CDM Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Type ST 55 °C Strobe-Flash, Long-Life, 360 & 450 V Aluminum
High Energy, Long-Life
Rugged Type ST capacitors can withstand more than
30 million full discharges in typical strobe-lamp
applications—that’s more than ten years’ operation in
emergency vehicles. This exceptional life capability is
also available in screw-terminal and other case styles
and other capacitance values.
The ST’s magic is its ability to handle the spectrum
of currents caused by full discharge at 1 Hz and faster
rates. Because discharge energy is at frequencies from
less than a hertz to thousands of hertz, power loss and
heating are not predicted by the ESR at 120 Hz, and the
open-structure anode foil of Type ST excels at low loss
over the full spectrum.
Highlights
• Tested to More than 10 Million Flashes
• More than 30 Million Flashes Typical Life
• Snapmount or Solder-Lug Terminals
Specications
Operating Temperature: –40 °C to +55 °C
Rated Voltage: 360 or 450 Vdc
Capacitance: 30 to 300 µF –10% +20%
Leakage Current: 0.01 CV +20 µA at 25 °C
Cold Impedance: –20 °C multiplier of 25 °C Z ≤ 2
Dissipation Factor: 7% maximum @ 25 °C & 120 Hz
Discharge Life: 10 million discharges at 1 s interval, xenon ash tube 0.7 to 1
capacitance ±10%, ESR 150% of limit, DCL 150% of limit
Shelf Life: 500 h @ +55 °C, capacitance ±10%
ESR 150% of limit, DCL 150% of limit
Vibration: 10 to 55 Hz; 0.06” and 10 g max, 6 h vertical, 2 h each, 2 other planes
Outline Drawings
CDM Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Type ST 55 °C Strobe-Flash, Long-Life, 360 & 450 V Aluminum
Terminal Drawings
Snap-In Terminals
Solder-Lug Terminals
Case Dimensions
Diam.(D) Length (L) Terminal
Case Max. Max. Spacing (S) Typical
Code mm Inches mm Inches mm Inches Weight
H04 22 0.87 40 1.57 8.5 0.33 24
J01 25 0.98 25 0.98 10.0 0.39 20
J02 25 0.98 30 1.18 10.0 0.39 24
J03 25 0.98 35 1.38 10.0 0.39 27
J04 25 0.98 40 1.57 10.0 0.39 31
J05 25 0.98 50 1.97 10.0 0.39 38
K03 30 1.18 35 1.38 12.7 0.50 40
K04 30 1.18 40 1.57 12.7 0.50 44
K05 30 1.18 50 1.97 12.7 0.50 53
A05 35 1.38 50 1.97 12.7 0.50 67
A06 35 1.38 63 2.48 12.7 0.50 88
Part Numbering System
ST 121 V 360 J05 2 L
Type Capacitance Tolerance Rated Case Insulation Terminals
300 = 30 µF –10 + 20% Voltage Code 2 = PVC blank = snap-in
121 = 120 µF L = solder lugs
CDM Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Type ST 55 °C Strobe-Flash, Long-Life, 360 & 450 V Aluminum
Typical Performance Curves
Ratings
ESR Max.
Cap. Catalog +25 °C Diameter Length
(µF) Part Number 120 Hz (mm) (in) (mm) (in)
360 Vdc (390 Vdc Surge)
48 ST480V360J012 1.92 25 0.98 25 0.98
60 ST600V360J022 1.54 25 0.98 30 1.18
80 ST800V360J032 1.15 25 0.98 35 1.38
100 ST101V360J042 0.92 25 0.98 40 1.57
120 ST121V360K032 0.77 30 1.18 35 1.38
150 ST151V360J052 0.61 25 0.98 50 1.97
200 ST201V360K052 0.46 30 1.18 50 1.97
250 ST251V360A052 0.37 35 1.38 50 1.97
300 ST301V360A062 0.31 35 1.38 63 2.48
450 Vdc (500 Vdc Surge)
30 ST300V450J012 3.07 25 0.98 25 0.98
40 ST400V450H042 2.30 22 0.87 40 1.57
50 ST500V450J032 1.84 25 0.98 35 1.38
60 ST600V450J042 1.54 25 0.98 40 1.57
80 ST800V450J052 1.15 25 0.98 50 1.97
100 ST101V450K042 1.08 30 1.18 40 1.57
120 ST121V450K052 0.77 30 1.18 50 1.97
150 ST151V450A052 0.61 35 1.38 50 1.97
RoHS Compliant
CDM Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Notice and Disclaimer: All product drawings, descriptions, specications, statements, information and
data (collectively, the “Information”) in this datasheet or other publication are subject to change. The
customer is responsible for checking, conrming and verifying the extent to which the Information con-
tained in this datasheet or other publication is applicable to an order at the time the order is placed. All
Information given herein is believed to be accurate and reliable, but it is presented without any guaran-
tee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability
for certain applications are based on the knowledge that the Cornell Dubilier company providing such
statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards
as typical for such applications, but are not intended to constitute any guarantee, warranty or representa-
tion regarding any such matter – and Cornell Dubilier specically and expressly disclaims any guarantee,
warranty or representation concerning the suitability for a specic customer application, use, storage,
transportation, or operating environment. The Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference
to the use of any Cornell Dubilier products is given gratis (unless otherwise specied by Cornell Dubilier),
and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although
Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design
and manufacturing of its products, in light of the current state of the art, isolated component failures may
still occur. Accordingly, customer applications which require a high degree of reliability or safety should
employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies
or other appropriate protective measures) in order to ensure that the failure of an electrical component
does not result in a risk of personal injury or property damage. Although all product-related warnings,
cautions and notes must be observed, the customer should not assume that all safety measures are indi-
cated in such warnings, cautions and notes, or that other safety measures may not be required.