LTC4100 Smart Battery Charger Controller Features n n n n n n n n n n n n n n n Description Single Chip Smart Battery Charger Controller 100% Compliant (Rev. 1.1) SMBus Support Allows for Operation with or without Host SMBus Accelerator Improves SMBus Timing Wide Output Voltage Range: 3.5V to 26V Hardware Interrupt and SMBAlert Response Eliminate Interrupt Polling High Efficiency Synchronous Buck Charger 0.5V Dropout Voltage; Maximum Duty Cycle > 98% AC Adapter Current Limit Maximizes Charge Rate 0.8% Voltage Accuracy; 4% Current Accuracy Up to 4A Charging Current Capability 10-Bit DAC for Charge Current Programming 11-Bit DAC for Charger Voltage Programming User-Selectable Overvoltage and Overcurrent Limits High Noise Immunity SafetySignal Sensor Available in a 24-Pin SSOP Package The LTC(R)4100 Smart Battery Charger is a single chip charging solution that dramatically simplifies construction of an SBS compliant system. The LTC4100 implements a Level 2 charger function whereby the charger can be programmed by the battery or by the host. A SafetySignal on the battery being charged is monitored for temperature, connectivity and battery type information. The SMBus interface remains alive when the AC power adapter is removed and responds to all SMBus activity directed to it, including SafetySignal status (via the ChargerStatus command). The charger also provides an interrupt to the host whenever a status change is detected (e.g., battery removal, AC adapter connection). Charging current and voltage are restricted to chemistryspecific limits for improved system safety and reliability. Limits are programmable by two external resistors. Additionally, the maximum average current from the AC adapter is programmable to avoid overloading the adapter when simultaneously supplying load current and charging current. When supplying system load current, charging current is automatically reduced to prevent adapter overload. Applications n n Portable Instruments and Computers Data Storage Systems and Battery Backup Servers L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks and PowerPath is a trademark of Linear Technology Corporation. All other trademarks are the property of their respective owners. Protected by U.S. Patents including 6650174 and 5723970. Typical Application DCIN 3V TO 5.5V 1.21k 17 11 6 CHGEN 10 ACP 7 9 8 15 16 13 1.13k 14 10k 54.9k SMBALERT# 0.1F 13.7k 20 LTC4100 VDD DCIN DCDIV INFET CHGEN CLP ACP CLN SMBALERT TGATE SCL BGATE SDA PGND THB CSP THA BAT ILIM VSET VLIM ITH IDC GND 0.068F 0.1F 5 4 0.033 VBAT PART < 5.5V > 5.5V LTC4101 LTC4100 5k 24 23 SYSTEM LOAD 20F 1 3 SMART BATTERY 0.025 10H 2 20F 21 22 18 19 12 0.01F 6.04k 100 0.0015F 0.12F 0.1F SafetySignal SMBCLK SMBCLK SMBDAT SMBDAT Figure 1. 4A Smart Battery Charger For more information www.linear.com/LTC4100 4100 TA01 4100fc 1 LTC4100 Absolute Maximum Ratings Pin Configuration (Note 1) TOP VIEW Voltage from VDD to GND.................................. 7V/-0.3V Voltage from CHGEN, DCDIV, SDA, SCL and SMBALERT to GND............................. 7V/-0.3V Voltage from DCIN, CLP, CLN to GND............. 32V/-0.3V Voltage from CLP to CLN........................................0.3V PGND wrt. GND..................................................... 0.3V CSP, BAT to GND................................................ 28V/-5V Operating Ambient Temperature Range (Note 4) - 40C to 85C Junction Temperature Range................. -40C to 125C Storage Temperature Range................... -65C to 150C Lead Temperature (Soldering, 10 sec).................... 300C TGATE 1 24 CLP PGND 2 23 CLN BGATE 3 22 BAT INFET 4 21 CSP DCIN 5 20 IDC CHGEN 6 19 ITH SMBALERT 7 18 VSET SDA 8 17 VDD SCL 9 16 THA ACP 10 15 THB DCDIV 11 14 VLIM GND 12 13 ILIM G PACKAGE 24-LEAD PLASTIC SSOP TJMAX = 125C, JA = 90C/W Order Information LEAD FREE FINISH TAPE AND REEL PART MARKING PACKAGE DESCRIPTION TEMPERATURE RANGE LTC4100EG#PBF LTC4100EG#TRPBF LTC4100EG 24-Lead Plastic SSOP -40C to 85C LEAD BASED FINISH TAPE AND REEL PART MARKING PACKAGE DESCRIPTION TEMPERATURE RANGE LTC4100EG LTC4100EG#TR LTC4100EG 24-Lead Plastic SSOP -40C to 85C Consult LTC Marketing for parts specified with wider operating temperature ranges. For more information on lead free part marking, go to: http://www.linear.com/leadfree/ For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/ Electrical Characteristics The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VDCIN = 20V, VDD = 3.3V, VBAT = 12V unless otherwise noted. (Note 4) SYMBOL PARAMETER CONDITIONS DCIN Operating Range MIN IDCIN DCIN Operating Current Charging, Sum of Currents on DCIN, CLP and CLN VTOL Charge Voltage Accuracy (Note 2) ITOL Charge Current Accuracy (Note 3) VDD TYP 6 3 MAX UNITS 28 V 5 mA -0.8 -1 0.8 1 % % VCSP - VBAT Target = 102.3mV IDAC = 0xFFFF -4 -5 4 5 % % VDD Operating Voltage 0V VDCIN 28V 3 5.5 V Battery Leakage Current DCIN = 0V, VCLP = VCLN = VCSP = VBAT 15 35 A Undervoltage Lockout Threshold DCIN Rising, VBAT = 0V 4.7 5.5 V VDD Power-Fail Part Held in Reset Until this VDD Present DCIN Current in Shutdown VCHGEN = 0V Shutdown UVLO 2 4.2 2 3 V 3 mA 4100fc For more information www.linear.com/LTC4100 LTC4100 Electrical Characteristics The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VDCIN = 20V, VDD = 3.3V, VBAT = 12V unless otherwise noted. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS Current Sense Amplifier, CA1 Input Bias Current into BAT Pin CMSL CA1/I1 Input Common Mode Low CMSH CA1/I1 Input Common Mode High 11.66 VDCIN 28V A 0 V VCLN -0.2 V Current Comparators ICMP and IREV ITMAX Maximum Current Sense Threshold (VCSP -VBAT) VITH = 2.5V ITREV Reverse Current Threshold (VCSP -VBAT) 140 165 200 - 30 mV mV Current Sense Amplifier, CA2 Transconductance 1 mmho Source Current Measured at ITH, VITH = 1.4V -40 A Sink Current Measured at ITH, VITH = 1.4V 40 A Current Limit Amplifier Transconductance VCLP Current Limit Threshold ICLN CLN Input Bias Current 1.5 93 100 mmho 107 100 mV nA Voltage Error Amplifier, EA Transconductance 1 Measured at ITH, VITH = 1.4V Sink Current OVSD Overvoltage Shutdown Threshold as a Percent of Programmed Charger Voltage mmho 36 A 102 107 110 % 0 0.17 0.25 V 25 50 Input P-Channel FET Driver (INFET) DCIN Detection Threshold (VDCIN -VCLP) DCIN Voltage Ramping Up from VCLP -0.05V Forward Regulation Voltage (VDCIN -VCLP) Reverse Voltage Turn-Off Voltage (VDCIN -VCLP) -60 -25 5 5.8 INFET ON Clamping Voltage (VDCIN -VINFET) IINFET = 1A INFET OFF Clamping Voltage (VDCIN -VINFET) IINFET = -25A mV mV 6.5 V 0.25 V 345 kHz Oscillator fOSC Regulator Switching Frequency 255 300 fMIN Regulator Switching Frequency in Drop Out Duty Cycle 98% 20 25 kHz DCMAX Regulator Maximum Duty Cycle VCSP = VBAT 98 99 % Gate Drivers (TGATE, BGATE) VTGATE High (VCLP-VTGATE) ITGATE = -1mA 50 mV VBGATE High CLOAD = 3000pF 4.5 VTGATE Low (VCLP-VTGATE) CLOAD = 3000pF 4.5 5.6 10 V 5.6 10 V VBGATE Low IBGATE = 1mA 50 mV TGTR TGTF TGATE Transition Time TGATE Rise Time TGATE Fall Time CLOAD = 3000pF, 10% to 90% CLOAD = 3000pF, 10% to 90% 50 50 110 100 ns ns BGTR BGTF BGATE Transition Time BGATE Rise Time BGATE Fall Time CLOAD = 3000pF, 10% to 90% CLOAD = 3000pF, 10% to 90% 40 40 90 80 ns ns VTGATE at Shutdown (VCLN-VTGATE) ITGATE = -1A 100 mV VBGATE at Shutdown ITGATE = 1A 100 mV 4100fc For more information www.linear.com/LTC4100 3 LTC4100 Electrical Characteristics The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VDCIN = 20V, VDD = 3.3V, VBAT = 12V unless otherwise noted. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX 1.14 1.20 1.26 UNITS AC Present Comparator VACP DCDIV Threshold VDCDIV Rising from 1V to 1.4V DCDIV Hysteresis 25 DCDIV Input Bias Current VDCDIV = 1.2V -1 ACP VOH IACP = -2mA 2 ACP VOL DCDIV to ACP Delay V mV 1 A IACP = 1mA 0.5 V VDCDIV = 1.3V 10 s V SafetySignal Decoder SafetySignal Trip (RES_COLD/RES_OR) RTHA = 1130 1%, CTH = 1nF (Note 6) RTHB = 54.9k 1% 95 100 105 k SafetySignal Trip (RES_IDEAL/RES_COLD) RTHA = 1130 1%, CTH = 1nF (Note 6) RTHB = 54.9k 1% 28.5 30 31.5 k SafetySignal Trip (RES_HOT/RES_IDEAL) RTHA = 1130 1%, CTH = 1nF (Note 6) RTHB = 54.9k 1% 2.85 3 3.15 k SafetySignal Trip (RES_UR/RES_HOT) RTHA = 1130 1%, CTH = 1nF (Note 6) RTHB = 54.9k 1% 425 500 575 Time Between SafetySignal Measurements DCDIV = 1.3V DCDIV = 1V 250 ms ms Charging Current Resolution Guaranteed Monotonic Above IMAX/16 Charging Current Granularity RILIM = 0 RILIM = 10k 1% RILIM = 33k 1% RILIM = Open (or Short to VDD) Wake-Up Charging Current (IWAKE-UP) All Values of RILIM All Values of RVLIM Charging Current Limit CSP - BAT RILIM = 0 (0-1A) Charging Current = 0x03FF (0x0400 Note 7) 97.3 107.3 mV RILIM = 10k 1% (0-2A) Charging Current = 0x07FE (0x0800 Note 7) 97.3 107.3 mV RILIM = 33k 1% (0-3A) Charging Current = 0x0BFC (0x0C00 Note 7) 72.3 82.3 mV RILIM = 0pen (or Short to VDD) (0-4A) Charging Current = 0x0FFC (0x1000 Note 7) 97.3 107.3 mV Guaranteed Monotonic (2.9V VBAT 28V) 11 32 DACs Charging Voltage Resolution 10 1 2 4 4 4 mA mA mA mA 80 (Note 5) Charging Voltage Granularity Charging Voltage Limit Bits mA Bits 16 mV RVLIM = 0 Charging Voltage = 0x2260 (Note 7) 8.730 8.800 8.870 V RVLIM = 10k 1% Charging Voltage = 0x3330 (Note 7) 12.999 13.104 13.209 V RVLIM = 33k 1% Charging Voltage = 0x4400 (Note 7) 17.269 17.408 17.547 V RVLIM = 100k 1% Charging Voltage = 0x5400 DCIN 22V (Note 7) 21.538 21.712 21.886 V RVLIM = 0pen (or Short to VDD) Charging Voltage = 0x6D60 DCIN 29V (Note 7) 27.781 28.006 28.231 V 4100fc For more information www.linear.com/LTC4100 LTC4100 Electrical Characteristics The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VDCIN = 20V, VDD = 3.3V, VBAT = 12V unless otherwise noted. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS Logic Levels VIL SCL/SDA Input Low Voltage VDD = 3V and VDD = 5.5V VIH SCL/SDA Input High Voltage VDD = 3V and VDD = 5.5V 0.8 2.1 V V VOL SDA Output Low Voltage IPULL-UP = 350A 0.4 V IIL SCL/SDA Input Current VSDA, VSCL = VIL -1 1 A IIH SCL/SDA Input Current VSDA, VSCL = VIH -1 1 A VOL SMBALERT Output Low Voltage IPULL-UP = 500A SMBALERT Output Pull-Up Current VSMBALERT = VOL ILEAK SDA/SCL/SMBALERT Power Down Leakage VSDA, VSCL, VSMBALERT = 5.5V, VDD = OV VOL CHGEN Output Low Voltage IOL = 100A CHGEN Output Pull-Up Current VCHGEN = VOL -17.5 -2 -17.5 VIL CHGEN Input Low Voltage VIH CHGEN Input High Voltage VDD = 3V VDD = 5.5V Power-On Reset Duration VDD Ramp from 0V to >3V in <5s -10 -10 2.5 0.4 V -3.5 A 2 A 0.5 V -3.5 A 0.9 V 3.9 V V 100 s SMBus Timing (Refer to System Management Bus Specification, Revision 1.1, Section 2.1 for Timing Diagrams) tHIGH SCL Serial Clock High Period IPULL-UP = 350A, CLOAD = 250pF, RPU = 9.31k, VDD = 3V and VDD = 5.5V 4 tLOW SCL Serial Clock Low Period IPULL-UP = 350A, CLOAD = 250pF, RPU = 9.31k, VDD = 3V and VDD = 5.5V 4.7 tR SDA/SCL Rise Time CLOAD = 250pF, RPU = 9.31k, VDD = 3V and VDD = 5.5V tF SDA/SCL Fall Time tSU:STA s 15000 s 1000 ns CLOAD = 250pF, RPU = 9.31k, VDD = 3V and VDD = 5.5V 300 ns Start Condition Setup Time VDD = 3V and VDD = 5.5V 4.7 s tHD:STA Start Condition Hold Time VDD = 3V and VDD = 5.5V 4 s tHD:DAT SDA to SCL Falling-Edge Hold Time, Slave Clocking in Data VDD = 3V and VDD = 5.5V 300 ns tTIMEOUT Time Between Receiving Valid ChargingCurrent() VDD = 3V and VDD = 5.5V and ChargingVoltage() Commands 140 Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: See Test Circuit. Note 3: Does not include tolerance of current sense resistor. Note 4: The LTC4100E is guaranteed to meet performance specifications from 0C to 70C. Specifications over the -40C to 85C operating temperature range are assured by design, characterization and correlation with statistical process controls. 175 210 sec Note 5: Current accuracy dependent upon circuit compensation and sense resistor. Note 6: CTH is defined as the sum of capacitance on THA, THB and SafetySignal. Note 7: The corresponding overrange bit will be set when a HEX value greater than or equal to this value is used. 4100fc For more information www.linear.com/LTC4100 5 LTC4100 Typical Performance Characteristics INFET Response Time to Reverse Current 0 Vgs OF PFET (2V/DIV) Vs = 0V Id (REVERSE) OF PFET (5A/DIV) Id = 0A 300 -1.0 PWM FREQUENCY (kHz) Vs OF PFET (5V/DIV) -1.5 -2.0 -2.5 -3.0 -3.5 -4.0 TEST PERFORMED ON DEMOBOARD VCHARGE = 12.6V VIN = 15VDC CHARGER = ON INFET = 1/2 Si4925DY ICHARGE = <10mA 4100 G01 1A STEP 3A STEP RECONNECT 100 VDCIN = 0V 20 15 10 90 85 80 0 5 10 15 20 BATTERY VOLTAGE (V) 25 75 30 0.50 SMBus Accelerator Operation Low Current Operation 0.5 VDD = 5V TEMP = 27C 0.4 DCIN = 15V LTC4100 85 RPULLUP = 15k 0V 0.3 NO LOW CURRENT MODE 0.2 LOW CURRENT MODE 0.1 0 1.00 1.50 2.00 2.50 CHARGING CURRENT (A) 3.00 4100 G06 VDD = 5V 5V CBUS = 200pF TA = 25C 0.50 1.00 1.50 2.00 2.50 CHARGING CURRENT (A) 4100 G05 MEASURED CURRENT (A) EFFICIENCY (%) 16.8V 5 Efficiency at 12.6V with 15V VDCIN -0.1 3.00 1s/DIV 4100 G07 6 Efficiency at 19V VDCIN 12.6V 25 90 75 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 DUTY CYCLE (VOUT/VIN) 95 4100 G04 80 0 4100 G03 30 0 95 DCIN = 15V DCIN = 20V DCIN = 24V 35 LOAD CURRENT = 1A, 2A, 3A DCIN = 20V VFLOAT = 12.6V 100 PROGRAMMED CURRENT = 10% 100 0 EFFICIENCY (%) BATTERY LEAKAGE CURRENT (A) 3A STEP DISCONNECT 150 Battery Leakage Current vs Battery Voltage 40 LOAD STATE 200 4100 G02 Disconnect/Reconnect Battery (Load Dump) VFLOAT 1V/(DIV) 250 50 -4.5 DCIN = 20V VBAT = 12.6V -5.0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 OUTPUT CURRENT (A) 1.25s/DIV 1A STEP PWM Frequency vs Duty Cycle 350 -0.5 OUTPUT VOLTAGE ERROR (%) Vgs = 0 VOUT vs IOUT 4100 G08 0 PROGRAMMED CURRENT 0.2 0.1 0.3 PROGRAMMED CURRENT (A) 0.4 4100 G09 4100fc For more information www.linear.com/LTC4100 LTC4100 Typical Performance Characteristics Charging Current Error 0.4 OUTPUT VOLTAGE ERROR (V) VDD = 5V TEMP = 27C VLOAD = 12V 0.3 OUTPUT CURRENT ERROR (A) Charging Voltage Error 0.150 0.2 0.1 0 -0.1 -0.2 DCIN = 15V, NoLowI DCIN = 20V, NoLowI DCIN = 15V, LowI DCIN = 20V, LowI -0.3 -0.4 0 2 1 3 CHARGING CURRENT (A) VDD = 5V 0.125 TEMP = 27C 0.100 ILOAD = 0.120A 0.075 0.050 DCIN = 20V 0.025 DCIN = 15V 0 -0.025 -0.050 -0.075 -0.100 -0.125 4 -0.150 0 2 4 4100 G10 6 8 10 12 14 16 18 20 22 CHARGING VOLTAGE (V) 4100 G11 Pin Functions TGATE (Pin 1): Drives the Top External P-MOSFET of the Battery Charger Buck Converter. PGND (Pin 2): High Current Ground Return for BGATE Driver. BGATE (Pin 3): Drives the Bottom External N-MOSFET of the Battery Charger Buck Converter. INFET (Pin 4): Drives the Gate of the External Input P-MOSFET. DCIN (Pin 5): External DC Power Source Input. Bypass to ground with a 0.1F capacitor. CHGEN (Pin 6): Digital Bidirectional Pin to Enable Charger Function. This pin is connected as a wired AND bus. The following events will cause the POWER_FAIL bit in the ChargerStatus register to become set: 1. An external device pulling the CHGEN signal to within 0.9V to GND; 2. The AC adapter voltage is not above the battery voltage. SMBALERT (Pin 7): Active Low Interrupt Output to Host (referred to as the SMBALERT# signal in the SMBus Revision 1.1 specification). Signals host that there has been a change of status in the charger registers and that the host should read the LTC4100 status registers to determine if any action on its part is required. This signal can be connected to the optional SMBALERT# line of the SMBus. Open drain with weak current source pull-up to VDD (with Schottky to allow it to be pulled to 5V externally). SDA (Pin 8): SMBus Data Signal from Main (hostcontrolled) SMBus. External pull-up resistor is required. SCL (Pin 9): SMBus Clock Signal from Main (hostcontrolled) SMBus. External pull-up resistor is required. ACP (Pin 10): This Output Indicates the Value of the DCDIV Comparator. It can be used to indicate whether AC is present or not. DCDIV (Pin 11): Supply Divider Input. This is a high impedance comparator input with a 1.2V threshold (rising edge) and hysteresis. GND (Pin 12): Ground for Digital and Analog Circuitry. ILIM (Pin 13): An external resistor is connected between this pin and GND. The value of the external resistor programs the range and resolution of the programmed charger current. This is a digital, not an analog, function. 4100fc For more information www.linear.com/LTC4100 7 LTC4100 Pin Functions VLIM (Pin 14): An external resistor is connected between this pin and GND. The value of the external resistor programs the range and resolution of the charging voltage. This is a digital, not an analog, function. THB (Pin 15): SafetySignal Force/Sense Pin to Smart Battery. See description of operation for more detail. The maximum allowed combined capacitance on THA, THB and SafetySignal is 1nF (see Figure 4). A series resistor 54.9k needs to be connected between this pin and the battery's SafetySignal for this circuit to work correctly. THA (Pin 16): SafetySignal Force/Sense Pin to Smart Battery. See description of operation for more detail. The maximum allowed combined capacitance on THA, THB and SafetySignal is 1nF (see Figure 4). A series resistor 1130 needs to be connected between this pin and the battery's SafetySignal for this circuit to work correctly. VDD (Pin 17): Power Supply Input for the LTC4100 Digital Circuitry. Bypass this pin with 0.1F. Typically between 3.3V and 5VDC. VSET (Pin 18): Tap Point of the Programmable Resistor Divider, which Provides Battery Voltage Feedback to the Charger. 8 ITH (Pin 19): Control Signal of the Inner Loop of the Current Mode PWM. Higher ITH corresponds to higher charging current in normal operation. A 0.0015F capacitor to GND filters out PWM ripple. Typical full-scale output current is 40A. Nominal voltage range for this pin is 0V to 3V. IDC (Pin 20): Bypass to GND with a 0.068F Capacitor. CSP (Pin 21): Current Amplifier CA1 Input. This pin and the BAT pin measure the voltage across the sense resistor, RSENSE, to provide the instantaneous current signals required for both peak and average current mode operation. BAT (Pin 22): Battery Sense Input and the Negative Reference for the Current Sense Resistor. A bypass capacitor of at least 10F is required. CLN (Pin 23): Negative Input to the Input Current Limiting Circuit Block. If no current limit function is desired, connect this pin to CLP. The threshold is set at 100mV below the voltage at the CLP pin. When used to limit supply current, a filter is needed to filter out the switching noise. CLP (Pin 24): Positive Input to the Input Current Limiting Circuit Block. This pin also serves as a power supply for the IC. 4100fc For more information www.linear.com/LTC4100 LTC4100 Block Diagram VBAT VSET 18 C5, 0.1F GND 11-BIT VDAC 12 DCIN SYSTEM LOAD 20F 3k + 11.67A 3k 0V - 1.19V + gm = 1m EA D1 Q3 BGATE PGND R1 RCL TGATE C9 CLN CLP DCIN INFET Q1 VIN 1 2 - IREV 17mV + 100mV + CL1 - 23 24 gm = 1.5m gm = 1m 20 - CA2 + 1.19V 19 5.8V 4 C1, 0.1F ITH CLP VDD C7 0.0015F R5, 6.04k C6, 0.12F R11 1.2V R10 VIN 10A TO HOST AND BATTERY SDA 8 17 VDD TO SMBUS POWER SUPPLY SMBus INTERFACE AND CONTROL LIMIT DECODER SCL 9 THA 54.9k C8 0.068F 10 ACP DCDIV 11 SMBALERT 7 1.13k IDC 10-BIT IDAC 5 CHGEN 6 CSP ICMP PWM LOGIC 3 20F CSP + - S Q R Q2 21 BUFFERED ITH /5 CSP 22 9k CLP L1 VBAT BAT RSENSE 1.28V OSCILLATOR WATCHDOG DETECT tON - - CA1 + C4 0.01F R4 100 THB 16 15 THERMISTER INTERFACE 13 14 ILIM VLIM RVLIM RILIM 10k Figure 2 4100fc For more information www.linear.com/LTC4100 9 LTC4100 Test Circuit LTC4100 - + 21 CSP + EA VTOL = VDAC 22 18 BAT VSET DCIN = 21V ITH LT1055 VBAT - VVDAC * 100 VVDAC FOR VVDAC = 17.57V(0x44A0) 19 CLN = CLP = 20V + - 1.19V 0.6V - 4100 TC01 Operation Overview (Refer to Block Diagram) The LTC4100 is composed of a battery charger section, a charger controller, a 10-bit DAC to control charger current, an 11-bit DAC to control charger voltage, a SafetySignal decoder, limit decoder and an SMBus controller block. If no battery is present, the SafetySignal decoder indicates a RES_OR condition and charging is disabled by the charger controller (CHGEN = Low). Charging will also be disabled if DCDIV is low, or the SafetySignal is decoded as RES_HOT. If a battery is inserted and AC power is connected, the battery will be charged with an 80mA "wake-up" current. The wake-up current is discontinued after tTIMEOUT if the SafetySignal is decoded as RES_UR or RES_C0LD, and the battery or host doesn't transmit charging commands. The SMBus interface and control block receives ChargingCurrent() and ChargingVoltage() commands via the SMBus. If ChargingCurrent() and ChargingVoltage() command pairs are received within a tTIMEOUT interval, the values are stored in the current and voltage DACs and the charger controller asserts the CHGEN line if the decoded SafetySignal value will allow charging to commence. ChargingCurrent() and ChargingVoltage() values are compared against limits programmed by the limit decoder block; if the commands exceed the programmed limits these limits are substituted and overrange flags are set. The charger controller will assert SMBALERT whenever a status change is detected, namely: AC_PRESENT, 10 BATTERY_PRESENT, ALARM_INHIBITED, or VDD powerfail. The host may query the charger, via the SMBus, to obtain ChargerStatus() information. SMBALERT will be de-asserted upon a successful read of ChargerStatus() or a successful Alert Response Address (ARA) request. Battery Charger Controller The LTC4100 charger controller uses a constant off-time, current mode step-down architecture. During normal operation, the top MOSFET is turned on each cycle when the oscillator sets the SR latch and turned off when the main current comparator ICMP resets the SR latch. While the top MOSFET is off, the bottom MOSFET is turned on until either the inductor current trips the current comparator IREV, or the beginning of the next cycle. The oscillator uses the equation, tOFF = ( VDCIN - VBAT ) ( VDCIN * f OSC ) to set the bottom MOSFET on-time. The result is quasiconstant frequency operation: the converter frequency remains nearly constant over a wide range of output voltages. This activity is diagrammed in Figure 3. The peak inductor current, at which ICMP resets the SR latch, is controlled by the voltage on ITH. ITH is in turn controlled by several loops, depending upon the situation at hand. The average current control loop converts the 4100fc For more information www.linear.com/LTC4100 LTC4100 Operation Charger Start-Up voltage between CSP and BAT to a representative current. Error amp CA2 compares this current against the desired current programmed by the IDAC at the IDC pin and adjusts ITH for the desired voltage across RSENSE. When the charger is enabled, it will not begin switching until the ITH voltage exceeds a threshold that assures initial current will be positive. This threshold is 5% to 15% of the maximum programmed current. After the charger begins switching, the various loops will control the current at a level that is higher or lower than the initial current. The duration of this transient condition depends upon the loop compensation, but is typically less than 1ms. The voltage at BAT is divided down by an internal resistor divider set by the VDAC and is used by error amp EA to decrease ITH if the divider voltage is above the 1.19V reference. The amplifier CL1 monitors and limits the input current, normally from the AC adapter, to a preset level (100mV/ RCL). At input current limit, CL1 will decrease the ITH voltage to reduce charging current. SMBus Interface All communications over the SMBus are interpreted by the SMBus interface block. The SMBus interface is a SMBus slave device at address 0x12. All internal LTC4100 registers may be updated and accessed through the SMBus interface, and charger controller as required. The SMBus protocol is a derivative of the I2C bus (Reference I 2C-Bus and How to Use It, V1.0 by Philips, and System Management Bus Specification, Version 1.1, from the SBS Implementers Forum, for a complete description of the bus protocol requirements). An overvoltage comparator, OV, guards against transient overshoots (>7%). In this case, the top MOSFET is turned off until the overvoltage condition is cleared. This feature is useful for batteries that "load dump" themselves by opening their protection switch to perform functions such as calibration or pulse mode charging. PWM Watchdog Timer All data is clocked into the shift register on the rising edge of SCL. All data is clocked out of the shift register on the falling edge of SCL. Detection of an SMBus Stop condition, or power-on reset via the VDD power-fail, will reset the SMBus interface to an initial state at any time. There is a watchdog timer that observes the activity on the TGATE pin. If TGATE stops switching for more than 40s, the watchdog activates and turns off the top MOSFET for about 400ns. The watchdog engages to prevent very low frequency operation in dropout--a potential source of audible noise when using ceramic input and output capacitors. The LTC4100 command set is interpreted by the SMBus interface and passed onto the charger controller block as control signals or updates to internal registers. OFF TGATE ON ON BGATE OFF tOFF TRIP POINT SET BY ITH VOLTAGE INDUCTOR CURRENT 4100 F03 Figure 3 *http://www.SBS-FORUM.org 4100fc For more information www.linear.com/LTC4100 11 LTC4100 Operation Description of Supported Battery Charger Functions The functions are described as follows (see Table 1 also): FunctionName() `hnn (command code) Description: A brief description of the function. Purpose: The purpose of the function, and an example where appropriate. * SMBus Protocol: Refer to Section 5 of the Smart Battery Charger specification for more details. The ENABLE_POLLING bit is not supported by the LTC4100. Values written to this bit are ignored. The POR_RESET bit sets the LTC4100 to its power-on default condition. The RESET_TO_ZERO bit sets the ChargingCurrent()and ChargingVoltage() values to zero. This function ALWAYS clears the ChargingVoltage() and ChargingCurrent() values to zero even if the INHIBIT_CHARGE bit is set. ChargerStatus() (`h13) Input, Output or Input/Output: A description of the data supplied to or returned by the function. Description: The SMBus Host uses this command to read the LTC4100's status bits. ChargerSpecInfo() (`h11) Purpose: Allows the SMBus Host to determine the status and level of the LTC4100. Description: The SMBus Host uses this command to read the LTC4100's extended status bits. Purpose: Allows the System Host to determine the specification revision the charger supports as well as other extended status information. * SMBus Protocol: Read Word. Output: The CHARGER_SPEC indicates that the LTC4100 supports Version 1.1 of the Smart Battery Charger Specification. The SELECTOR_SUPPORT indicates that the LTC4100 does not support the optional Smart Battery Selector Commands. ChargerMode() (`h12) Description: The SMBus Host uses this command to set the various charger modes. The default values are set to allow a Smart Battery and the LTC4100 to work in concert without requiring an SMBus Host. Purpose: Allows the SMBus Host to configure the charger and change the default modes. This is a write only function, but the value of the "mode" bit, INHIBIT_CHARGE may be determined using the ChargerStatus() function. * SMBus Protocol: Write Word. Input: The INHIBIT_CHARGE bit allows charging to be inhibited without changing the ChargingCurrent() and ChargingVoltage() values. The charging may be resumed by clearing this bit. This bit is automatically cleared when power is reapplied or when a battery is reinserted. 12 * SMBus Protocol: Read Word. Output: The CHARGE_INHIBITED bit reflects the status of the LTC4100 set by the INHIBIT_CHARGE bit in the ChargerMode() function. The POLLING_ENABLED, VOLTAGE_NOTREG, and CURRENT_NOTREG are not supported by the LTC4100. The LTC4100 always reports itself as a Level 2 Smart Battery Charger. CURRENT_OR bit is set only when ChargingCurrent() is set to a value outside the current regulation range of the LTC4100. This bit may be used in conjunction with the INHIBIT_CHARGE bit of the ChargerMode() and ChargingCurrent() to determine the current capability of the LTC4100. When ChargingCurrent() is set to the ILIM + 1, the CURRENT_OR bit will be set. VOLTAGE_OR bit is set only when ChargingVoltage() is set to a value outside the voltage regulation range of the LTC4100. This bit may be used in conjunction with the INHIBIT_CHARGE bit of the ChargerMode() and ChargingVoltage() to determine the voltage capability of the LTC4100. When ChargingVoltage() is set to the VLIM , the VOLTAGE_OR bit will be set. The RES_OR bit is set only when the SafetySignal resistance value is greater than 95k. This indicates that the SafetySignal is to be considered as an open circuit. 4100fc For more information www.linear.com/LTC4100 LTC4100 Operation Table 1. Summary of Supported Charger Functions D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 7'b0001_001 8'h3C Read Alert Response Address 7'b0001_100 (0x18) Read Byte Reserved Ignored 1/0 1/0 Ign 1/0 0 N/A LEVEL:3/LEVEL:2 VOLTAGE_OR RES_OR RES_COLD RES_UR ALARM_INHIBITED CURRENT_OR 0 1 CHARGING_VOLTAGE[15:0] Permitted Values Unsigned integer representing voltage in mV Control Reserved Ignored 1/0 Register 0 0 0 1/0 FULLY_CHARGED Value Permitted Values Return Values Write 0 Unsigned integer representing current in mA NO_LOWI LTCO() 1 Permitted Values 1/0 1/0 1/0 1/0 Write 0 DISCHARGING 8'h16 0 Permitted Values OVER_CHARGED_ALARM 7'b0001_001 0 INITIALIZED Write 0 REMAINING_TIME_ALARM 8'h15 0 REMAINING_CAPACITY_ALARM 7'b0001_001 0 CHARGING_CURRENT[15:0] TERMINATE_DISCHARGE_ALARM Write 0 Value OVER_TEMP_ALARM 8'h14 0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 TERMINATE_CHARGE_ALARM 7'b0001_001 AlarmWarning() 0 ENABLE_POLLING Return Values Read ChargingVoltage() 0 POWER_FAIL Status BATTERY_PRESENT 8'h13 AC_PRESENT 7'b0001_001 ChargingCurrent() 0 POR_RESET 0 Permitted Values Write ChargerStatus() 0 Control RES_HOT 8'h12 Reserved 7'b0001_001 RESERVED_ALARM ChargerMode() RESET_TO_ZERO Return Values Read CHARGER_SPEC CURRENT_NOTREG Reserved D1 DO 0 INHIBIT_CHARGE Info CHARGE_INHIBITED 8'h11 POLLING_ENABLED 7'b0001_001 (0x12) 0 0 1/0 1 0 Ignored LTC4100's Version Identification Ignored 0 0 1 0 0 0 Status 0 0 0 0 Undefined Data Type VOLTAGE_NOTREG Command Code ERROR ChargerSpecInfo() SMBus Address SELECTOR_SUPPORT Access FULLY DISCHARGED Function LTC4100's Address Not Supported Return Values 0 0 0 1 0 0 1 X 4100fc For more information www.linear.com/LTC4100 13 LTC4100 Operation The RES_COLD bit is set only when the SafetySignal resistance value is greater than 28.5k. The SafetySignal indicates a cold battery. The RES_COLD bit will be set whenever the RES_OR bit is set. The RES_HOT bit is set only when the SafetySignal resistance is less than 3150, which indicates a hot battery. The RES_HOT bit will be set whenever the RES_UR bit is set. The RES_UR bit is set only when the SafetySignal resistance value is less than 575. ALARM_INHIBITED bit is set if a valid AlarmWarning() message has been received and charging is inhibited as a result. This bit is cleared if both ChargingVoltage() and ChargingCurrent() are rewritten to the LTC4100, power is removed (DCDIV < VACP), or if a battery is removed. The setting of the ALARM_INHIBITED will activate the LTC4100 SMBALERT pull-down. POWER_FAIL bit is set if the LTC4100 does not have sufficient DCIN voltage to charge the battery or if an external device is pulling the CHGEN input signal low. Charging is disabled whenever this bit is set. The setting of this bit does not clear the values in the ChargingVoltage() and ChargingCurrent() function values, nor does it necessarily affect the charging modes of the LTC4100. BATTERY_PRESENT is set if a battery is present otherwise it is cleared. The LTC4100 uses the SafetySignal in order to determine battery presence. If the LTC4100 detects a RES_OR condition, the BATTERY_PRESENT bit is cleared immediately. The LTC4100 will not set the BATTERY_PRESENT bit until it successfully samples the SafetySignal twice and does not detect a RES_OR condition on either sampling. If AC is not present (e.g. DCDIV < VACP), this bit may not be set for up to one-half second after the battery is connected to the SafetySignal. The ChargingCurrent() and ChargingVoltage() function values are immediately cleared whenever this bit is cleared. Charging will never be allowed if this bit is cleared. A change in BATTERY_PRESENT will activate the LTC4100 SMBALERT pull-down. AC_PRESENT is set if the voltage on DCDIV is greater than VACP. This does not necessarily indicate that the voltage on DCIN is sufficient to charge the battery. A change in AC_PRESENT will activate the LTC4100 SMBALERT pull-down. 14 ChargingCurrent() (`h14) Description: The Battery, System Host or other master device sends the desired charging current (mA) to the LTC4100 . Purpose: The LTC4100 uses RILIM, the granularity of the IDAC, and the value of the ChargingCurrent() function to determine its charging current supplied to the battery. The charging current will never exceed the maximum current permitted by RILIM. The ChargingCurrent() value will be truncated to the granularity of the IDAC. The charging current will also be reduced if the battery voltage exceeds the programmed charging voltage. * SMBus Protocol: Write Word. Input: The CHARGING_CURRENT is an unsigned 16 bit integer specifying the requested charging current in mA. The following table defines the maximum permissible value of CHARGING_CURRENT that will not set the CURRENT_OR in the ChargerStatus() function for a given value of the RILIM: RILIM Short to GND ChargingCurrent() Current 0x0000 through 0x03FF 0mA through 1023mA 10k 1% 0x0000 through 0x07FF 0mA through 2047mA 33k 1% 0x0000 through 0x0BFF 0mA through 3071mA Open (or Short to VDD) 0x0000 through 0x0FFF 0mA through 4095mA ChargingVoltage() (`h15) Description: The Battery, SMBus Host or other master device sends the desired charging voltage (mV) to the LTC4100. Purpose: The LTC4100 uses RVLIM, the granularity of the VDAC, and the value of the ChargingVoltage() function to determine its charging voltage supplied to the battery. The charging voltage will never be forced beyond the voltage permitted by RVLIM. The ChargingVoltage() value will be truncated to the granularity of the VDAC. The charging voltage will also be reduced if the battery current exceeds the programmed charging current. * SMBus Protocol: Write Word. Input: The CHARGING_VOLTAGE is an unsigned 16-bit integer specifying the requested charging voltage in mV. 4100fc For more information www.linear.com/LTC4100 LTC4100 Operation The LTC4100 considers any value from 0x0001 through 0x049F the same as writing 0x0000. The following table defines the maximum permissible value of CHARGING_VOLTAGE that will not set the VOLTAGE_OR in the ChargerStatus() function for a given value of RVLIM: RVLIM Maximum ChargingVoltage() Short to GND 0x225F (8796mV) 10k 1% 0x332F (13100mV) 33k 1% 0x43FF (17404mV) 100k 1% 0x54CF (21708mV) Open (or Short to VDD) 0x6D5F (27996mV) AlarmWarning() (`h16) Description: The Smart Battery, acting as a bus master device, sends the AlarmWarning() message to the LTC4100 to notify it that one or more alarm conditions exist. Alarm indications are encoded as bit fields in the Battery's Status register, which is then sent to the LTC4100 by this function. Purpose: The LTC4100 will use the information sent by this function to properly charge the battery. The LTC4100 will only respond to certain alarm bits. Writing to this function does not necessarily cause an alarm condition that inhibits battery charging. * SMBus Protocol: Write Word. Input: Only the OVER_CHARGED_ALARM, TERMINATE _CHARGE_ALARM, reserved (0x2000), and OVER _TEMP_ALARM bits are supported by the LTC4100. Writing a one to any of these specified bits will inhibit the charging by the LTC4100 and will set the ALARM_ INHIBITED bit in the ChargerStatus() function. The TERMINATE_DISCHARGE_ALARM, REMAINING_ CAPACITY_ALARM, REMAINING_TIME_ALARM, and the ERROR bits are ignored by the LTC4100. LTC0() (`h3C) Description: The SMBus Host uses this command to determine the version number of the LTC4100 and set extended operation modes not defined by the Smart Battery Charger Specification. Purpose: This function allows the SMBus Host to determine if the battery charger is an LTC4100. Identifying the manufacturer and version of the Smart Battery Charger permits software to perform tasks specific to a given charger. The LTC4100 also provides a means of disabling the LOWI current mode of the IDAC. * SMBus Protocol: Write Word. Input: The NO_LOWI is the only bit recognized by this function. The default value of NO_LOWI is zero. The LTC4100 LOWI current mode provides a more accurate average charge current when the charge current is less than 1/16 of the full scale IDAC value. When the NO_LOWI is set, a less accurate IDAC algorithm is used to generate the charging current, but because the charger is not pulsed on and off, it may be preferred. * SMBus Protocol: Read Word. Output: The NO_LOWI indicates the IDAC mode of operation. If clear, then the LOWI current mode will be used when the charging current is less than 1/16 of the fullscale IDAC value. The LTC Version Identification will always be 0x202 for the LTC4100. Alert Response Address (ARA) Description: The SMBus system host uses the Alert Response Address to quickly identify the generator of an SMBALERT# event. Purpose: The LTC4100 will respond to an ARA address 0x18 if the SMBALERT signal is actively pulling down the SMBALERT# bus. The LTC4100 will follow the prioritization reporting as defined in the System Management Bus Specification, Version 1.1, from the SBS Implementers Forum. * SMBus Protocol: A 7-bit Addressable Device Responds to an ARA. Output: The Device Address will be sent to the SMBus system host. The LTC4100 Device address is 0x12. The following events will cause the LTC4100 to pull-down the SMBALERT# bus through the SMBALERT pin: * Change of AC_PRESENT in the ChargerStatus() function. 4100fc For more information www.linear.com/LTC4100 15 LTC4100 Operation * Change of BATTERY_PRESENT in the ChargerStatus() function. * Setting ALARM_INHIBITED in the ChargerStatus() function. * Internal power-on reset condition. ChargingVoltage() request functions and broadcasting the charging commands to the LTC4100 over the SMBus. 4. The LTC4100 will still respond to Smart Battery critical warning messages without host intervention. SMBus Accelerator Pull-Ups Wake-Up Charging Mode Both SCL and SDA have SMBus accelerator circuits which reduce the rise time on systems with significant capacitance on the two SMBus signals. The dynamic pull-up circuitry detects a rising edge on SDA or SCL and applies 1mA to 10mA pull-up to VDD when VIN > 0.8V until VIN < VDD - 0.8V (external pull-up resistors are still required to supply DC current). This action allows the bus to meet SMBus rise time requirements with as much as 250pF on each SMBus signal. The improved rise time will benefit all of the devices which use the SMBus, especially those devices that use the I2C logic levels. Note that the dynamic pull-up circuits only pull to VDD, so some SMBus devices that are not compliant to the SMBus specifications may still have rise time compliance problems if the SMBus pull-up resistors are terminated with voltages higher than VDD. The following conditions must be met in order to allow wake-up charging of the battery: The Control Block 3. The successful writing of the ChargingCurrent() AND ChargingVoltage() function. The LTC4100 will proceed to the controlled charging mode after these two functions are written. The LTC4100 charger operations are handled by the control block. This block is capable of charging the selected battery autonomously or under SMBus Host control. The control block can request communications with the system management host (SMBus Host) by asserting SMBALERT = 0; this will cause the SMBus Host, if present, to poll the LTC4100. The control block receives SMBus slave commands from the SMBus interface block. The control block allows the LTC4100 to meet the following Smart Battery-controlled (Level 2) charger requirements: 1. Implements the Smart Battery's critical warning messages over the SMBus. 2. Operates as an SMBus slave device that responds to ChargingVoltage() and ChargingCurrent() commands and adjusts the charger output parameters accordingly. 3. The host may control charging by disabling the Smart Battery's ability to transmit ChargingCurrent() and 16 1. The SafetySignal must be RES_COLD, RES_IDEAL, or RES_UR. 2. AC must be present. This is qualified by DCDIV > VACP. Wake-up charging initiates when a newly inserted battery does not send ChargingCurrent() and ChargingVoltage() functions to the LTC4100. The following conditions will terminate the wake-up charging mode. 1. A TTIMEOUT period is reached when the SafetySignal is RES_COLD or RES_UR. 2. The SafetySignal is registering RES_OR. 4. The SafetySignal is registering RES_HOT. 5. The AC power is no longer present. (DCDIV < VACP) 6. The ALARM_INHIBITED becomes set in the ChargerStatus() function. 7. The INHIBIT_CHARGE is set in the ChargerMode() function. 8. The CHGEN pin is pulled low by an external device. The LTC4100 will resume wake-up charging, if the CHGEN pin is released by the external device. Toggling the CHGEN pin will not reset the TTIMEOUT timer. 9. There is insufficient DCIN voltage to charge the battery. The LTC4100 will resume wake-up charging when there is sufficient DCIN voltage to charge the battery. This condition will not reset the TTIMEOUT timer. For more information www.linear.com/LTC4100 4100fc LTC4100 Operation ChargingVoltage() AND ChargingCurrent() function values. Controlled Charging Algorithm Overview The following conditions must be met in order to allow controlled charging to start on the LTC4100: 7. RESET_TO_ZERO is set in the ChargerMode() function. 8. CHGEN pin is pulled low by an external device. The LTC4100 will resume charging using the previous ChargingVoltage() AND ChargingCurrent() function values, if the CHGEN pin is released by the external device. 1. The ChargingVoltage() AND ChargingCurrent() function must be written to non-zero values. 2. The SafetySignal must be RES_COLD, RES_IDEAL, or RES_UR. 3. AC must be present. This is qualified by DCDIV > VACP. 9. Insufficient DCIN voltage to charge the battery. The LTC4100 will resume charging using the previous ChargingVoltage() AND ChargingCurrent() function values, when there is sufficient DCIN voltage to charge the battery. The following conditions will stop the controlled charging algorithm and will cause the battery charger controller to stop charging: 1. The ChargingCurrent() AND ChargingVoltage() functions have not been written for TTIMEOUT. 10. Writing a zero value to ChargingVoltage() function. 2. The SafetySignal is registering RES_OR. 11. Writing a zero value to ChargingCurrent() function. 3. The SafetySignal is registering RES_HOT. The SafetySignal Decoder Block 4. The AC power is no longer present. (DCDIV < VACP) This block measures the resistance of the SafetySignal and features high noise immunity at critical trip points. The low power standby mode supports only battery presence SMB charger reporting requirements when AC is not present. The SafetySignal decoder is shown in Figure 4. The value of RTHA is 1.13k and RTHB is 54.9k. 5. ALARM_INHIBITED is set in the ChargerStatus() function. 6. INHIBIT_CHARGE is set in the ChargerMode() function. Clearing INHIBIT_CHARGE will cause the LTC4100 to resume charging using the previous VDD RTHA 1.13k VDD THA_SELB 16 + MUX THA - HI_REF REF LO_REF VDD RTHB 54.9k CSS THB_SELB + AC_PRESENT TH_HI VLIM RES_OR THB RSafetySignal 14 RVLIM RES_COLD LATCH + 33k SafetySignal CONTROL 15 12.5k TH_LO - 25k - + - 25k + 25k 4 ENCODER VLIM [3:0] - + RES_H0T 12.5k - RES_UR 4100 F04 Figure 4. SafetySignal Decoder Block 4100 F05 Figure 5. Simplified VLIM Circuit Concept (ILIM is Similar) 4100fc For more information www.linear.com/LTC4100 17 LTC4100 Operation SafetySignal sensing is accomplished by a state machine that reconfigures the switches of Figure 4 using THA_SELB and THB_SELB, a selectable reference generator, and two comparators. This circuit has two modes of operation based upon whether AC is present. The SafetySignal impedance is interpreted according to Table 4. SafetySignal RESISTANCE CHARGE STATUS BITS DESCRIPTION When AC is present, the LTC4100 samples the value of the SafetySignal and updates the ChargerStatus register approximately every 32ms. The state machine successively samples the SafetySignal value starting with the RES_OR RES_COLD threshold, then RES_C0LD RES_IDEAL threshold, RES_IDEAL RES_HOT threshold, and finally the RES_HOT RES_UR threshold. Once the SafetySignal range is determined, the lower value thresholds are not sampled. The SafetySignal decoder block uses the previously determined SafetySignal value to provide the appropriate adjustment in threshold to add hysteresis. The RTHB resistor value is used to measure the RES_OR RES_COLD and RES_COLD RES_IDEAL thresholds by connecting the THB pin to VDD and measuring the voltage resultant on the THA pin. The RTHA resistor value is used to measure the RES_IDEAL RES_HOT and RES_HOT RES_UR thresholds by connecting the THA pin to VDD and measuring the voltage resultant on the THB pin. 0 to 500 RES_UR RES_HOT BATTERY_PRESENT Underrange 500 to 3k RES_HOT BATTERY_PRESENT Hot 3k to 30k BATTERY_PRESENT Ideal 30k to 100k RES_COLD BATTERY_PRESENT Cold Above 100k RES_OR RES_COLD Overrange The SafetySignal decoder block uses a voltage divider network between VDD and GND to determine SafetySignal range thresholds. Since the THA and THB inputs are sequentially connected to VDD, this provides VDD noise immunity during SafetySignal measurement. When AC power is not available the SafetySignal block supports the following low power operating features: 1. The SafetySignal is sampled every 250ms or less, instead of 32ms. Table 4. SafetySignal State Ranges Note: The underrange detection scheme is a very important feature of the LTC4100. The RTHA/RSafetySignal divider trip point of 0.333 * VDD (1V) is well above the 0.047 * VDD (140mV) threshold of a system using a 10k pull-up. A system using a 10k pull-up would not be able to resolve the important underrange to hot transition point with a modest 100mV of ground offset between battery and SafetySignal detection circuitry. Such offsets are anticipated when charging at normal current levels. The required values for RTHA and RTHB are shown in Table 5. Table 5. SafetySignal External Resistor Values EXTERNAL RESISTOR VALUE () RTHA 1130 1% RTHB 54.9k 1% CSS represents the capacitance between the SafetySignal and GND. CSS may be added to provide additional noise immunity from transients in the application. CSS cannot exceed 1nF if the LTC4100 is to properly sense the value of RSafetySignal. 2. A full SafetySignal status is sampled every 30s or less, instead of every 32ms. 18 4100fc For more information www.linear.com/LTC4100 LTC4100 Operation The ILIM Decoder Block The Voltage DAC Block The value of an external resistor connected from this pin to GND determines one of four current limits that are used for maximum charging current value. These limits provide a measure of safety with a hardware restriction on charging current which cannot be overridden by software. Note that the charger output voltage is offset by VREF. Therefore, the value of VREF is subtracted from the SMBus ChargingVoltage() value in order for the output voltage to be programmed properly (without offset). If the ChargingVoltage() value is below the nominal reference voltage of the charger, nominally 1.184V, the charger output voltage is programmed to zero. In addition, if the ChargingVoltage() value is above the limit set by the VLIM pin, then the charger output voltage is set to the value determined by the VLIM resistor and the VOLTAGE_OR bit is set. These limits are demonstrated in Figure 6. Table 6. ILIM Trip Points and Ranges ILIM VOLTAGE CONTROLLED CHARGING CURRENT RANGE Short to GND VILIM < 0.09VDD 0 < I < 1023mA 1mA 10k 1% 0.17VVDD < VILIM < 0.34VVDD 0 < I < 2046mA 2mA 33k 1% 0.42VVDD < VILIM < 0.59V 0 < I < 3068mA 4mA 0.66VVDD < VILIM 0 < I < 4092mA 4mA Open (>250k, or Short to VDD) GRANULARITY 25 RVLIM = 33k 20 The VLIM Decoder Block The value of an external resistor connected from this pin to GND determines one of five voltage limits that are applied to the charger output value. These limits provide a measure of safety with a hardware restriction on charging voltage which cannot be overridden by software. CHARGER VOUT (V) EXTERNAL RESISTOR (RILIM) 15 10 5 0 0 Table 7. VLIM Trip Points and Ranges (See Figure 5) EXTERNAL RESISTOR (RVLIM) VLIM VOLTAGE 5 20 10 25 15 30 PROGRAMMED VALUE (V) 35 4100 F06 CONTROLLED CHARGING VOLTAGE (VOUT) RANGE GRANULARITY Short to GND VVLIM < 0.09VVCCP 2900mV < VOUT < 8800mV 16mV 10k 1% 0.17VVDD < VVLIM < 0.34VVDD 2900mV < VOUT < 13104mV 16mV 33k 1% 0.42VVCCP < VVLIM < 0.59VVDD 2900mV < VOUT < 17408mV 16mV 100k 1% 0.66VVDD < VVLIM < 0.84VVDD 2900mV < VOUT < 21712mV 16mV Open or Tied to VDD 0.91VVDD < VVLIM 2900mV < VOUT < 28000mV 16mV NOTE: THE LTC4100 CAN BE PROGRAMMED WITH ChargingVoltage() FUNCTION VALUES BETWEEN 1.184V AND 2.9V, HOWEVER, THE BATTERY CHARGER CONTROLLER OUTPUT VOLTAGE MAY BE ZERO WITH PROGRAMMED VALUES BELOW 2.9V. Figure 6. Transfer Function of Charger 4100fc For more information www.linear.com/LTC4100 19 LTC4100 Operation The Current DAC Block The current DAC is a delta-sigma modulator which controls the effective value of an external resistor, RSET, used to set the current limit of the charger. Figure 7 is a simplified diagram of the DAC operation. The delta-sigma modulator and switch convert the ChargingCurrent() value, received via the SMBus, to a variable resistance equal to: 1.25RSET/[ChargingCurrent()/ILIM[x]] = RIDC Therefore, programmed current is equal to: ICHARGE = (102.3mV/RSENSE) (ChargingCurrent()/ ILIM[x]), for ChargingCurrent() < ILIM[x]. When a value less than 1/16th of the maximum current allowed by ILIM is applied to the current DAC input, the current DAC enters a different mode of operation called LOWI. The current DAC output is pulse width modulated with a high frequency clock having a duty cycle value of 1/8. Therefore, the maximum output current provided by the charger is IMAX/8. The delta-sigma output gates this low duty cycle signal on and off. The delta-sigma shift registers are then clocked at a slower rate, about 45ms/ bit, so that the charger has time to settle to the IMAX/8 value. The resulting average charging current is equal to that requested by the ChargingCurrent() value. IPROG (FROM CA1 AMP) IDC RSET VREF ITH Input FET The input FET circuit performs two functions. It enables the charger if the input voltage is higher than the CLP pin, and provides an indication of this condition at both the CHGEN pin and the PWR_FAIL bit in the ChargerStatus() register. It also controls the gate of the input FET to keep a low forward voltage drop when charging and prevents reverse current flow through the input FET. If the input voltage is less than VCLP, it must go at least 130mV higher than VCLP to activate the charger. The CHGEN pin is forced low unless this condition is met. The gate of the input FET is driven to a voltage sufficient to keep a low forward voltage drop from drain to source. If the voltage between DCIN and CLP drops to less than 25mV, the input FET is turned off slowly. If the voltage between DCIN and CLP is ever less than -25mV, then the input FET is turned off quickly to prevent significant reverse current from flowing in the input FET. In this condition the CHGEN pin is driven low and the charger is disabled. The DCDIV pin is used to determine AC presence. If the DCDIV voltage is above the DCDIV comparator threshold (VACP), then the ACP output pin will be switched to VDD and the AC_PRESENT bit in the ChargerStatus() function will be set. If the DCDIV voltage is below the DCDIV comparator threshold minus the DCDIV comparator hysteresis, then the ACP output pin is switched to GND and the AC_PRESENT bit in the ChargerStatus() function is cleared. The ACP output pin is designed to drive 2mA continuously. 19 + - MODULATOR When wake-up is asserted to the current DAC block, the delta-sigma is then fixed at a value equal to 80mA, independent of the ILIM setting. The AC Present Block (AC_PRESENT) - 20 Note: The LOWI mode can be disabled by setting the NO_LOWI bit in the LTC0() function. CHARGING_CURRENT VALUE 4100 F07 Figure 7. Current DAC Operation AVERAGE CHARGER CURRENT ILIMIT/8 0 ~40ms 4100 F08 Figure 8. Charging Current Waveform in Low Current Mode 20 4100fc For more information www.linear.com/LTC4100 LTC4100 applications Information Adapter Limiting LTC4100 An important feature of the LTC4100 is the ability to automatically adjust charging current to a level which avoids overloading the wall adapter. This allows the product to operate at the same time that batteries are being charged without complex load management algorithms. Additionally, batteries will automatically be charged at the maximum possible rate of which the adapter is capable. Setting Input Current Limit To set the input current limit, you need to know the minimum wall adapter current rating. Subtract 7% for the input current limit tolerance and use that current to determine the resistor value. RCL = 100mV/ILIM ILIM = Adapter Min Current - (Adapter Min Current * 7%) 24 CL1 + 23 + This feature is created by sensing total adapter output current and adjusting charging current downward if a preset adapter current limit is exceeded. True analog control is used, with closed loop feedback ensuring that adapter load current remains within limits. Amplifier CL1 in Figure 9 senses the voltage across RCL, connected between the CLP and CLN pins. When this voltage exceeds 100mV, the amplifier will override programmed charging current to limit adapter current to 100mV/RCL. A lowpass filter formed by 4.99k and 0.1F is required to eliminate switching noise. If the current limit is not used, CLP should be connected to CLN. - 100mV 4 *RCL = CLP CLN C9 0.1F VIN RCL* R1 4.99k INFET TO LOAD 100mV ADAPTER CURRENT LIMIT 4100 F09 Figure 9. Adaptor Current Limiting As is often the case, the wall adapter will usually have at least a +10% current limit margin and many times one can simply set the adapter current limit value to the actual adapter rating (Figure 9). Charge Termination Issues Batteries with constant current charging and voltagebased charger termination might experience problems with reductions of charger current caused by adapter limiting. It is recommended that input limiting feature be defeated in such cases. Consult the battery manufacturer for information on how your battery terminates charging. Setting Output Current Limit (Refer to Figure 1) The LTC4100 current DAC and the PWM analog circuitry must coordinate the setting of the charger current. Failure to do so will result in incorrect charge currents. Table 8. Common RCL Resistor Values ADAPTER RATING (A) -7% ADAPTER RATING (A) RCL VALUE* () 1% RCL LIMIT (A) RCL POWER DISSIPATION (W) RCL POWER RATING (W) 1.5 1.40 0.068 1.47 0.15 0.25 1.8 1.67 0.062 1.61 0.16 0.25 2.0 1.86 0.051 1.96 0.20 0.25 2.3 2.14 0.047 2.13 0.21 0.25 2.5 2.33 0.043 2.33 0.23 0.50 2.7 2.51 0.039 2.56 0.26 0.50 3.0 2.79 0.036 2.79 0.28 0.50 3.3 3.07 0.033 3.07 0.31 0.50 3.6 3.35 0.030 3.35 0.33 0.50 4.0 3.72 0.027 3.72 0.37 0.50 * Rounded to nearest 5% standard step value. Many nonstandard values are popular. 4100fc For more information www.linear.com/LTC4100 21 LTC4100 Applications Information IMAX is the full-scale charge current. Chose the lowest IMAX value that is still above your expected battery charge current as requested over the SMBus. If you deviate from the resistance values shown in Table 9, it will lead to charge current gain errors. The requested current and the actual charge current applied to the battery will not be the same. The transition to low current operation begins when the inductor current reaches zero while the bottom MOSFET is on. Lower inductor values (higher IL) will cause this to occur at higher load currents, which can cause a dip in efficiency in the upper range of low current operation. In practice 10H is the lowest value recommended for use. Table 9. Recommended Resistor Values Table 10. Recommended Inductor Values IMAX (A) RSENSE () 1% RSENSE (W) RILIM () 1% 1.023 0.100 0.25 0 2.046 0.05 0.25 10k 3.068 0.025 0.5 33k 4.092 0.025 0.5 Open Warning DO NOT CHANGE THE VALUE OF RILIM DURING OPERATION. The value must remain fixed and track the RSENSE value at all times. Changing the current setting can result in currents that greatly exceed the requested value and potentially damage the battery or overload the wall adapter if no input current limiting is provided. Inductor Selection Higher operating frequencies allow the use of smaller inductor and capacitor values. A higher frequency generally results in lower efficiency because of MOSFET gate charge losses. In addition, the effect of inductor value on ripple current and low current operation must also be considered. The inductor ripple current IL decreases with higher frequency and increases with higher VIN. V 1 IL = VOUT 1- OUT (f)(L) VIN Accepting larger values of IL allows the use of low inductances, but results in higher output voltage ripple and greater core losses. A reasonable starting point for setting ripple current is IL = 0.4(IMAX). Remember the maximum IL occurs at the maximum input voltage. The inductor value also has an effect on low current operation. 22 Maximum Average Current (A) Input Voltage (V) Minimum Inductor Value (H) 1 20 40 20% 1 >20 56 20% 2 20 20 20% 2 >20 30 20% 3 20 15 20% 3 >20 20 20% 4 20 10 20% 4 >20 15 20% Charger Switching Power MOSFET and Diode Selection Two external power MOSFETs must be selected for use with the charger: a P-channel MOSFET for the top (main) switch and an N-channel MOSFET for the bottom (synchronous) switch. The peak-to-peak gate drive levels are set internally. This voltage is typically 6V. Consequently, logic-level threshold MOSFETs must be used. Pay close attention to the BVDSS specification for the MOSFETs as well; many of the logic level MOSFETs are limited to 30V or less. Selection criteria for the power MOSFETs include the onresistance RDS(ON), total gate capacitance QG, reverse transfer capacitance CRSS, input voltage and maximum output current. The charger is operating in continuous mode so the duty cycles for the top and bottom MOSFETs are given by: Main Switch Duty Cycle = VOUT/VIN Synchronous Switch Duty Cycle = (VIN - VOUT)/VIN 4100fc For more information www.linear.com/LTC4100 LTC4100 Applications Information The MOSFET power dissipations at maximum output current are given by: PMAIN = VOUT/VIN(IMAX)2(1 + T)RDS(ON) + k(VIN)2(IMAX)(CRSS)(fOSC) PSYNC = (VIN - VOUT)/VIN(IMAX)2(1 + T)RDS(ON) where T is the temperature dependency of RDS(ON) and k is a constant inversely related to the gate drive current. Both MOSFETs have I2R losses while the PMAIN equation includes an additional term for transition losses, which are highest at high input voltages. For VIN < 20V the high current efficiency generally improves with larger MOSFETs, while for VIN > 20V the transition losses rapidly increase to the point that the use of a higher RDS(ON) device with lower CRSS actually provides higher efficiency. The synchronous MOSFET losses are greatest at high input voltage or during a short circuit when the duty cycle in this switch in nearly 100%. The term (1 + T) is generally given for a MOSFET in the form of a normalized RDS(ON) vs temperature curve, but = 0.005/C can be used as an approximation for low voltage MOSFETs. CRSS = QGD/VDS is usually specified in the MOSFET characteristics. The constant k = 2 can be used to estimate the contributions of the two terms in the main switch dissipation equation. If the charger is to operate in low dropout mode or with a high duty cycle greater than 85%, then the topside Pchannel efficiency generally improves with a larger MOSFET. Using asymmetrical MOSFETs may achieve cost savings or efficiency gains. The Schottky diode D1, shown in the typical application on the back page, conducts during the dead-time between the conduction of the two power MOSFETs. This prevents the body diode of the bottom MOSFET from turning on and storing charge during the dead-time, which could cost as much as 1% in efficiency. A 1A Schottky is generally a good size for 4A regulators due to the relatively small average current. Larger diodes can result in additional transition losses due to their larger junction capacitance. The diode may be omitted if the efficiency loss can be tolerated. Calculating IC Power Dissipation The power dissipation of the LTC4100 is dependent upon the gate charge of the top and bottom MOSFETs (Q2 & Q3 respectively) The gate charge (QG) is determined from the manufacturer's data sheet and is dependent upon both the gate voltage swing and the drain voltage swing of the MOSFET. Use 6V for the gate voltage swing and VDCIN for the drain voltage swing. PD = VDCIN * (fOSC (QGQ2 + QGQ3) + IDCIN) + VDD * IDD Example: VDCIN = 19V, fOSC = 345kHz, QGQ2 = 25nC, QGQ3 = 15nC, IDCIN = 5mA, VDD = 5.5V, IDD = 1mA. PD = 428mW Calculating VDD Current The LTC4100 Vdd current, or Idd, consist of three parts: a. Irun = Current due to active clocking and bias inside the IC. b. Ithrm = Current due to thermistor circuit activity. c. Iaccel = Current due to SMBus acceleration activity. Idd = Irun + Ithrm + Iaccel a) Irun current is basically independent of SCL clock rate. Once the LTC4100 determines that there is activity on the SMBus, it turns on its internal HF oscillator. This HF oscillator remains on until a stop event occurs or SDA and SCL are at logic level 1 for the SMBus timeout period. Then it shuts off the HF oscillator. Thus, the length of the transmission and the rate of transmission bursts are more important in determining how much current the LTC4100 burns, rather than the SCL rate. In the equation below, IQ is the static current the IC consumes as a function of the Vdd voltage when not active. Since it is hard to quantify the actual messages going down the SMBus, one must estimate the SMBus activity level in term of bus utilization per second. Irun = Message Duty Cycle * 950A + (1 - Message Duty Cycle) * IQ where IQ (typical) = Vdd /47.2k 4100fc For more information www.linear.com/LTC4100 23 LTC4100 Applications Information b) Ithrm current is due to SafetySignal (thermistor pin) sampling that will vary with the presence of DC power being on or off. DCDIV is detected every 32ms. RTHX is the value of the safety signal resistance, which will vary with temperature or battery configuration. b1) Ithrm(on) when DC is on: Ithrm(On)_OverRange = 1/16 * Vdd /(54.9k + RTHX) where RTHX > 100k Ithrm(On)_Cold = 1/8 * Vdd /(54.9k + RTHX) where RTHX > 30k Ithrm(On)_normal = 1/8 * Vdd /(54.9k + RTHX) + 1/16 * Vdd/(1.13k + RTHX) Ithrm(On)_hot* = 1/8 * Vdd /(54.9k + RTHX) + 1/8 * Vdd /(1.13k + RTHX) where RTHX < 3k *= includes underrange b2) Ithrm(off) when DC is off, the thermistor monitoring rate is reduced to every 250ms or less. Ithrm(Off)_OverRange = 1/50 * Vdd /(54.9k + RTHX) where RTHX > 100K Ithrm(Off)_Cold = 1/50 * Vdd /(54.9k + RTHX) + 1/1000 * Vdd /(54.9k + RTHX) where RTHX > 30K Ithrm(Off)_normal = 1/50 * Vdd /(54.9k + RTHX) + 1/500 * Vdd /(54.9k + RTHX) + 1/1000 * Vdd /(1.13k + RTHX) Ithrm(Off)_hot* = 1/50 * Vdd /(54.9k + RTHX) + 1/500 * Vdd /(54.9k + RTHX) + 1/500 * Vdd /(1.13k + RTHX) where RTHX < 3k * includes underrange Complete Examples 1) Battery thermistor = 400, Vdd = 5.0V Battery mode (DC is off), SMBus activity is 10kHz and a 2% SMBus duty cycle, which represents a suspended or sleep condition of a notebook. Itotal = Irun + Ithrm(off) + Iaccel = 121.9A + 5.26A + 2.44A = 130A Battery mode and a 10% SMBus duty cycle, which represents an active notebook at idle. Itotal = Irun + Ithrm(off) + Iaccel = 189.5A + 5.26A + 12.2A = 207A DCIN = ON and a 20% SMBus duty cycle which represents an active notebook charging. Itotal = Irun + Ithrm(On) + Iaccel = 274A + 215.6A + 24.4A = 514A 2) Battery thermistor = 10k, Vdd = 5.0V Battery mode (DC is off), SMBus activity is 10kHz and a 2% SMBus duty cycle: Itotal = Irun + Ithrm(off) + Iaccel = 121.9A + 2.14A + 2.44A = 126A Battery mode and a 10% SMBus duty cycle: Itotal = Irun + Ithrm(off) + Iaccel = 189.5A + 2.14A + 12.2A = 204A DCIN = ON and a 20% SMBus duty cycle: Itotal = Irun + Ithrm(off) + Iaccel = 274A + 37.7A + 24.4A = 336A c) Iaccel is the current used by the SMBus accelerators. This directly depends on the SMBus frequency, duty cycle of messages sent on the SMBus and how long it takes to drive the SMBus to Vdd. Iaccel = Ipull-up * 2 * SMBus Frequency * Message Duty Cycle *Vdd /2.25V* Rise Time 24 4100fc For more information www.linear.com/LTC4100 LTC4100 Applications Information Soft-Start and Undervoltage Lockout The LTC4100 is soft-started by the 0.12F capacitor on the ITH pin. On start-up, ITH pin voltage will rise quickly to 0.5V, then ramp up at a rate set by the internal 30A pull-up current and the external capacitor. Battery charging current starts ramping up when ITH voltage reaches 0.8V and full current is achieved with ITH at 2V. With a 0.12F capacitor, time to reach full charge current is about 2ms and it is assumed that input voltage to the charger will reach full value in less than 2ms. The capacitor can be increased up to 1F if longer input start-up times are needed. In any switching regulator, conventional timer-based soft-starting can be defeated if the input voltage rises much slower than the time out period. This happens because the switching regulators in the battery charger and the computer power supply are typically supplying a fixed amount of power to the load. If input voltage comes up slowly compared to the soft-start time, the regulators will try to deliver full power to the load when the input voltage is still well below its final value. If the adapter is current limited, it cannot deliver full power at reduced output voltages and the possibility exists for a quasi "latch" state where the adapter output stays in a current limited state at reduced output voltage. For instance, if maximum charger plus computer load power is 30W, a 15V adapter might be current limited at 2.5A. If adapter voltage is less than (30W/2.5A = 12V) when full power is drawn, the adapter voltage will be pulled down by the constant 30W load until it reaches a lower stable state where the switching regulators can no longer supply full load. This situation can be prevented by utilizing the DCDIV resistor divider, set higher than the minimum adapter voltage where full power can be achieved. Input and Output Capacitors We recommend the use of high capacity low ESR/ESL X5R type ceramic capacitors. Alternative capacitors include OSCON or POSCAP type capacitors. Aluminum electrolytic capacitors are not recommended for poor ESR and ESL reasons. Solid tantalum low ESR capacitors are acceptable, but caution must be used when tantalum capacitors are used for input or output bypass. High input surge currents can be created when the power adapter is hot-plugged into the charger or when a battery is connected to the charger. Use only "surge robust" low ESR tantalums. Regardless of which type of capacitor you use, after voltage selection, the most important thing to meet is the ripple current requirements followed by the capacitance value. By the time you solve the ripple current requirements, the minimum capacitance value is often met by default. The following equation shows the minimum COUT (20% tolerance) capacitance values for stability when used with the compensation shown in the typical application on the back page. COUT(MIN) = 200/L1 The use of aluminum electrolytic for C1, located at the AC adapter input terminal, is helpful in reducing ringing during the hot-plug event. Refer to Application Note 88 for more information. In the 4A lithium battery charger (typical application on back page), the input capacitor (C2) is assumed to absorb all input switching ripple current in the converter, so it must have adequate ripple current rating. Worst-case RMS ripple current will be equal to one half of output charging current. C2 is recommended to be equal to or greater than C4 (output capacitor) in capacitance value. The output capacitor (C4) is also assumed to absorb output switching current ripple. The general formula for capacitor current is: V 0.29(VBAT ) * 1- BAT VDCIN IRMS = L1* f For example, VDCIN = 19V, VBAT = 12.6V, L1 = 10H, and f = 300kHz, IRMS = 0.41A. EMI considerations usually make it desirable to minimize ripple current in the battery leads, and beads or inductors may be added to increase battery impedance at the 300kHz switching frequency. Switching ripple current splits between the battery and the output capacitor depending on the ESR of the output capacitor and the battery impedance. If the ESR of C3 is 0.2 and the battery impedance is raised to 4 with a bead or inductor, only 5% of the current ripple will flow in the battery. 4100fc For more information www.linear.com/LTC4100 25 LTC4100 Applications Information Protecting SMBus Inputs VDD The SMBus inputs, SCL and SDA, are exposed to uncontrolled transient signals whenever a battery is connected to the system. If the battery contains a static charge, the SMBus inputs are subjected to transients which can cause damage after repeated exposure. Also, if the battery's positive terminal makes contact to the connector before the negative terminal, the SMBus inputs can be forced below ground with the full battery potential, causing a potential for latch-up in any of the devices connected to the SMBus inputs. Therefore it is good design practice to protect the SMBus inputs as shown in Figure 10. CONNECTOR TO BATTERY 4100 F10 Figure 10. Recommended SMBus Transient Protection SWITCH NODE L1 VBAT SafetySignal (Thermistor) Value The SafetySignal (typical application on back page), is a multifunction signal the communicates three pieces of information in order of importance: 1) Presence of the Smart Battery VIN C2 HIGH FREQUENCY CIRCULATING PATH D1 C4 BAT 4100 F11 2) The maximum time duration of the wake-up charge allowed. Figure 11. High Speed Switching Path 3) An optional and redundant temperature measurement system. The value of the resistance to ground communicates all this information. The resistance ranges and what it does is covered by the SBS Smart Battery Charger standard in Section 6. Basically if you have a battery chemistry, such as Li-ion, that cannot safely withstand an infinite duration wake-up charge, the SafetySignal resistance value needs to be less than 425. The popular value to use is a fixed 300 resistor. Otherwise the resistance value is 10k which is normally expected to be done using a 10k NTC resistor. 26 TO SYSTEM DIRECTION OF CHARGING CURRENT RSENSE VIAS TO CSP AND BAT 4100 F12 Figure 12. Kelvin Sensing of Charging Current 4100fc For more information www.linear.com/LTC4100 LTC4100 Applications Information PCB Layout Considerations For maximum efficiency, the switch node rise and fall times should be minimized. To prevent magnetic and electrical field radiation and high frequency resonant problems, proper layout of the components connected to the IC is essential. (See Figure 11.) Here is a PCB layout priority list for proper layout. Layout the PCB using this specific order. 1. Input capacitors need to be placed as close as possible to switching FET's supply and ground connections. Shortest copper trace connections possible. These parts must be on the same layer of copper. Vias must not be used to make this connection. 2. The control IC needs to be close to the switching FET's gate terminals. Keep the gate drive signals short for a clean FET drive. This includes IC supply pins that connect to the switching FET source pins. The IC can be placed on the opposite side of the PCB relative to above. 3. Place inductor input as close as possible to switching FET's output connection. Minimize the surface area of this trace. Make the trace width the minimum amount needed to support current--no copper fills or pours. Avoid running the connection using multiple layers in parallel. Minimize capacitance from this node to any other trace or plane. 4. Place the output current sense resistor right next to the inductor output but oriented such that the IC's current sense feedback traces going to resistor are not long. The feedback traces need to be routed together as a single pair on the same layer at any given time with smallest trace spacing possible. Locate any filter component on these traces next to the IC and not at the sense resistor location. 5. Place output capacitors next to the sense resistor output and ground. 6. Output capacitor ground connections need to feed into same copper that connects to the input capacitor ground before tying back into system ground. Interfacing with a Selector The LTC4100 is designed to be used with a true analog multiplexer for the SafetySignal sensing path. Some selector ICs from various manufacturers may not implement this. Consult LTC applications department for more information. Electronic Loads The LTC4100 is designed to work with a real battery. Electronic loads will create instability within the LTC4100 preventing accurate programming currents and voltages. Consult LTC applications department for more information. 4100fc For more information www.linear.com/LTC4100 27 LTC4100 Package Description Please refer to http://www.linear.com/designtools/packaging/ for the most recent package drawings. G Package 24-Lead Plastic SSOP (5.3mm) (Reference LTC DWG # 05-08-1640) 7.90 - 8.50* (.311 - .335) 24 23 22 21 20 19 18 17 16 15 14 13 1.25 0.12 7.8 - 8.2 5.3 - 5.7 7.40 - 8.20 (.291 - .323) 0.42 0.03 0.65 BSC RECOMMENDED SOLDER PAD LAYOUT 1 2 3 4 5 6 7 8 9 10 11 12 5.00 - 5.60** (.197 - .221) 2.0 (.079) MAX 0 - 8 0.09 - 0.25 (.0035 - .010) 0.65 (.0256) BSC 0.55 - 0.95 (.022 - .037) NOTE: 1. CONTROLLING DIMENSION: MILLIMETERS MILLIMETERS 2. DIMENSIONS ARE IN (INCHES) 0.22 - 0.38 (.009 - .015) TYP 0.05 (.002) MIN G24 SSOP 0204 3. DRAWING NOT TO SCALE *DIMENSIONS DO NOT INCLUDE MOLD FLASH. MOLD FLASH SHALL NOT EXCEED .152mm (.006") PER SIDE **DIMENSIONS DO NOT INCLUDE INTERLEAD FLASH. INTERLEAD FLASH SHALL NOT EXCEED .254mm (.010") PER SIDE 28 4100fc For more information www.linear.com/LTC4100 LTC4100 Revision History (Revision history begins at Rev B) REV DATE DESCRIPTION PAGE NUMBER B 10/09 Add Table to Typical Application Text Added to Pin Functions Text Changes to Operation Section C 02/14 1 8 11, 12, 15 Changes to Table 1 13 Added `Calculating VDD Current' Section 23 Updated `Input and Output Capacitors' Section 25 Added `SafetySignal (Thermistor) Value' Section 26 Changes to Typical Application 29 SafetySignal Trip conditions: changed the value of RTHB from 54.9 to 54.9k 4 4100fc Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights. For more information www.linear.com/LTC4100 29 LTC4100 Typical Application LTC4100 Li-Ion Battery Charger ILIM = 4A/VLIM = 17.4V, Adapter Rating = 2.7A RCL 0.033 0.5W 1% DCIN 15V TO 20V DCIN FROM WALL ADAPTER Q1 C9 0.1F 10V C1 0.1F R10 13.7k 1% 4 5 11 R11 1.21k 1% R5 6.04k 1% 19 24 CLN 1 TGATE DCIN 10 3V TO 5.5V 10k 6 10k D2 7 D3 8 SDA D4 9 SCL 100k Q2 3 ITH 18 VSET THA SMBALERT THB 16 RSNS 0.025 0.5W, 1% C4 0.01F 25V C4,C5 10F x 2 25V X5R 4-CELL Li-Ion SMART BATTERY R4 100 RTHA 1.13k 1% SafetySignal 300 SDA 15 SDA SCL D5 L1 10H 4A C5 0.1F 10V ACP CHGEN OPTIONAL DISCHARGE PATH TO SYSTEM LOAD 2 PGND ILIM D1 Q3 Q4 C2, C3 10F x 2 25V X5R DCDIV BGATE D6 DCIN 23 INFET CLP C6, 0.12F 10V, X7R LTC4100 C7, 0.0015F 10V, X7R 20 21 CSP IDC C8, 0.068F 12 10V, X7R GND 22 0.1F BAT 17 10V VDD R6, RVLIM 33k 14 VLIM 13 SYSTEM LOAD R1 4.9k 4100 TA02 SCL RTHB 54.9k 1% D1: MBRM140T3G D2-D5: SMALL SIGNAL SCHOTTKY D6: 18V ZENER DIODE Q1: 1/2 Si4925BDY Q2: FDS6685 Q3: FDC645N Q4: 1/2 Si4925 Related Parts PART NUMBER DESCRIPTION COMMENTS LTC1760 Smart Battery System Manager Autonomous Power Management and Battery Charging for Two Smart Batteries, SMBus Rev 1.1 Compliant LTC1960 Dual Battery Charger/Selector with SPI Interface Simultaneous Charge or Discharge of 2 Batteries, DAC Programmable Current and Voltage, Input Current Limiting Maximizes Charge Current LTC1980 Combination Battery Charger and DC/DC Converter Input Supply May be Above or Below Battery Voltage, up to 8.4V Float Voltage, 24-Pin SSOP Package LTC4006 Small, High Efficiency, Fixed Voltage, Lithium-Ion Battery Charger Constant Current/Constant Voltage Switching Regulator with Termination Timer, AC Adapter Current Limit and SafetySignal Sensor in a Small 16-Pin Package LTC4007 High Efficiency, Programmable Voltage Battery Charger with Termination Complete Charger for 3- or 4-Cell Li-Ion Batteries, AC Adapter Current Limit, SafetySignal Sensor and Indicator Outputs LTC4008 High Efficiency, Programmable Voltage/Current Battery Charger Constant Current/Constant Voltage Switching Regulator; Resistor Voltage/ Current Programming, AC Adapter Current Limit and SafetySignal Sensor LTC4101 Smart Battery Charger Controller For Smart Batteries with Voltages Below 5.5V LTC4412 Low Loss PowerPathTM Controller Very Low Loss Replacement for Power Supply ORing Diodes Using Minimal External Components 30 Linear Technology Corporation 1630 McCarthy Blvd., Milpitas, CA 95035-7417 For more information www.linear.com/LTC4100 (408) 432-1900 FAX: (408) 434-0507 www.linear.com/LTC4100 4100fc LT 0214 REV C * PRINTED IN USA (c) LINEAR TECHNOLOGY CORPORATION 2006