LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 1
2 YEAR WARRANTY
NFS40 Series
Single and triple output
5.0 x 3.0 x 1.2 inch package (1U applications)
Industry standard package
Overvoltage and short circuit protection
40W with free air convection
EN55022, EN55011 conducted noise level A
UL, VDE and CSA safety approvals
The NFS40 series is a 40W universal input AC/DC power supply on a 5" x 3" card
with a maximum component height of 1.2" for use in 1U applications. The NFS40
series is available with a wide range of models in the industry standard 5" x 3"
footprint and has proven itself to be highly reliable and versatile product for a wide
range of communication and industrial applications. The NFS40 provides 40W of
output power with free air convection cooling which can be boosted to 50W with
20CFM of air. Standard features include OVP and short-circuit protection. The
series, with full international safety approval and the CE mark, meets conducted
noise EN55022 level A. The NFS40 series is designed for use in low power data
networking, computer, telecom and industrial applications such as hubs, routers,
POS terminals, cable modems, PABX’s, industrial PC’s and machine control.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
GENERAL SPECIFICATIONS
Hold-up time 110VAC, 40 Watts 14ms
230VAC, 40 Watts 110ms
Efficiency 70% typical
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Variable
Approvals and VDE0805, EN60950
standards IEC950, IEC1010, UL1950
(See Note 13) CSA C22.2 No. 950
Weight 280g (9.88oz)
MTBF (See Note 9) MIL-HDBK-217E 170,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating 0°C to +70°C
(See Notes 8, 10) Non-operating –40°C to +85°C
50°C ambient temp., 40W
Convection cooled
Forced air cooling 50W @ 20CFM
50°C to 70°C ambient Derate linearly
to 50% load
Peak (60 seconds) 60W
Relative humidity Non-condensing 5% to 80% RH
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration (See Note 11) 5Hz to 500Hz 2.4G rms peak
OUTPUT SPECIFICATIONS
Output voltage +5V output on triples ±5.0%
adjustability Vout on singles ±5.0%
Line regulation Main output ±0.2%
LL to HL, FL Auxiliary outputs ±1.0%
Load regulation Main output ±2.0%
FL to NL Auxiliary outputs ±5.0%
Transient response +5V (1.5A to 3A) ±120mV max. dev.
500µs recovery
Temperature coefficient All outputs ±0.02%/°C
Overvoltage protection +5V output 125% ±15% Vout
Output power limit Primary power limited 90W input
power limit
Short circuit protection Single outputs Continuous
Multiple outputs Short term
INPUT SPECIFICATIONS
Input voltage range Universal input 85 to 264VAC
120 to 370VDC
Input frequency range 47 to 440Hz
Max. input surge 132VAC, cold start 12A max.
current 264VAC, cold start 24A max.
Safety ground 110VAC, 60Hz 0.13mA max.
leakage current 230VAC, 50Hz 0.32mA max.
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15 Level A
Radiated emissions EN55022 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
SPECIFICATIONS
File Name: nfs40.pdf Rev (02): 21 Apr 2004
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1Natural convection cooled, 40W maximum.
2Peak output current lasting less than 30 seconds with duty cycle less than
10%. During peak loading, outputs may go outside of total regulation
limits. Peak total power must not exceed 60W.
3Forced air, 20 CFM at 1 atmosphere, 50W maximum.
4Figure is peak-to-peak. Output noise is measured across a 50MHz
bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor.
5Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also,
0.25<I(A)/I(B)<5.0 to maintain stated regulation. This does not apply to the
NFS40-7628 power supply as it has regulated auxiliary outputs.
6A minimum load of 0.5A is required on the +5V output to obtain full current
from the negative output.
7The NFS40 offers the possibility of power sharing between outputs.
Consult factory for details.
8Derating curve is application specific for ambient temperatures >50°C, for
optimum reliability no part of the heatsink should exceed 110oC and no
semiconductor case temperature should exceed 115oC.
9A 4W minimum load is recommended to achieve the design MTBF.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four
major resonances.
12 The NFS40-7628 has separately linear regulated +12V and -12V outputs.
The loading conditions in Notes 5 and 6 do not apply.
13 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
NFS40 Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 2
File Name: nfs40.pdf Rev (02): 21 Apr 2004
DERATING CURVE (See Notes 8, 9, 10)
Output Power (Watts)
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
20W
40W
50W
4W
20 CFM FORCED AIR COOLING
25W
NATURAL
CONVECTION
COOLING
4W MIN. LOAD REQUIRED TO ACHIEVE DESIGN MTBF
AC mating connector
Molex 09-50-3031 or equivalent with Molex 08-50-0164 or equivalent crimp
terminals.
DC mating connector
Molex 09-50-3061 or equivalent with Molex 08-50-0164 or equivalent crimp
terminals.
OUTPUT OUTPUT CURRENTS
RIPPLE (4) TOTAL MODEL NUMBER (D)
VOLTAGE MAX (1) PEAK (2) FAN (3) REGULATION (5)
+5.1V (A) 3A 7A 5A 50mV ±2.0% NFS40-7608 (5,6)
+12.0V (B) 2A 3A 2A 120mV ±5.0%
–12.0V (C) 0.35A 1A 0.5A 120mV ±5.0%
+5.1V (A) 4A 7A 5A 50mV ±2.0% NFS40-7628 (12)
+12.0V (B) 0.35A 1A 0.5A 120mV ±5.0%
–12.0V (C) 0.35A 1A 0.5A 120mV ±5.0%
+5.1V (A) 3A 7A 5A 50mV ±2.0% NFS40-7607 (5,6)
+12.0V (B) 2A 3A 2A 120mV ±5.0%
–5.0V (C) 0.35A 1A 0.5A 50mV ±5.0%
+5.1V (A) 3A 7A 5A 50mV ±2.0% NFS40-7610 (5,6)
+15.0V (B) 2A 2.5A 2A 150mV +10%/–3.0%
–15.0V (C) 0.35A 1A 0.5A 150mV ±5.0%
+3.3V 6A 12A 8A 100mV ±2.0% NFS40-76S3
+5.1V 6A 12A 8A 100mV ±2.0% NFS40-7605
+12.0V 3.3A 5A 4A 120mV ±2.0% NFS40-7612
+15.0V 2.6A 4A 3.3A 150mV ±2.0% NFS40-7615
+24.0V 1.6A 2.5A 2A 240mV ±2.0% NFS40-7624
0.156 (3.96) Dia.
(4 Places)
5.00
(127.00)
NON-METALLIC
STAND-OFF
(SEE NOTE A)
MAXIMUM
COMPONENT
HEIGHT 1.2 inches
C5
J2
1
P1 (See Note C)
F1
J1
N
~
L
Q1
F 3.15A, H 250VAC
2.550
(64.8)
0.22
(5.59)
3.00
(76.2)
0.22 (5.59)
4.55
(115.8)
~
ALL DIMENSIONS IN INCHES (mm)
T1
Data Sheet © Artesyn Technologies
®
2004
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NFS40 Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 3
www.artesyn.com
File Name: nfs40.pdf Rev (02): 21 Apr 2004
Mechanical Notes
AIn order to meet safety requirements, a non-metallic stand-off is mandatory
for one hole as specified in the mechanical drawing.
BThe ground pad of the mounting hole near P1 allows system grounding
through a metal stand-off.
CTo improve conducted noise, the ground pad of the mounting hole near the
output connector should be connected with the ground pad of the
mounting hole near P1. Use metal stand-offs attached to a common metal
chassis. This connection also significantly attenuates common mode noise.
DA standard L-bracket and cover is available for mounting which contains all
screws, connectors and necessary mounting hardware. Order part number
‘NFS40 COVER KIT’.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1044
Licence No. 4389, 2559, 1651 and 1044
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
PIN CONNECTIONS
J1 -7608, -7628 -7607 -7610 SINGLES
Pin 1 AC Live AC Live AC Live AC Line
Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral
J2
Pin 1 +12V +12V +15V +Vout
Pin 2 +5.1V +5.1V +5.1V +Vout
Pin 3 +5.1V +5.1V +5.1V +Vout
Pin 4 Return Return Return Return
Pin 5 Return Return Return Return
Pin 6 –12V –5V –15V Return
P1(C)
Pin 1 Safety Ground