marlow industries inc.®
Thermoelectric Cooler MI2064T
102-0124, Rev E
Performance Values
Mechanical Characteristics
1.167
[29.64]
1.167
[29.64]
Cold Side
.511
[12.98]
.511
[12.98]
.240 +/- .007
[6.10 +/- 0.18]
Positive Lead
Negative Lead
2.00 +/-.25
[50.80+/-6.35]
A
.005 [0.13]
.001 [0.03]
.003 [0.08]
22 AWG (0.64) Bus
Solid Tinned Copper
Leads:
A
Ceramic Material: Combination of
Beryllia (AB)
Alumina and
Millimeters are in [ ]
Ordering Options For example, and MI2064T with only the hot side
metallized is specified as an MI2064T-12AB
Pretinned metallized ceramic surface(s) with 117°C
solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
Hot Side Temperature (°C) 27°C 50°C
Tmax (°C-dry N2): 93 105
Qmax (watts): 10.4 11.2
Imax (amps): 5.4 5.4
Vmax (vdc): 8.6 9.6
AC Resistance (ohms): 1.43 ---
MI2064T-11 both surfaces are metallized
MI2064T-12 hot side exterior is metallized
MI2064T-13 no metallization
Tolerances are ± .030 (0.76)
unless otherwise specified
Thermoelectric Cooler MI2064T
Copyright 2002, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0124, Rev E
Performance Curves
Environment: One Atmosphere dry nitrogen
Hot Side Temperature: 27°C Hot Side Temperature: 50°C
0.0
2.0
4.0
6.0
8.0
VOLTAGE (VDC)
0.0 1.0 2.0 3.0 4.0 5.0 6.0
CURRENT (AMPS)
0.0
20.0
40.0
60.0
80.0
100.0
Q=0
HEAT
LOAD
(WATTS)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.0
0.0
2.0
4.0
6.0
8.0
10.0
VOLTAGE (VDC)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
CURRENT (AMPS)
0.0
20.0
40.0
60.0
80.0
100.0
120.0
Q=0
HEAT
LOAD
(WATTS)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.0
T (C)
T (C)
T=0 T=0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To
minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Never abrade or machine beryllium oxide (BC) ceramics without following appropriate safety procedures. Material safety
data sheets available upon request.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
TEL: 214-340-4900
FAX: 214-341-5215
Internet: http://www.marlow.com
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
TEL: +44 (0)1444-443404
FAX: +44 (0)1444-443334
Marlow Industries Asia
1-1-8-401
Uehara, Shibuya-ku
Tokyo, Japan 151-0064
TEL: +81 (3) 5454-5280
FAX: +81 (3) 5454-5281