FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 AC Filter 2-Stage, Broad Band Attenuation Quick connect terminals 6.3x0.8 mm Case MF Quick connect terminals 6.3x0.8 mm Case 09 Description - Chassis: Screw-on mounting, from top - Line filter in standard and medical version, 2 stages - 3 designs: Design C, Design D, Design F - Quick connect-, wired- or bolt terminals - High symmetrical and asymmetrical attenuation in the frequency range of 100kHz up to 300MHz Approvals - VDE Certificate Number: 40030410 - UL File Number: E72928 Bolt and nut M4 Case MB Characteristics - Designed for current applications of 1 - 36 A - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Version with wire connection References Alternative: Standard version Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Material: Housing 1 - 36 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 30 A @ Ta 40 C / 125/250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical (M5) < 5 A resp. (M80) < 80 A (250 V / 60 Hz) 1.7 kVDC between L-N 2.75 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21 acc. to IEC 60068-1 from rear-side IP 20 IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminal 6.3 x 0.8 mm Bolt and nut M4 Aluminum Line Filter MTBF Standard and Medical Version, IEC 60939, UL 1283 ed.5, CSA C22.2 no. 8 Technical Details > 200'000 h acc. to MIL-HB-217 F EMC Products 1 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Dimension Case 09 with quick connect terminals max. 77 max. 46 max. 52 17.5 3.5 12 max. 31 27 6.3x0.8 (5x) 4.8 0.3 (2x) 60.4 0.5 1) 2) 1) Line 2) Load Case MB with quick connect terminals max. 58 max. 155 max. 46 12 max. 156 144 0.5 140 0.5 5.3 0.3 (2x) 6.3x0.8 (5x) 1) 1) Line 2) Load 2 EMC Products 2) 7.7 15.2 max. 131 27 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Case MB with bolt and nut M4 max. 160 27 max. 58 max. 131 15.2 max. 46 5) 12 13 4) max. 156 144 0.5 140 0.5 1) 2) M4 (4x) 4) 5.3 0.3 (2x) 3) 1) Line 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE; M4x16; 1.2...1.5 Nm, keep lock-nut fastened Case MC with quick connect terminals max. 51 max. 66 11.6 3.5 12 max. 31 27 max. 90 75 0.5 5.3 0.3 (2x) 6.3x0.8 (5x) 1) 2) 1) Line 2) Load EMC Products 3 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Case MD with quick connect terminals max. 51 max. 66 11.6 12 3.5 max.41 27 max. 90 75 0.5 5.3 0.3 (2x) 6.3x0.8 (5x) 1) 2) 1) Line 2) Load Case ME with quick connect terminals max. 52 max. 112 12 12 max. 46 max. 87 max. 115 104.5 0.5 97.5 0.5 5.3 0.3 (2x) 6.3x0.8 (5x) 1) 1) Line 2) Load 4 EMC Products 2) 3.5 27 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Case MF with quick connect terminals max. 85 max. 98 40 21.6 15.6 max. 59 max. 123 max. 120 109 6.3x0.8 (5x) 4.4 0.3 0.3 2) 54.5 0.5 1) 47.5 0.5 (4x) 1) Line 2) Load Case MF with bolt and nut M4 max. 85 max. 98 40 15.6 max. 59 max. 130 max. 120 109 0.3 4.4 0.3 (4x) 3) 2) 54.5 0.5 1) M4 (4x) 4) 47.5 0.5 5) 1) Line 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE; M4x16; 1.2...1.5 Nm, keep lock-nut fastened EMC Products 5 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Case with wire leads 140 5 140 5 L 3) 1) PE 4) N 2) L' 3) N' 5) 5) 1- 3 A 6 - 10 A 12 - 16 A 20 A 25 - 30 A 36 A AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 AWG 10 1) Line 2) Load 3) Brown 4) Yellow-Green 5) Blue Diagrams Design C and D Design F 1) 2) 1) Line, 2) Load Bleeding resistor R = 1 M Medical (M5) without Cy 6 EMC Products 1) 2) FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Attenuation Loss . . . . . 0.1/100 differential mode ........... 100/0.1 differential mode - - - - differential mode _____ common mode 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C 12 A / Design C 16 A / Design C 20 A / Design C 30 A / Design C 1 A / Design D 3 A / Design D 6 A / Design D 10 A / Design D 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 1 A / Design F 3 A / Design F 6 A / Design F 10 A / Design F 12 A / Design F 16 A / Design F Standard version EMC Products 7 FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Medical version (M5) 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C 12 A / Design C 16 A / Design C 20 A / Design C 30 A / Design C 1 A / Design D 3 A / Design D 6 A / Design D 10 A / Design D 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 1 A / Design F 3 A / Design F 6 A / Design F 10 A / Design F 12 A / Design F 16 A / Design F 8 EMC Products FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Medical version (M80) 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C 12 A / Design C 16 A / Design C 20 A / Design C 30 A / Design C 1 A / Design D 3 A / Design D 6 A / Design D 10 A / Design D 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 1 A / Design F 3 A / Design F 6 A / Design F 10 A / Design F 12 A / Design F 16 A / Design F All Variants Rated current Filter-Type Terminal Design [A] L L1 Cx Cy Ri Power Loss Weight [mH] [mH] [F] [nF] [m] [W] [g] Housing Packaging Order Number [ST] 1 Standard Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 4.7 945 1.9 125 g 09 10 5500.2600.01 3 Standard Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 4.7 120 2.2 130 g 09 10 5500.2601.01 6 Standard Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 4.7 26.2 1.9 130 g 09 10 5500.2602.01 10 Standard Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 4.7 12.9 2.6 200 g MC 10 5500.2603.01 12 Standard Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 4.7 10.1 2.9 200 g MC 10 5500.2604.01 16 Standard Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 4.7 8 4.1 265 g MD 10 5500.2605.01 20 Standard Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 4.7 4.6 3.7 390 g ME 5 5500.2606.01 30 Standard Bolt and nut M4 C 0.6 - 1 10 2.5 4.5 855 g MF 3 5500.2607.03 1 Standard Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 4.7 1320 2.7 165 g MC 10 5500.2610.01 3 Standard Quick connect terminal 6.3 x 0.8 mm D 9.8 - 0.47 4.7 226 4.1 225 g MD 10 5500.2611.01 6 Standard Quick connect terminal 6.3 x 0.8 mm D 7.8 - 1 4.7 55.4 4 350 g ME 5 5500.2612.01 10 Standard Quick connect terminal 6.3 x 0.8 mm D 4.5 - 1 4.7 23.6 4.7 625 g MB 4 5500.2613.01 12 Standard Quick connect terminal 6.3 x 0.8 mm D 3.25 - 1 4.7 16 4.6 630 g MB 4 5500.2614.01 16 Standard Quick connect terminal 6.3 x 0.8 mm D 2.8 - 1 4.7 10.9 5.6 826 g MF 3 5500.2615.01 25 Standard Bolt and nut M4 D 2.0 - 2.2 4.7 4.8 6 830 g MB 4 5500.2616.03 36 Standard Bolt and nut M4 D 1.23 - 2.2 4.7 3.3 8.5 810 g MB 4 5500.2617.03 1 Standard Quick connect terminal 6.3 x 0.8 mm F 22 0.49 0.33 4.7 1200 2.4 180 g MC 10 5500.2620.01 EMC Products 9 FMBB NEO Rated current Filter-Type 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Terminal Design [A] L L1 Cx Cy Ri Power Loss Weight [mH] [mH] [F] [nF] [m] [W] [g] Housing Packaging Order Number [ST] 3 Standard Quick connect terminal 6.3 x 0.8 mm F 9.8 0.16 0.47 4.7 194 3.5 240 g MD 10 5500.2621.01 6 Standard Quick connect terminal 6.3 x 0.8 mm F 7.8 0.11 1 4.7 60 4.3 400 g ME 5 5500.2622.01 10 Standard Quick connect terminal 6.3 x 0.8 mm F 4.5 0.06 1 4.7 21 4.2 645 g MB 4 5500.2623.01 12 Standard Quick connect terminal 6.3 x 0.8 mm F 3.25 0.05 1 4.7 14.6 4.2 695 g MB 4 5500.2624.01 16 Standard Quick connect terminal 6.3 x 0.8 mm F 2.8 0.043 1 4.7 13.7 7 950 g MF 3 5500.2625.01 1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 - 945 1.9 125 g 09 10 5500.2600.04 3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 - 120 2.2 130 g 09 10 5500.2601.04 6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 - 26.2 1.9 130 g 09 10 5500.2602.04 10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 - 12.9 2.6 200 g MC 10 5500.2603.04 12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 - 10.1 2.9 200 g MC 10 5500.2604.04 16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 - 8 4.1 265 g MD 10 5500.2605.04 20 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 - 4.6 3.7 390 g ME 5 5500.2606.04 30 Medical (M5) Bolt and nut M4 C 0.6 - 1 - 2.5 4.5 855 g MF 3 5500.2607.06 1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 - 1320 2.7 165 g MC 10 5500.2610.04 3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 9.8 - 0.47 - 226 4.1 225 g MD 10 5500.2611.04 6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 7.8 - 1 - 55.4 4 350 g ME 5 5500.2612.04 10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 4.5 - 1 - 23.6 4.7 625 g MB 4 5500.2613.04 12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 3.25 - 1 - 16 4.6 630 g MB 4 5500.2614.04 16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 2.8 - 1 - 10.9 5.6 826 g MF 3 5500.2615.04 25 Medical (M5) Bolt and nut M4 D 2.0 - 2.2 - 4.8 6 830 g MB 4 5500.2616.06 36 Medical (M5) Bolt and nut M4 D 1.23 - 2.2 - 3.3 8.5 810 g MB 4 5500.2617.06 1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 22 0.49 0.33 - 1200 2.4 180 g MC 10 5500.2620.04 3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 9.8 0.16 0.47 - 194 3.5 240 g MD 10 5500.2621.04 6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 7.8 0.11 1 - 60 4.3 400 g ME 5 5500.2622.04 10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 4.5 0.06 1 - 21 4.2 645 g MB 4 5500.2623.04 12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 3.25 0.05 1 - 14.6 4.2 695 g MB 4 5500.2624.04 16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 2.8 0.043 1 - 13.7 7 950 g MF 3 5500.2625.04 1 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 0.47 945 1.9 125 g 09 10 5500.2600.07 3 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 0.47 120 2.2 130 g 09 10 5500.2601.07 6 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 0.47 26.2 1.9 130 g 09 10 5500.2602.07 10 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 0.47 12.9 2.6 200 g MC 10 5500.2603.07 12 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 0.47 10.1 2.9 200 g MC 10 5500.2604.07 16 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 0.47 8 4.1 265 g MD 10 5500.2605.07 20 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 0.47 4.6 3.7 390 g ME 5 5500.2606.07 30 Medical (M80) Bolt and nut M4 C 0.6 - 1 0.47 2.5 4.5 855 g MF 3 5500.2607.09 1 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 0.47 1320 2.7 165 g MC 10 5500.2610.07 3 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 9.8 - 0.47 0.47 226 4.1 225 g MD 10 5500.2611.07 6 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 7.8 - 1 0.47 55.4 4 350 g ME 5 5500.2612.07 10 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 4.5 - 1 0.47 23.6 4.7 625 g MB 4 5500.2613.07 12 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 3.25 - 1 0.47 16 4.6 630 g MB 4 5500.2614.07 16 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 2.8 - 1 0.47 10.9 5.6 826 g MF 3 5500.2615.07 25 Medical (M80) Bolt and nut M4 D 2.0 - 2.2 0.47 4.8 6 830 g MB 4 5500.2616.09 36 Medical (M80) Bolt and nut M4 D 1.23 - 2.2 0.47 3.3 8.5 810 g MB 4 5500.2617.09 1 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 22 0.49 0.33 0.47 1200 2.4 180 g MC 10 5500.2620.07 3 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 9.8 0.16 0.47 0.47 194 3.5 240 g MD 10 5500.2621.07 6 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 7.8 0.11 1 0.47 60 4.3 400 g ME 5 5500.2622.07 10 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 4.5 0.06 1 0.47 21 4.2 645 g MB 4 5500.2623.07 12 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 3.25 0.05 1 0.47 14.6 4.2 695 g MB 4 5500.2624.07 16 Medical (M80) Quick connect terminal 6.3 x 0.8 mm F 2.8 0.043 1 0.47 13.7 7 950 g MF 3 5500.2625.07 Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Design 10 C) high symmetrical and asymmetrical noise attenuation EMC Products FMBB NEO 1-Phase AC Filters / DC Filters www.schurter.com/PG84 Rated current Filter-Type Terminal [A] Design L L1 Cx Cy Ri Power Loss Weight [mH] [mH] [F] [nF] [m] [W] [g] Housing Packaging Order Number [ST] D) Excellent high frequency noise attenuation 05.05.2015 F) Excellent low frequency noise attenuation The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 11 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schurter: 5500.2601.01 5500.2605.01 5500.2611.01 5500.2602.01 5500.2606.01 5500.2612.01 5500.2621.01 5500.2625.01 5500.2603.01