SPECIFICATION CONTROL DRAWING MATERIALS 1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked polyvinylidene fluoride. 2. SHIELD: Solder impregnated, flux coated copper wire braid. SOLDER: TYPE Sn63 per ANSI/J-STD-006. FLUX: TYPE ROM1 per ANSI/J-STD-004. 3. MELTABLE SEALING RING: Immersion resistant thermoplastic. APPLICATION 1. This part is designed to terminate a tin or silver-plated copper braid to a Tyco Electronics D(K)-621 connectors. Cable braid may be round or flat. Braid Diameter: 2.54 [0.100] min; 5.08 [0.200] max. 2. Part maybe installed using Tyco Electronics-approved infrared or hot-air heaters. Tyco Electronics Corporation 300 Constitution Drive, Menlo Park, CA. 94025, U.S.A. TITLE: Raychem Unless otherwise specified dimensions are in millimeters. [Inches dimensions are shown in brackets] TOLERANCES: 0.00 N/A 0.0 N/A 0 N/A ANGLES: N/A ROUGHNESS IN MICRON Tyco Electronics reserves the right to amend this drawing at any time. Users should evaluate the suitability of the product for their application. SOLDERSHIELD BRAID TERMINATOR WITH SEAL DOCUMENT NO.: B-070-84 PROD. REV.: A PREPARED BY: DCR NUMBER: REPLACES: CAGE CODE : mforonda D050141 D030376 06090 (c) 2005 Tyco Electronics Corporation. All rights reserved. If this document is printed it becomes uncontrolled. Check for the latest revision. DOC. ISSUE: 2 SCALE: --- DATE: 19-May-05 SIZE: A SHEET: 1 of 1