DC AXIAL FANS
Tel: 425-222-5900 800-453-4569www.mechatronics.com E-mail: Sales@Mechatronics.com Fax: 425-222-5155 Cooling Simplified
(80 x 80 x 25 mm)
3.15 x 3.15 x 0.98 inches
Construction: UL94V-0 PBT impeller & frame
Bearing option: ball bearing or sleeve
Connection: AWG 24, UL1007 lead wires
Frame: flanged or ribbed
Protection: thermal
Options: tachometer output or locked rotor
alarm signal; thermistor speed
control; encapsulated motor;
PWM speed control
.30
.25
.20
.10
.05
010 20 30 40 50 60
AIR FLOW (CFM)
STATIC PRESSURE - IN. OF WATER
.15
S
L
M
H
E
X
F8025-H series
0.16
4x Ø 0.18
(Ø 4.5)
3.15 ±0.02
(80 ±0.5)
2.82 ±0.01
(71.5 ±0.3) 0.16
(4) (4)
0.98 ±0.02
(25 ±0.5)
Model No.
Rated
Voltage
V
Current
mA
Speed
RPM
Air Volume Max. Static
Pressure (H20)
Sound
Noise
dbA
Weight
g
12 24 /Min. CFM MM INCH
F8025S-H 12/24 75 50 2,000 0.73 26 1.75 0.07 22 82
F8025L-H 12/24 90 60 2,400 0.87 31 2.50 0.10 26 82
F8025M-H 12/24 120 80 2,800 0.99 35 3.00 0.12 29 82
F8025H-H 12/24 145 90 3,200 1.13 40 4.25 0.17 32 82
F8025E-H 12/24 240 140 3,600 1.30 46 5.25 0.21 35 82
F8025X-H 12/24 480 260 4,200 1.50 53 6.50 0.26 39 82
04.14.15