INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R06
CPC1963
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameter Ratings Units
Blocking Voltage 600 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1150 mW
Total Package Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Operating Voltage Range VT- 20 - 260 Vrms
Load Current, Continuous VL=120Vrms IL0.005 - 0.5 Arms
Off State Leakage Current V = 600V ILEAK --1mA
On-State Voltage Drop IL=500 mArms VON - - 1.4 Vrms
Critical Rate of Rise 3- dV/dt 1000 - - V/µs
Switching Speeds
Turn-on IF=5 mA ton - - 0.5 cycles
Turn-off toff - - 0.5
Zero-Cross Turn-On Voltage 11st half-cycle - 2 10 V
Subsequent half-cycle - - 1 -
Operating Frequency - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On 2- PF 0.25 - - -
Input Characteristics
Input Control Current to Activate 4-I
F- 0.23 5 mA
Input Drop-out Voltage - 0.8 - - V
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3-pF
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments use at least 10mA LED current.