http://www.tracopower.com
DC/DC Converters
TES 2M Series 2 Watt
Input Specifications
Input current no load /full load 5 Vin models: 60 mA / 600 mA typ.
12 Vin models: 30 mA / 250 mA typ.
24 Vin models: 15 mA / 125 mA typ.
Reverse voltage protection 0.3 A max.
Recommended input fuse (slow blow) 5 Vin models: 1.0 A
12 Vin models: 0.5 A
24 Vin models: 0.2 A
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
24 Vin models: 30 V max.
Input filter internal capacitors
Output Specifications
Voltage set accuracy ± 4 %
Voltage balance (dual output models) 1 % max.
Regulation – Input variation 1.2 % / 1 % change of Vin
– Load variation 20 – 100 % 10 % max.
12 % max. for 5 Vout models.
Ripple and noise (20 MHz Bandwidth) 150 mVpk-pk max.
Temperature coefficient ± 0.02 %/K
Short circuit protection 0.5 sec. max.
Minimum load 2 % of rated max current.
Capacitive load single output models: 330 µF max.
dual output models: 100 µF max. (each output)
General Specifications
Temperature ranges – Operating – 25 °C to + 75 °C
– Storage – 55 °C to + 125 °C
– Case + 110 °C max.
Derating 2.5 %/K above 60°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F ground benign) > 2.0 Mio h @ 25°C
Isolation voltage (50Hz, 60sec) – Input/Output 4000 VACrms
Isolation test voltage (1 sec.) 6000 Vpk
Leakage current (at 240VAC, 60Hz) 2 µA max.
Isolation capacity – Input/Output 20 pF max. (at 100KHz, 1V)
Isolation resistance – Input/Output >10 Gohm (at 500VDC)
Switching frequency 50 – 100 kHz (PFM)
Safety standards IEC/EN 60950-1, UL 60950-1
CSA C22.2 No. 60950-1-03
IEC/EN 60601-1, UL 60601-1,
CSA C22.2 No. 601-1
Safety approvals – CSA certificate for medical electrical equipment
www.tracopower.com/products/thi2m-csa60601.pdf
for information technology equipment
www.tracopower.com/products/thi2m-csa60950.pdf
– CB test report for medical electrical equipment
www.tracopower.com/products/thi2m-cb60601.pdf
for information technology equipment
www.tracopower.com/products/thi2m-cb60950.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.