Input/Output Functional Descriptions
Symbol Type Polarity Function
CK0/CK0
CK1/CK1 IN Cross Point
The system clock input s. All ad dress and c o mmand li nes are sample d on the c ros s po int
of the rising edge of CK and falling edge of CK. A Delay Locked Loop (DLL) circuit is
driven from the cl ock inputs and outp ut timing for read operations is synchronized to the
input clock.
CKE[1:0] IN Active
High
Activates the DDR 3 SDRAM CK signal when high and deactivates the CK signal when
low. By deactivating the clocks, CKE low initiates the Power Down mode or the Self
Refresh mode.
S[1:0] IN Active
Low
Enables the associated DDR3 SDRAM command decoder when low and disables the
command decoder when high. When t he co mmand decoder is disabled, new c ommands
are ignored but previous operations continue. Rank 0 is selected by S0; Rank 1 is
selected by S1.
ODT[1:0] IN Active
High Asserts on- die terminatio n for DQ , DM, DQS, and DQS signals if enabled via the DDR3
SDRAM mode register.
RAS, CAS, WE IN Active
Low When sampled at the cross point of the rising edge of CK, signals CAS, RAS, and WE
define the operation to be executed by the SDRAM.
VREFDQ
VREFCA Supply Reference voltage for SSTL15 inputs.
BA[2:0] IN — Selects whic h SDR A M internal bank of eight is activated.
A[9:0],
A10/AP,
A11,
A12/BC
A[15:13]
IN —
During a Bank Activate command cycle, def ines the row address when sampled at the
cross point of the rising edge of CK and falling edge of CK. During a Read of Write com-
mand cycle, defines the column address when sampled at the cross point of the rising
edge of CK and falling edge of CK. In addition to the column address, AP is used to
invoke autoprecharge operation at the end of the burst read or write cycle. If AP is high
autoprecharge is selected and BA0-BAn defines the bank to be precharged. If AP is low ,
autoprecharge is disabled. During a Precharge command cycle, AP is used in conjunction
with BA0-BAn to control which bank(s) to precharge. If AP is high, all banks will be pre-
charged regardles s of the state of BA0-BAn inputs. If AP is low, then BA0-BAn are used
to define which bank to precharge. A12(BC) is samples during READ and WRITE com-
mands to determine if burst ch op (on-the-fly) will be performed (HIGH, no burst chop:
LOW, burst chopped).
DQ[63:0] I/O — Data Input/Output pins.
DM[7:0] IN Active
High
The data write masks, associated with one data byte. In Write mode, DM operates as a
byte mask by allowing input data to be written if it is low but blocks the write operation
if it is high. In Read mode, DM lines have no effect.
VDD, VDDSPD
VSS Supply Power supplies for core, I/O, Serial Presence Detect, and ground for the module.
DQS[7:0],
DQS[7:0] I/O Cross Point
The data strobes, associated with one data byte, sourced with data transfers. In Write
mode, the data strobe is sourced by the controller and is centered in the data window.
In Read mode, the data strobe is sourced by the DDR3 SDRAMs and is sent at the lead-
ing edge of the data window. DQS signals are complements, and timing is relative to the
crosspoint of respective DQS and DQS.
SA[1:0] IN — These signals are tied at the system planar to either VSS or VDDSPD to configure th e
serial SPD EEPROM address range.