Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 533945 Coax - Surveillance and CCTV Applications For more Information please call 1-800-Belden1 General Description: Surveillance & CCTV Cable, RG6, Rated-CMG, 18 AWG solid bare copper, foamed polyolefin core, 95% bare copper braid, PVC jacket Usage (Overall) Suitable Applications: Analog Video/CCTV Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (in.) 1 18 Solid BC - Bare Copper .040 Insulation Insulation Material: Insulation Material Dia. (in.) Gas-injected FPE - Foam Polyethylene .180 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Braid BC - Bare Copper 95.000 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 0.266 in. Mechanical Characteristics (Overall) UL Temperature Rating: 75C Bulk Cable Weight: 36 lbs/1000 ft. Max. Recommended Pulling Tension: 69 lbs. Min. Bend Radius/Minor Axis: 2.750 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG NEC Articles: 800 CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 10-14-2013 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 533945 Coax - Surveillance and CCTV Applications EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes PMSHA Specification: P-07-KA110035-MSHA RG Type: 6/U Series Type: Series 6 Flame Test UL Flame Test: UL1685 FT4 Loading C(UL) Flame Test: FT4 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes - Black only. Suitability - Aerial: Yes - Black only. Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/ft) .097 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 16.3 Nominal Velocity of Propagation: VP (%) 83 Nominal Delay: Delay (ns/ft) 1.21 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 6.4 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/1000 ft) 2.700 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1 .24 10 .72 50 1.5 100 2.0 200 2.9 400 4.2 700 5.6 900 6.4 Page 2 of 3 10-14-2013 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 533945 Coax - Surveillance and CCTV Applications 1000 7.0 Max. Operating Voltage - UL: Voltage 300 V RMS Put Ups and Colors: Item # Putup Ship Weight Color 533945 009U1000 1,000 FT 39.000 LB WHITE Notes Item Desc 533945 0091000 1,000 FT 41.000 LB WHITE 533945 010U1000 1,000 FT 39.000 LB BLACK 533945 0101000 1,000 FT 41.000 LB BLACK C RG-6/U COAX 533945 010500 500 FT 21.000 LB BLACK C RG-6/U COAX RG-6/U COAX C RG-6/U COAX RG-6/U COAX Notes: C = CRATE REEL PUT-UP. Revision Number: 5 Revision Date: 03-11-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-14-2013