OUTLET SIDE
INLET SIDE
mm
(INCH)
UNIT:
UNIT : (INCH)
mm
LABEL
82.5 0.3
82.5 0.3
92.0 0.5
92.0 0.5
(3.622 0.020)
(3.248 0.012)
(3.248 0.012)
(3.622 0.020)
25.4 0.5
4.0 0.3
(1.000 0.020)
(0.157 0.012)
4.0 0.3
(0.157 0.012)
10.0
305.0 10.0
(0.394)
(12.008 0.394)
8- 4.5 0.3
(8- 0.177 0.012)
88.0
82.5
(3.465)
(3.248)
(3.248)
(3.465)
88.0
82.5
103.4
( 4.071)
82.5
(3.465)
(3.248)
88.0
(3.248)
(3.465)
88.0
82.5
95.4
( 3.756)
4- 4.5
(4- 0.177) (4- 0.177)
4- 4.5
VH
HH
H
M
L
(M /MIN)
3
Air Flow
0 20.0 40.0 60.0 80.0 (CFM)
0.36
(IN H O)
2
2
(mm H O)
0.30
0.24
0.18
0.12
0.06
0
Air Pressure
AFB0912/24/48X
0 0.5 1.0 2.01.5 2.5
9.0
7.5
6.0
3.0
1.5
0
4.5
31
http://www.deltaww.com
AFB 92 x 92 x 25.4 MM SERIES
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 99g (3.49 oz)
â– DIMENSIONS DRAWING
â– P & Q CURVE (AT RATED VOLTAGE) â– MOUNTING PANEL CUTOUT
MODEL Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power Speed Maximum
Air Flow
Maximum
Air Pressure Noise
PART NO. FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
AFB0912L -R00 / -F00 12 7.0 to 13.8 0.07 0.84
2100 1.050 37.08 2.53 0.100 25.0AFB0924L -R00 / -F00 24 14.0 to 27.6 0.06 1.44
AFB0948L -R00 / -F00 48 28.0 to 56.0 0.05 2.40
AFB0912M -R00 / -F00 12 7.0 to 13.8 0.11 1.32
2450 1.240 43.79 3.25 0.130 30.0AFB0924M -R00 / -F00 24 14.0 to 27.6 0.08 1.92
AFB0948M -R00 / -F00 48 28.0 to 56.0 0.05 2.40
AFB0912H -R00 / -F00 12 7.0 to 13.8 0.16 1.92
2850 1.450 51.21 4.50 0.177 34.0AFB0924H -R00 / -F00 24 14.0 to 27.6 0.10 2.40
AFB0948H -R00 / -F00 48 28.0 to 56.0 0.06 2.88
AFB0912HH -R00 / -F00 12 7.0 to 13.8 0.25 3.00
3200 1.640 57.92 5.62 0.221 38.0AFB0924HH -R00 / -F00 24 14.0 to 27.6 0.13 3.12
AFB0948HH -R00 / -F00 48 28.0 to 56.0 0.08 3.84
AFB0912VH -R00 / -F00 12 7.0 to 13.8 0.40 4.80 3800 1.920 67.80 7.67 0.302 45.0
AFB0924VH -R00 / -F00 24 14.0 to 27.6 0.22 5.28
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Speciîš¿cations are subject to change without notice.