembly (solderless/soldering type) XW3B Connector Terminal Box Input Devices Using Sensor I/O Connectors Connector Terminal Box Cable Input devices using Sensor I/O Connectors --- 2-wire DC Proximity Sensor XS2W-D42@-@81-A 3-wire DC Proximity Sensor (NPN) XS2W-D42@-@81-A Photoelectric Sensor (NPN) XW3B-P@55-G11 Sensor Controllers/ Related Products --- Limit Switch XS2W-D42@-@81-A Digital Panel Meters Power Supplies XS2W-D42@-@81-A 3-wire DC Proximity Sensor (PNP) XS2W-D42@-@81-A Photoelectric Sensor (PNP) XW3B-P@53-G11 Sensor Controllers Connectors --2-wire DC Proximity Sensor Peripheral Devices XW3B-P@52-G11 XS2W-D42@-@81-A XS5/XS2 /XW3 --Limit Switch XS2 XS2W-D42@-@81-A XN2 XW3B XS3 XS5 1348 Connector-Terminal E2E-X3D1-M1J-T, E2E-X7D1-M1J-T, connection type E2E-X10D1-M1J-T Direct connection type E2E-X@D1-M1 E2E-X2E1-M1, E2E-X5E1-M1, E2E-X10E1-M1 Direct connection type E2E-X5ME1-M1, E2E-X10ME1-M1, E2E-X18ME1-M1 E3S-AT16, E3S-AT66, E3S-AD16, E3S-AD17, E3S-AD18, E3S-AD66, Direct connection type E3S-AD67, E3S-AD68, E3S-AR16, E3S-AR66 Connector-Terminal WL@-@DK1EJ@ *1, WL@-@-M1GJ *1, connection type D4C-@0@@-DK1EJ@ *2 Direct connection type WL@-@K13 *1, D4E-@@10N *2 E2E-X2F1-M1, E2E-X5F1-M1, E2E-X10F1-M1 Direct connection type E2E-X5MF1-M1, E2E-X10MF1-M1, E2E-X18MF1-M1 E3S-AT36, E3S-AT86, E3S-AD36, E3S-AD37, E3S-AD38, E3S-AD86, Direct connection type E3S-AD87, E3S-AD88, E3S-AR36, E3S-AR86 E2E-X3D1-M1GJ, E2E-X3D1-M1J-T, E2E-X7D1-M1GJ, E2E-X7D1-M1J-T, E2E-X10D1-M1GJ, E2E-X10D1-M1J-T Connector-Terminal E2E-X8MD1-M1GJ, E2E-X14MD1-M1GJ, connection type E2E-X20MD1-M1GJ E2EQ-X3D1-M1GJ, E2EQ-X7D1-M1GJ, E2EQ-X10D1-M1GJ E2E-X3D1-M1G, E2E-X7D1-M1G, E2E-X10D1-M1G Direct connection type E2E-X8MD1-M1G, E2E-X14MD1-M1G, E2E-X20MD1-M1G Connector-Terminal WL@-@DK1EJ@ *1, WL@-@-M1GJ *1, connection type D4C-@0@@-DK1EJ@ *2 WL@-@K13 *1, D4E-@@10N *2, Direct connection type D4CC-@@@@ *2 Note: Use the XS2G Connector assembly in combination with a pre-wired input device. *1. Any of these models is available provided that only its SPST-NO contact is used. *2. Any of these models is available provided that it uses an NO connection. XW3B Attaching the XS2G Connector to Pre-wired Input Device Input devices and connector pin number Connector Terminal Box 3-wire DC (NPN) 1: +, 3: -, 4: output 2-wire DC (with polarity) 1: +, 4: - 2-wire DC (with polarity) 3: -, 4: + 2-wire DC (with no polarity) 3, 4 Limit Switch 3-wire DC (PNP) 1: +, 3: -, 4: output XW3B-P@55-G11 Yes No Yes Yes Yes No XW3B-P@53-G11 No Yes No No No Yes XW3B-P@52-G11 No Yes No Yes Yes No Connector Terminal Boxes for Input Devices with Sensor I/O Connectors Input device Connection method Type Photoelectric Sensors NPN Direct connection type PNP Connector-Terminal connection type 2-wire DC 3-wire DC Proximity Sensors NPN Direct connection type PNP Connector-Terminal connection type Limit Switches Direct connection type Model E3S-AT16/66, E3S-AR16/66, and E3S-AD16/17/18/66/67/68 E3S-AT36/86, E3S-AR36/86, and E3S-AD36/37/38/86/87/88 E2E-X@D1-M1J-T E2E-X@D1-M1GJ and E2E-X@D1-M1J-T E2E-X@MD1-M1GJ E2EQ-X@D1-M1GJ E2E-X@D1-M1G E2E-X@MD1-M1G E2E-X@D1-M1 E2E-X@E1-M1 E2E-X@ME1-M1 E2E-X@F1-M1 E2E-X@MF1-M1 WL@-@DK1EJ@ *1, WL@-@-M1J *1, and D4C-@0@@-DK1EJ@ *2 WL@-@K13 *1 and D4E-@@10N *2 D4CC-@@@@ *2 Cable Connector Terminal Box XW3B-P@55-G11 XW3B-P@53-G11 XW3B-P@55-G11 XW3B-P@52-G11 XS2W-D42@-@81-A XW3B-P@55-G11 XW3B-P@53-G11 XW3B-P@52-G11, XW3B-P@55-G11 XW3B-P@52-G11 *1. Any of these models is available provided that only its SPST-NO contact is used. *2. Any of these models is available provided that it uses an NO connection. See the models above for components that are compatible with Sensor I/O Connectors. Sensor Controllers/ Related Products Digital Panel Meters Power Supplies Sensor Controllers Connectors Peripheral Devices XS5/XS2 /XW3 XS2 XN2 XW3B XS3 XS5 Cat. No. G802-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1349 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: XW3B-P853-G11 XW3B-P452-G11 XW3B-P855-G11 XW3B-P652-G11 XW3B-P455-G11 XW3B-P852-G11 XW3B-P453-G11 XW3B-P655-G11