TS SERIES
50 TO 250 mA
MEETS MIL-R-28750/5,6, & 7
FEATURES
Hermetically sealed TO-5 package
Transformer coupled
High speed switching
TS5-1Y switches AC or DC
INPUT CHARACTERISTICS
INPUT VOLTAGE RANGE
4.0 – 7.0 Vdc
MAXIMUM TURN-ON VOLTAGE
5.0 Vdc
MINIMUM TURN-OFF VOLTAGE
1.0 Vdc
I/O DIELECTRIC
1000 Vac pk-pk
OUTPUT CHARACTERISTICS
MAX. OUTPUT CURRENT
(CONTINUOUS, 25°C)
50 mAac or mAdc (TS5-1Y)
250 mAdc (TS6-1Y)
100 mAdc (TS7-1Y)
MAX. OUTPUT VOLTAGE
40 Vac or Vdc (TS5-1Y)
40 Vdc (TS6-1Y)
250 Vdc (TS7-1Y)
MAX. ON-RESISTANCE
5 ohms (TS5-1Y)
TURN-ON TIME TURN-OFF TIME
10 µsec. 15 µsec.
ENVIRONMENTAL CHARACTERISTICS
SHOCK
1500 G’s, 0.5 ms.
VIBRATION
100 G’s, 10 to 2000 Hz
OPERATING AMBIENT TEMPERATURE
-55 to +125°C
DC SOLID STATE RELAYS
1
CONTROL
SOURCE
DC SUPPLY
3
75
+
+
1
CONTROL
SOURCE
AC OR ± DC SUPPLY
3
75
LOAD
LOAD
46
SOLID STATE RELAYS
Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. ©2003 by Tyco Electronics Corporation
TERMINAL VIEW
47
SOLID STATE RELAYS
Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. ©2003 by Tyco Electronics Corporation
DC SOLID STATE RELAYS
EW
.335 DIA MAX (8.51)
-60 -40 -20 20 40 60 80 100 120 140
10
20
30
40
50
60
70
80
400
90
300
200
100
-60 -40 -20 20 40 60 80 100 120 140
10
20
30
40
50
60
70
80
400
90
300
200
100
-60 -40 -20 20 40 60 80 100 120 140
1
2
3
4
5
6
7
8
9
10
20
30
40
50
60
70
80
100
90
OUTPUT CURRENT (mA)
OUTPUT CURRENT (mA)
OUTPUT CURRENT (mA)
–55°C
–125°C
–55°C
–125°C
–55°C
–125°C
.370 DIA MAX (9.40)
.275 MAX
(12.70)
.50 MIN
(12.70)
.017 DIA (0.43)
.100
(2.54)
.200
(5.08)
.031
.032
(REF)
(0.81)
45°
0
6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
4 Vdc INPUT
7 Vdc INPUT
6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
7 Vdc INPUT
0
6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
4 Vdc INPUT
7 Vdc INPUT
0
4 Vdc INPUT
AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C)
TS5/TS6/TS7
OUTPUT CURRENT VS. INPUT CONTROL VOLTAGE AND AMBIENT TEMPERATURE
TS5-1Y TS6-1Y TS7-1Y
NOTES: 1) Reversing polarity of input (or output except for TS5-1) may cause per-
manent damage. 2) Input must be a step function. Rise or fall time, as applicable,
not to exceed 100 µsec. 3) Inductive loads must be diode suppressed. 4) For any
control voltage, the maximum load current shown on graphs must not be exceeded.
Attempting to draw currents in excess of those specified on graphs can cause per-
manent damage.