Additional Resources: Product Page | 3D Model date 01/03/2020 page 1 of 4 MODEL: CPT-3526-L100 DESCRIPTION: PIEZO ELEMENT FEATURES * 100 mm lead wire * piezo element * externally driven SPECIFICATIONS parameter conditions/description min typ max units 30 Vp-p 2,100 2,600 3,100 Hz 300 21,000 30,000 39,000 pF operating voltage resonant frequency resonant impedance electrostatic capacitance at 120 Hz dimensions O35 x 0.53 mm weight 4.0 material brass terminal wire leads g operating temperature -20 60 C storage temperature -20 70 C RoHS Notes: yes 1. All specifications measured at 253C, humidity at 60~70%, under 86~106 kPa pressure, unless otherwise noted. SOLDERABILITY parameter conditions/description min typ max units hand soldering for 3 seconds 370 380 390 C cuidevices.com Additional Resources: Product Page CUI Devices MODEL: CPT-3526-L100 DESCRIPTION: PIEZO ELEMENT | 3D Model date 01/03/2020 page 2 of 4 MECHANICAL DRAWING units: mm tolerance: 0.5 mm wire: UL 1571 32 AWG *OXH$ APPLICATION CIRCUIT Vout- Vin Vout+ cuidevices.com Additional Resources: Product Page CUI Devices MODEL: CPT-3526-L100 DESCRIPTION: PIEZO ELEMENT PACKAGING units: mm Carton Size: 315 x 310 x 300 mm Carton QTY: 5,000 pcs per carton 3&6EDJ cuidevices.com | 3D Model date 01/03/2020 page 3 of 4 Additional Resources: Product Page CUI Devices MODEL: CPT-3526-L100 DESCRIPTION: PIEZO ELEMENT | 3D Model date 01/03/2020 page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 07/15/2019 1.01 updated packaging details 09/10/2019 1.02 brand update 01/03/2020 The revision history provided is for informational purposes only and is believed to be accurate. CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. cuidevices.com