1
Thermal (T- and TA-Line) T11-611
www.schurter.com/PG17_18_19
Circuit Breakers
Circuit Breaker for Equipment thermal, Snap-in type, Reset type, Quick connect terminals
Description
- Snap-in version
- Thermal circuit breaker
- 1-pole
- Reset type
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Compact design
- Positively trip-free release
- Available with cover
- Different mounting possibilities
Standards
- IEC 60934
- UL 1077
- CSA C22.2 No. 235
- GB 17701
Applications
- Power tools
- Household Equipment
- Power supplies and chargers
- Industrial appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
Technical Data
Rated Voltage AC 240 V; 50/60 Hz
Rated Voltage DC 48 V
Rated current range AC 0.05 - 16 A
Conditional short circuit ca-
pacity
IEC: Inc, PC1, AC 240 V: 2 kA
Short circuit capacity Icn at In < 6.5 A/240 VAC : 8 x In
␣ at In ≥ 6.5 A/240 VAC : 96 A
Degree of Protection from front side IP 40 acc. to IEC 60529
Dielectric Strength 50 Hz: > 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
Insulation resistance 500 VDC > 100 MΩ
Endurance typical 2 x Ir: 500 switching cycles
Endurance minimum Reset type
AC : 2 x Ir , cos φ 0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50 switching cycles
Overload IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
␣ UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
Ambient temperature -5 °C to 60 °C
Vibration Resistance ± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Shock Resistance 100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Tripping Type Thermal
Actuation type Reset type
Weight ca. 10 g