Accessories Remote Indication, Sensing Resistors REMOTE INDICATION, sensing resistors Remote Indication & Meters Product RK-302 Remote Indication and Reset Kit RK-332 Remote Indication and Reset Kit PGB-6130 Remote Indication and Reset Assembly PGB-6800 Remote Indication and Reset Assembly PGA-0500 Analog % Current Meter PGA-0510 Analog Ohm Meter E2323 & E2324 Megaohmmeter & Kiloohmmeter M8100 Synchroscope Features Accessory For Panel-mounted remote indication and reset, standard 22 mm mounting with NEMA 4 and NEMA 13 rating. SE-325 Panel-mounted remote indication and reset, standard 22 mm mounting with NEMA 4 and NEMA 13 rating. SE-330 SE-330AU SE-330HV Remote indication of overcurrent, phase unbalance, phase loss, phase sequence, and overtemperature. Remote reset included. PGR-6130 Remote indication of overcurrent, undercurrent, phase unbalance, phase loss, and phase sequence. Remote reset included. PGR-6800 Panel-mounted analog meter displays ground-fault current as a percentage of the set point. SE-601 PGR-4300 PGR-6100 SE-701 SE-703 SE-704 Panel-mounted analog ohmmeter displays insulation resistance from 0 to infinity. PGR-3200 PGR-6100 Flush-mounted units designed for connection with the T3200 for instrument readings. T3200 Flush-mounted units provide illuminaated indication of the phase and frequency difference between voltages on two separate AC systems. T5000 T4500 C6200 FlexGen S6000 Sigma Sensing Resistors Product ER-600VC (PGE-600V) Sensing Resistor SE-MRE-600 Enclosure ER-5KV (PGE-05KV) Sensing Resistor ER-5WP (PGE-05WV) Sensing Resistor Sensing Resistor ER-25KV (PGE-25KV) Sensing Resistor ER-35KV (PGE-35KV) Sensing Resistor ER-72KV (PGE-72KV) Sensing Resistor (c)2012 Littelfuse Protection Relays & Controls Used on systems up to 1 kV. (Continuous duty) Used in outdoor enclosures. (ER-600VC ordered separately) Accessory For SE-330 SE-325 SE-330AU ER-600VC Used on systems up to 5 kV. (Continuous duty) SE-330 SE-325 SE-330AU Used on systems up to 5 kV, includes weather-protected terminals for use in outdoor enclosures. (Continuous duty) SE-330 SE-325 SE-330AU Used on systems up to 15 kV. (Non-continuous duty) SE-330 SE-330HV SE-325 SE-330AU Used on systems up to 25 kV. (Non-continuous duty) SE-330 SE-330HV SE-325 SE-330AU Used on systems up to 35 kV. (Non-continuous duty) Used on systems up to 72 kV. (Non-continuous duty) 119 SE-330 SE-330HV SE-330AU SE-330HV www.littelfuse.com/relayscontrols 16 ADDITIONAL ACCESSORIES ER-15KV (PGE-15KV) Features A