Power Supplies Silver Line Series - Single & Multi-Output Linears The SolaHD Silver Line Series follows the industry accepted footprint for open frame, linear power supplies. Standard screw terminal connections and optional covers are offered for safety considerations. Applications * Industrial Control Circuits and Components * Instrumentation * Drives * CNC Machinery * Equipment for food industry * Microprocessor Circuits * Analog Circuits * Noise sensitive Circuitry and Sensors Features * Easy-to-install screw terminal connections * Cover options * Industry standard footprint * Universal input and approvals (115/230 Vac) * Low noise, extremely quiet DC output. For noise sensitive or analog circuitry. * Fast transient response. Ideal for test applications. * Built-in OVP on 5 V models and optional on 12, 15 and 24 V models * Automatic resetting overload protection * Short circuit protected E137632 Specifications Parameter * UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 Recognized Component, ITE - UL 60950-1 * Certified, ITE - CSA C22.2 CSA 60950-1 * 100/120/220/230/240 Vac Selectable Input Voltage 47-63 Hz Input Frequency Output Line Regulation for 10% change Load Regulation for 50% change DC Output Adjustment Range All 5-Volt outputs include build-in OVP as standard (setting is 6.2 V 0.4 V) OVP is optionally available on other types at 50% Load Changes 50 msec. Automatic current limit foldback Overload Protection Remote Sensing 0.05% 5% Minimum Overvoltage Protection Transient Response Time 0.05% 3.0 mV maximum Peak-to-Peak Ripple Available to compensate for output voltage drop on selected models. 0.5 Vdc General Operating Temperature Range Derate to 40% at +70C 0 to +50C Storage Temperature Range -25C to +85C Temperature Coefficient (Typical) 0.01% 0C Stability After warm-up .5% For most system applications they will meet requirements of FCC Class B and VDE 0871 for Class B EMI/RFI Linear power supplies have inherently low conducted and radiate noise levels Cover Option Derate power by an additional 15% Cooling Forced air. 20 CFM required for full rating Derate 30% without cooling - IEC60950-1 * RoHS Compliant Limit Input * Two year limited warranty Certifications and Compliances Condition Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018 165 Power Supplies SL Series Selection Table Catalog Number Dimensions - inches (mm) Output 1 Output 2 Output 3 SLS-05-030-1T 5V@3A* 2 - - A SLS-05-060-1T 5 V @ 6 A *2 - - B1 SLS-05-090-1T 5 V @ 9 A *2 - - C SLS-05-120-1T 5 V @ 12 A * - - I2 2 12 V @ 1.7 A 2 or 15 V @ 1.5 A Case - - A SLS-12-034T 12 V @ 3.4 A 2 - - B1 SLS-12-051T 12 V @ 5.1 A 2 - - C SLS-12-068T 12 V @ 6.8 A 2 - - I2 SLS-15-045T 15 V @ 4.5 A 2 - - C SLS-15-060T 15 V @ 6 A 2 - - I2 SLS-24-012T 24 V @ 1.2 A v - - A SLS-24-024T 24 V @ 2.4 A 2 - - B2 SLS-24-036T 24 V @ 3.6 A 2 - - C SLS-24-048T 24 V @ 4.8 A 2 - - I2 SLS-24-072T 24 V @ 7.2 A 2 - - K SLS-24-120T 24 V @ 12.0 A 2 - - L 12 V @ 1 A or 15 V @ .8 A -12 V @ 1 A or -15 V @ .8 - H1 SLD-12-1818-12T 1 12 V @ 1.8 A or 15 V @ 1.5 A -12 V @ 1.8 A or -15 V @ 1.5 A - D SLD-12-3434-12T 12 V @ 3.4 A -12 V @ 3.4 A - I3 SLD-15-3030-15T 15 V @ 3 A 2 -15 V @ 3 A 2 - I3 SLD-12-6034-05T 5 V @ 6 A *2 12 V @ 3.4 A 2 - I1 SLD-12-3015-05T 5 V @ 3 A *2 12 V@ 1.5 A - C1 SLT 12-20404-12T 1 5 V @ 2 A *2 12 V @ .4 A or 15 V @ .4 A -12 V @ .4 A or -15 V @ .4 A H2 5 V @ 3 A *2 12 V @ 1 A or 15 V @ .8 A -12 V @ 1 A or -15 V @ .8 A F 12 V @1.8 A or 15 V @1.5 A -12 V @ 1.8 A or -15 V @ 1.5 A G2 SLS-12-017T 1 SLD-12-1010-12T 1 SLT 12-31010-12T 1 2 5 V @ 6A * 2 SLT 12-61818-12T 1 2 2 2 Case A Over Voltage Protector (OVP) Case B SLO-12-000-1 6.2 V to 34 V Adjustable @ 8 A For Cases B through K J1 SLO-12-000-TB 6.2 V to 34 V Adjustable @ 8 A For Case A or Cases B through K (when used with a cover) J2 Catalog Number Notes: * With Built-In OVP 1. 12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation is field adjustable. 2. With Remote Sense (R.S.) Cover Options Description Catalog Number Description SLCASA-CVR Cover for Case A SLCASI-CVR Cover for Cases I1, I2, & I3 SLCASB-CVR Cover for Case B SLCASK-CVR Cover for Case K SLCASC-CVR Cover for Case C SLCASL-CVR Cover for Case L Note: Covers are sold separately. When used, derate the power supply by 15% of its rated value. 166 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018 Power Supplies Silver Line Dimensions (inches/mm) Case F Cases C and C1 Case G2 Case D AC Input Jumper Connections For use at: 100 Vac 120 Vac 220 Vac 230/240 Vac Connect: 1-3, 2-4 1-3, 2-4 2-3 2-3 Apply AC: 1&5 1&4 1&5 1&4 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018 Cases H1 and H2 167 Power Supplies Silver Line Dimensions (inches/mm) Case J2 Case J1 OVP (OPTIONAL) AC INPUT/DC OUTPUT 13.98" (355) .49" (12.5) 12.99" (330) 1.250" (32) .75" (19) .59" (15) .49" (12.5) 4.87" (124) Cases I1, I2 and I3 4.125" (105) MAX V ADJ. .49" (12.5) Notes: 2.75" (70) 1.250" (32) + OUT Be sure to specify the complete part number when ordering. Orders may be placed with your local SolaHD distributor. - OUT -S +S All dimensions in inches (mm). Dimensions may change and should not be used for construction purposes. .188" (4.8) MTG HOLES (12 PLACES) 4 2 31 5 AC Input WEIGHT: 7.5 LBS. (3.4 KG) .75" (19) PEM NUT HOLES 8-32 MTG (4 PLACES) Case K WEIGHT: 19 LBS. (8.55 KG) AC INPUT/DC OUTPUT 16.85" (428) 15.98" (406) 4.92" (125) 4.13" ( 105) . 375" (9.53) 2.52" (64) V ADJ. . 394" (10) OVP (OPTIONAL) . 236" MTG HOLES (16 PLACES) (6.0) - OUT -S +S + OUT 2.52" (64) . 630 (16) Ma x. 3.46" (88) . 55" (14) 1.34" (34) 5 1 3 24 AC Input Heat Sink . 39" (10) Case L 168 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018