Stock Mfr.Õs Description
No. Type
921-3575 SLD-12-1818-12T* 12 V @ 1.8 A* Ð12 V @ 1.8 A* 7.00 ´4.87 ´2.95 82.00
921-9380 SLD-12-3434-12T 12 V @ 3.4 A Ð12 V @ 3.4 A 9.00 ´4.87 ´3.30 113.49
921-9396 SLD-15-3030-15T 15 V @ 3 A Ð15 V @ 3 A 9.00 ´4.87 ´3.30 105.00
921-9406 SLD-12-3015-05T 5 V @ 3 A 12 V @ 1.5 A 7.00 ´4.87 ´2.95 85.38
921-9415 SLT-12-31010-12T 5 V @ 3 A 12 V @ 1 A* Ð12 V @ 1 A* 10.25 ´4.00 ´2.95 88.91
921-9420 SLT-12-61010-12T 5 V @ 6 A 12 V @ 1 A* Ð12 V @ 1 A* 9.00 ´4.87 ´3.30 111.00
921-9425 SLT-12-61818-12T 5 V @ 6 A 12 V @ 1.8 A* Ð12 V @ 1.8 A* 11.00 ´4.87 ´3.30 118.00
921-9430 SLT-24-30530-05T 5 V @ 3 A Ð5 V @ .5 A Ð24 V @ 3 A 11.00 ´4.87 ´3.30 135.00
Overvoltage Protectors (OVP)
921-9435 SLO-12-000-1 6.2 V to 34 V 1.50 ´1.55 ´0.56 11.11
*Adjustable to 15 volts. Adjustable @ 15 A.
New Cover Options
c
Covers Are Sold Separately
c
When Covers Are Used, Derate the Power Supply by 10% of Its Rated Value
Single Output Series Power Supplies
Features and Benefits
c
Easy to Screw Terminals
c
Tight Regulation: 0.10% Line and Load Combined
c
No Soldering Required
c
Terminal Block Connection
c
Built-In OVP on 5 V Models (Optional on 12 V, 15 V,
24 V)
c
Foldback Current Limiting
c
Form, Fit, Function Replacements for Most Major
Manufacturers
Features and Benefits (Continued)
c
UL Recognized, CSA and TV Certified, CE Approval
c
Input Voltage: 100/120/220/230/240 AC
c
Input Frequency: 47-63 Hz
c
100% Four Hours Burn-In
c
Remote Sensing
c
Operating Temperature: 0¡ to +50¡C
c
EMI/RFI Meets FCC Class B and VDE 0871 for
Class B
c
Shock Vibration Per Mil-STD-810C
Copperline supplies can be used in either a constant voltage or constant current mode. The Copperline offers such
features as a single supply to be used in applications where separate supplies are required for each output voltage. Three
phase operation for high current, low ripple operation may be achieved by connecting three Copperline power supplies to
three different phases and connecting the power supply outputs in parallels. Large filter capacitors provide low noise
operation over a wide line range. Panel mounted voltage control provided AC.
Specifications
Input
Input Voltage: 105-130/210-260 VAC (user selectable). Input Frequency: 47-63 Hz. Input Protection: Ext. slow-blow fuse required.
Output
Line Regulation: 0.1% or 50 mV. Load Regulation: 0.1% or 50 mV. Output Ripple @ Full Rated Load: 1.0% or 50 mV RMS max.
Controls
Current Limit Adjust: 0-100%. Output Volt Adjust: 10-100% coarse adjust (may be mounted remotely). Fine adjust fine
tunes output for no load and full load conditions.
General
Operating Temp. @ Full Rated Load: 0 to 50¡C. Storage Temp.: Ð20 to 70¡C. Efficiency @ Full Rated Load: 75%.
Vibration: Designed to meet MIL-STD-810D, Method 514.3, Category 1, Procedure 1. Shock: Designed to meet
MIL-STD-810D, Method 516.3, Procedure III.
921-9801 SLCASA-CVR Cover for SLS-05-030-1; -12-017; -24-012 25.43
921-9802 SLCASB-CVR Cover for SLS-05-060-1; -12-034; or -24-024 20.00
921-9803 SLCASC-CVR Cover for SLS-05-090-1; -12-057; or -15-045 20.00
921-9804 SLCASD-CVR Cover for SLD-12-1818-12; -24-036; or -12-3015-05 20.00
921-9810 SLCASG-CVR Cover for SLT-12-61818-12T, 24-305, 30-05T 31.38
921-9809 SLCASH-CVR Cover for SLD-12-1010-12; -24-048; or -12-20404 17.00
921-9808 SL-CASI-CVR Cover for SLS-05-120-1; -12-068; -15-060 20.00
921-9811 SLCASK-CVR Cover for SLS-24-072T 47.00
921-9812 SLCASL-CVR Cover for SLS-24-120T 31.38
EACH
1-4
Sola/Hevi-Duty
Stock Mfr.Õs Output Output Output Dimensions
No. Type 1 2 3 (In.)
921-9301 SLS-05-030-1T 5 V @ 3.0 A 4.83 ´3.99 ´2.07 45.00
921-9456 SLS-05-060-1T 5 V @ 6.0 A 4.87 ´5.62 ´2.95 74.03
921-9461 SLS-05-090-1T 5 V @ 9.0 A 7.00 ´4.87 ´3.30 114.92
921-9316 SLS-05-120-1T 5 V @ 12.0 A 9.00 ´4.87 ´3.30 132.60
921-9321 SLS-12-017T 12 V @ 1.7 A* 4.83 ´3.99 ´2.07 48.65
921-9326 SLS-12-034T 12 V @ 3.4 A 5.62 ´4.87 ´2.95 63.26
921-9331 SLS-12-051T 12 V @ 5.1 A 7.00 ´4.87 ´3.30 88.89
921-9336 SLS-12-068T 12 V @ 6.8 A 9.00 ´4.87 ´3.30 114.92
921-9346 SLS-15-045T 15 V @ 4.5 A 7.00 ´4.87 ´3.30 103.70
921-9347 SLS-15-060T 15 V @ 6.0 A 9.00 ´4.87 ´3.30 115.60
921-9348 SLS-24-012T 24 V @ 1.2 A 4.83 ´3.99 ´2.07 49.30
921-9350 SLS-24-024T 24 V @ 2.4 A 5.62 ´4.87 ´2.95 60.94
921-9351 SLS-24-036T 24 V @ 3.6 A 7.00 ´4.87 ´3.30 102.77
921-9352 SLS-24-048T 24 V @ 4.8 A 9.00 ´4.87 ´3.30 137.02
921-9353 SLS-24-072T 24 V @ 7.2 A 4.88 ´13.87 ´3.53 137.00
921-9354 SLS-24-120T 24 V @ 12.0 A 4.88 ´16.85 ´5.00 189.72
SOLA Linear and High Power Adjustable Supplies
Turn To Section 1 For Allied Office Addresses and Local Phone Numbers ALLIED
c
711
Copper-Line High Power Adjustable DC Power Supply
Stock Mfr.Õs Power
No. Type (Watts)
Dimensions (In.)
Wt. 1-2Length Width* HeightVolts Amps
EACH
921-9407 39-407 300 5-50/2-25 6/12 11.00 6.75 7.66 23 615.64
921-9408 39-408 600 5-50/2-25 12/24 12.00 6.75 7.66 30 768.72
921-9409 39-409 1200 5-50/2-25 24/48 14.00 10.00 11.12 73 1385.21
*Includes capacitor.
DC Output
Stock Mfr.Õs Dimensions
Output
No. Type (In.)
EACH
1-4
EACH
1-4
Regulated Linear Single Output
c
Convection Cooled
c
Complete Serviceability
c
Constant Voltage
c
Overvoltage Protection Available
921-6400 81-05-230-2 104-127 VAC 5 3.0 1 67.00 61.20
921-9910 81-12-215-2 104-127 VAC 12-15 1.5-1.2 1 67.00 61.20
921-9421 81-24-180-2 104-127 VAC 24 0.8 1 63.00 60.18
921-9930 83-05-230-3 208-254 VAC 5 3.0 3 63.00 61.48
921-6445 83-12-218-3 208-254 VAC 12 1.8 3 74.00 70.38
921-6450 83-15-216-3 208-254 VAC 15 1.6 3 74.00 69.05
921-6465 83-24-212-3 208-254 VAC 24 1.2 3 64.00 61.50
921-4851 83-05-260-3 208-254 VAC 5 6.0 2 153.00 141.23
921-6511 83-12-250-3 208-254 VAC 12 5.0 2 153.00 144.84
921-8004 83-15-240-3 208-254 VAC 15 4.0 2 153.00 144.84
921-4853 83-24-225-3 208-254 VAC 24 2.5 2 130.74 125.02
921-8006 83-12-310-3 208-254 VAC 12 10.0 4 216.00 208.08
921-8021 83-24-260-3 208-254 VAC 24 6.0 4 196.00 189.00
Stock Mfr.Õs Input
No. Type Voltage
DC Output
Volts Amps
Chassis
Style
EACH
1-4 5-9
Low cost DC power supplies give you a precise integrated circuit regulator with superior drift characteristics. Features
short circuit protection, automatic foldback current limiting, automatic reset, and isolated, floating output. Low noise and
ripple (pard). Designed for both bench and rack use.
Specifications
Input
Input Voltage: Limit Ñ (81 Series) 104-127 VAC, (83 Series) 208-254 VAC. Input Frequency: Limit Ñ 50-60 Hz.
Output
Source and Load Effect Combined: Condition Ñ Regulation Line and Load; Limit Ñ ±0.1%. Pard (Ripple and Noise):
Limit Ñ 0.1% pk/pk. Periodic Deviations (ripple): Limit Ñ 10 mv RMS. Output Voltage Adjustment: Limit Ñ ±5%
Minimum. Overvoltage Protection: Limit Ñ Available for all models as an option. Provides both transient and power
supply malfunction protection. Transient Recovery Time: Condition Ñ (
1
/
2
L to FL.); Limit Ñ Less than 20 µ Sec.
General
Storage Ambient Temp.: Limit Ñ Ð40¡C to +85¡C. Operating Ambient Temp.: Limit Ñ0¡C to +55¡C. Temp. Effect
Coefficient: Limit Ñ 0.03%¡C. Polarity: Limit Ñ May be used positive or negative. Short Circuit Protection: Limit Ñ
Protected with automatic recovery. Max. Allowable Lead Drop For Remote Sensing: Limit Ñ 5%. Max. Output Current:
Limit Ñ 120% rated current. Max. Short Circuit Current: Limit Ñ 30% rated current. Input/Output Isolation: Limit Ñ
1000 Megohms D.C., 2500 VAC. Specifications are typical, contact factory for more information.
Features
c
Universal 120/240 VAC, 50/60 Hz Input
c
Single Supply for Multiple Applications
c
Parallel Operation for Increased Power Output
c
UL Recognized, CSA Certified
c
Reliable SCR Design
Features (Continued)
c
Warranted for One Full Year
c
Adjustable Voltage From 2 to 50 Volts
c
Can Be Paralleled for More Power
c
Adjustable Constant Current From 0 to 100%
Applications
c
Engineering Bench Supply
c
Slot Power Supply
c
Telecommunications
c
Manufacturing Test Applicators
Applications (Continued)
c
Automotive Product Testing
c
DC Motor Drives
c
Relay and Solenoid Drives
SOLA Silver Line Linears,International Series
Triple Output Series Power Supplies
12