Rhopoint Components Ltd Fax: +44 (0) 1883 712938 Phone: +44 (0) 1883 717988 web: www.rhopointcomponents.com e-mail: sales@rhopointcomponents.com
RI-46 Series
RI-46 SRI-46 S
RI-46 SRI-46 S
RI-46 SERIESERIES
ERIESERIES
ERIES
Micro dry-reed switch hermetically sealed in a gas-filled glass envelope.
Single-pole, single-throw (SPST) type, having normally open contacts,
and containing two magnetically actuated reeds.
The switch is of the double-ended type and may be actuated by an
electromagnet, a permanent magnet or a combination of both.
The device is intended for use in relays, sensors, pulse counters or
similar devices.
RI-46 SRI-46 S
RI-46 SRI-46 S
RI-46 SERIESERIES
ERIESERIES
ERIES F F
F F
FEAEA
EAEA
EATURESTURES
TURESTURES
TURES
u Can switch main voltage
u Can handle up to 40 W load
u Contact layers: Gold, sputtered ruthenium
u Superior glass-to-metal seal and blade alignment
u Excellent life expectancy and reliability
GG
GG
GENERALENERAL
ENERALENERAL
ENERAL
DD
DD
DAA
AA
ATT
TT
TAA
AA
A
FORFOR
FORFOR
FOR
ALLALL
ALLALL
ALL
MODELSMODELS
MODELSMODELS
MODELS RI-46 RI-46
RI-46 RI-46
RI-46
AT-Customization / Preformed Leads
Besides the standard models, customized products can also
be supplied offering the following options:
! Operate and release ranges to customer specification
! Cropped and/or preformed leads
CC
CC
COILSOILS
OILSOILS
OILS
All characteristics are measured using the Philips Standard
Coil. For definitions of the Philips Standard Coil and the
standard MIL Coil, refer to “Application Notes” in the
Reed Switch Technical & Application Information Section
of this catalog.
RelaRela
RelaRela
Relationship betwtionship betw
tionship betwtionship betw
tionship between Philips Standareen Philips Standar
een Philips Standareen Philips Standar
een Philips Standard Coil and d Coil and
d Coil and d Coil and
d Coil and Stan-Stan-
Stan-Stan-
Stan-
dardar
dardar
dard MIL Coild MIL Coil
d MIL Coild MIL Coil
d MIL Coil
Operate value of standard MIL Coil = 0.79 x operate value
of Philips Standard Coil + 2.26 AT.
Release value of standard Mil Coil = 0.83 x release value of
Philips Standard Coil + 1.31 AT.
LL
LL
LIFEIFE
IFEIFE
IFE
EXPECTEXPECT
EXPECTEXPECT
EXPECTANCYANCY
ANCYANCY
ANCY
ANDAND
ANDAND
AND
RELIABILITYRELIABILITY
RELIABILITYRELIABILITY
RELIABILITY
The life expectancy data given below are valid for a coil
energized at 1.5 times the published maximum operate
value for each type in the RI-46 series.
No-load conditions (operNo-load conditions (oper
No-load conditions (operNo-load conditions (oper
No-load conditions (operaa
aa
ating frting fr
ting frting fr
ting frequencequenc
equencequenc
equency:y:
y:y:
y: 100 Hz) 100 Hz)
100 Hz) 100 Hz)
100 Hz)
Life expectancy: min. 108 operations with a failure rate of
less than 10-9 with a confidence level of 90%.
End of life criteria:
Contact resistance > 1 after 2 ms
Release time > 2 ms (latching or contact sticking).
Loaded conditions (rLoaded conditions (r
Loaded conditions (rLoaded conditions (r
Loaded conditions (resistiesisti
esistiesisti
esistivv
vv
ve load:e load:
e load:e load:
e load: 20 20
20 20
20 VV
VV
V; 500 mA;; 500 mA;
; 500 mA;; 500 mA;
; 500 mA;
operoper
operoper
operaa
aa
ating frting fr
ting frting fr
ting frequencequenc
equencequenc
equency:y:
y:y:
y: 125 Hz) 125 Hz)
125 Hz) 125 Hz)
125 Hz)
RI-46AARI-46AA
RI-46AARI-46AA
RI-46AA
Life expectancy: min. 107 operations with a failure rate of
less than 10-8 with a confidence level of 90%.
End of life criteria:
Contact resistance > 2 after 2.5 ms
Release time > 2.5 ms (latching or contact sticking).
RI-46A; RI-46B; RI-46CRI-46A; RI-46B; RI-46C
RI-46A; RI-46B; RI-46CRI-46A; RI-46B; RI-46C
RI-46A; RI-46B; RI-46C
Life expectancy: min. 2.5 x 107 operations with a failure
rate of less than 10-8 with a confidence level of 90%.
End of life criteria:
Contact resistance > 2 after 2.5 ms
Release time > 2.5 ms (latching or contact sticking).
Dimensions in inches (mm)
Rhopoint Components Ltd Fax: +44 (0) 1883 712938 Phone: +44 (0) 1883 717988 web: www.rhopointcomponents.com e-mail: sales@rhopointcomponents.com
RI-46 Series
Switching different loads involves different life expectancy
and reliability data. Further information is available on
request.
MM
MM
MECHANICALECHANICAL
ECHANICALECHANICAL
ECHANICAL D D
D D
D
AA
AA
ATT
TT
TAA
AA
A
Contact arrangement is normally open; lead finish is tinned;
net mass is approximately 0.28 g; and can be mounted in
any position.
SS
SS
SHOCKHOCK
HOCKHOCK
HOCK
The switches are tested in accordance with “IEC 68-2-27”,
test Ea (peak acceleration 500 G, half sinewave; duration
11 ms). Such a shock will not cause an open switch (no
magnetic field present) to close, nor a switch kept closed by
an 80 AT coil to open.
VV
VV
VIBRAIBRA
IBRAIBRA
IBRATIONTION
TIONTION
TION
The switches are tested in accordance with “IEC 68-2-6”,
test Fc (acceleration 10 G; below cross-over frequency 57
to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000
Hz, duration 90 minutes). Such a vibration will not cause
an open switch (no magnetic field present) to close, nor a
switch kept closed by an 80 AT coil to open.
MM
MM
MECHANICALECHANICAL
ECHANICALECHANICAL
ECHANICAL S S
S S
S
TRENGTHTRENGTH
TRENGTHTRENGTH
TRENGTH
The robustness of the terminations is tested in accordance
with “IEC 68-2-21”, test Ua1 (load 40 N).
OO
OO
OPERAPERA
PERAPERA
PERA
TINGTING
TINGTING
TING
ANDAND
ANDAND
AND S S
S S
S
TT
TT
TORAORA
ORAORA
ORAGEGE
GEGE
GE
TT
TT
TEMPERAEMPERA
EMPERAEMPERA
EMPERATURETURE
TURETURE
TURE
Operating ambient temperature; min: -55°C; max: +125°C.
Storage temperature; min: -55°C; max: +125°C.
Note:Note:
Note:Note:
Note: Temperature excursions up to 150°C may be permis-
sible. For more information contact your nearest Coto
Technology sales office.
SS
SS
SOLDERINGOLDERING
OLDERINGOLDERING
OLDERING
The switch can withstand soldering heat in accordance with
“IEC 68-2-20”, test Tb, method 1B: solder bath at 350
±10°C for 3.5 ±0.5 s. Solderability is tested in accordance
with “IEC 68-2-20”, test Ta, method 3: solder globule
temperature 235°C; ageing 1b: 4 hours steam.
WW
WW
WELDINGELDING
ELDINGELDING
ELDING
The leads can be welded.
MM
MM
MOUNTINGOUNTING
OUNTINGOUNTING
OUNTING
The leads should not be bent closer than 1 mm to the glass-
to-metal seals. Stress on the seals should be avoided. Care
must be taken to prevent stray magnetic fields from influ-
encing the operating and measuring conditions.
Note 1: Switching higher currents is possible depending on signature of the load.
Model Number RI-46AA RI-46A RI-46B RI-46C
Parameters Test Conditions Units
Ope ra ti ng Charac t e risti cs
Operate Range AT 10.5-19 15-28 24-51 46-70
Release Range AT 4-12 5-16 8-20.5 12-22.5
Opera t e Time - including boun ce (typ.) (energ ization) ms 0. 35 (24 AT) 0. 35 (35 AT) 0. 35 (64 AT) 0. 35 (87. 5 AT)
Bounce Time (typ. ) (energizati on) ms 0. 15 (24 AT ) 0.15 (35 AT ) 0. 15 (64 AT) 0. 15 (87. 5 AT)
Release Time (max) (energization) µs3 0 (24 AT) 30 (35 AT) 30 (64 AT) 30 (87.5 AT)
Resonant Freq uen cy (typ.) Hz 32 00 3200 3200 3200
Electrical Characteristics
Switch ed Pow er (ma x) W 30 30 40 40
Switched Voltage DC (max) V 200 200 200 200
S w itc hed V oltage AC, RMS value ( m ax) V 250 250 2 5 0 250
Switched Current DC (max) note 1 mA 750 1000 1000 1000
Switched Current AC, RMS value (max) note 1 mA 750 1000 1000 1000
Ca rry Curren t DC; AC, RMS value (max) A 2 2. 5 3 3
Breakdown Voltage (min) V 300 400 580 780
Contact Resistance (initial max) (energization) m 90 (27 AT) 90 (27 AT) 90 (36AT) 90 (36 AT)
Contact Resistance (initial typ.) (energization) m 60 (27 AT) 6 0 (27 AT) 60 (36 AT) 60 (36 AT)
Contact Capacitance (max) without test coil pF 0.2 0.2 0.2 0.2
Insulation Resista nce (m in) RH 45% M 106106106106