CLG-60 60W Single Output LED Power Supply series Features : Universal AC input / Full range High efficiency 89% Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications (Note.2) Compliance to worldwide safety regulations for lighting Damp / wet location outdoor application 3 years warranty 110 F M M MODEL DC VOLTAGE ( except for 48V ) IP67 CLG-60-15 CLG-60-20 CLG-60-24 CLG-60-27 CLG-60-36 CLG-60-48 15V 20V 24V 27V 36V 48V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V RATED CURRENT 5A 4A 3A 2.5A 2.3A 1.7A 1.3A CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~ 3A 0 ~ 2.5A 0 ~ 2.3A 0 ~ 1.7A 0 ~ 1.3A RATED POWER 60W 60W 60W 60W 62.1W 61W 62.5W 2.4Vp-p 1.8Vp-p 2.7Vp-p 2.7Vp-p 3.6Vp-p 4.6Vp-p 14.5 ~ 16.2V 19.5 ~ 22V 24 ~ 26V 25 ~ 30V 32.5 ~ 39V 43.6 ~ 51.8V 88% 89% 89% 11.5 ~ 13V VOLTAGE ADJ. RANGE Fixed can be modified between the range above CURRENT ADJ. RANGE Fixed. Can be modified between 3% ~ -25% rated output voltage VOLTAGE TOLERANCE Note.3 10% LINE REGULATION 3.0% 5.0% LOAD REGULATION 3000ms / 230VAC 5000ms / 115VAC at full load SETUP TIME Note.5 90 ~ 264VAC VOLTAGE RANGE 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC EFFICIENCY(Typ.) 85% AC CURRENT INRUSH CURRENT(max.) 0.8A/115VAC 40A/230VAC OVER VOLTAGE 87.5% 87% 110% (max) 95 ~ 110% OVER CURRENT SHORT CIRCUIT 86% 0.4A/230VAC <0.75mA / 240VAC LEAKAGE CURRENT PROTECTION ( for 48V only) 12V RIPPLE & NOISE (max.) Note.2 2Vp-p INPUT LPS CLG-60-12 CONSTANT CURRENT REGION Note.6 8.4 ~ 12V OUTPUT SELV EQUIVALENT SPECIFICATION Protection type : Constant current limiting, recovers automatically after fault condition is removed Note.4 Hiccup mode, recovers automatically after fault condition is removed 13.8 ~ 16V 17.5 ~ 21V 23 ~ 26V 28 ~ 32V 12V: 90 OVER TEMPERATURE 31 ~ 35V 41 ~ 46V 54 ~ 60V Protection type : Shut down o/p voltage, re-power on to recover 10 15V ~ 48V: 85 (TSW1) detect on heatsink of power transistor 10 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT -30 ~ +70 (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A 495.7Khrs min. MIL-HDBK-217F (25 ) 195.6*61.5*38.8mm (L*W*H) 0.86Kg; 16pcs/14.8Kg/0.54CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:CLG-60-SPEC 2009-11-25 CLG-60 60W Single Output LED Power Supply Mechanical Specification Case No. 957A series Unit:mm 195.6 11.9 7.28 171.8 7.08 9.6 300 20 300 20 +V(Red) -V(Black) 32 32 61.5 AC/L(Brown) AC/N(Blue) FG (Green/Yellow) 18AWG 2C 18AWG 3C 38.8 7.08 7.28 4.2 4PL Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics Ta:25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 15 30 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:CLG-60-SPEC 2009-11-25