CERAMIC MOLDED/MIL-C-11015 (CK) & MIL-PRF-39014 (CKR)
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-630026
KEMET
®
C062 (CK06, CKR06)
Lead Dia.
.025
(+.004
-.002)
W
.026
MIN.
H
L
S
W
.045
MAX.
H
1.25
MIN.
L
S
W
H
1.25
MIN.
L
S
W
Center Line of leads within .030" of Center Line of case.
H
1.25
MIN.
S
.026
MIN.
L
C052 (CK05, CKR05) C056 (CKR05) C066 (CKR06)
Lead Dia.
.025
(+.004
-.002)
Lead Dia.
.025
(+.004
-.002)
Lead Dia.
.025
(+.004
-.002)
1.25
MIN.
****
DIMENSIONS — INCHES & (MILLIMETERS)
CASE MILITARY
SIZE EQUIVALENT STYLES L D C
C114 CK12, CKR11 .160 ± .010 (4.06 ± .25) .090 ± .010 (2.29 ± .25) .020, +.000, -.003 (.51, +.00, -.08)
C124 CK13, CKR12 .250 ± .010 (6.35 ± .25) .090 ± .010 (2.29 ± .25) .020, +.000, -.003 (.51, +.00, -.08)
C192 CK14, CKR14 .390 ± .010 (9.91 ± .25) .140 ± .010 (3.56 ± .25) .025, +.002, -.002 (.64, +.05, -.05)
C202 CK15, CKR15 .500 ± .020 (12.70 ± .51) .250 ± .015 (6.35 ± .38) .025, +.002, -.002 (.64, +.05, -.05)
C222 CK16, CKR16 .690 ± .030 (17.53 ± .76) .350 ± .020 (8.89 ± .51) .025, +.002, -.002 (.64, +.05, -.05)
DL
C
1.50 Min.
(38.10) 1.50 Min.
(38.10)
CAPACITOR OUTLINE DRAWINGS (AXIAL LEADS)
CAPACITOR OUTLINE DRAWINGS (RADIAL LEADS)
DIMENSIONS — INCHES & (MILLIMETERS)
MILITARY S
CASE EQUIVALENT H L W LEAD
SIZE STYLES HEIGHT LENGTH WIDTH SPACING
CK05, CKR05 .190 ± .010 (4.83 ± .25) .190 ± .010 (4.83 ± .25) .090 ± .010 (2.29 ± .25) .200 ± .015 (5.08 ± .38)
CK06, CKR06 .290 ± .010 (7.37 ± .25) .290 ± .010 (7.37 ± .25) .090 ± .010 (2.29 ± .25) .200 ± .015 (5.08 ± .38)
C052/
C056
C062/
C066
*Leads are .625 minimum when tape and reel packaged.
0988 Layout rev 8/9/2000 9:54 AM Page 26
KEMET
®
CERAMIC MOLDED/MIL-C-11015 & MIL-PRF-39014
C114T (CKR11)
K
102
052 C
5
KA
X
2
C
CERAMIC
*CASE SIZE
(See Table Below)
SPECIFICATION
Military
T — MIL-PRF-39014
K — MIL-C-11015
CAPACITANCE
In picofarad code: First two digits are significant
figures and third is number of zeroes following
(except 9 indicates division by 10). Examples:
0.1 mF = 100,000 pF = 104 and 9.1 pF = 919.
See tables for Standard Values.
FAILURE RATE
INTERNAL CONSTRUCTION
CAPACITANCE TOLERANCE
Standard
M ±20%
K ±10%
A Not Applicable (Std.)
M 1.0%
P 0.1%
R 0.01%
S 0.001%
LEAD MATERIAL
C — Standard
5 — Standard
WORKING
VOLTAGE
1 100
2 200
5 50
Standard tolerances f or each Series are
shown in the repetitiv e parts lists.
*CASE SIZES
RADIAL AXIAL
C052 C114
C056 C124
C062 C192
C066 C202
C222
TEMPERATURE CHARA CTERISTIC
Capacitance Change With T emp.
Measured Measured
Without With Bias
KEMET Military EIA Temp. DC Bias (Rated
Designator Equivalent Equivalent Range, °C Voltage Voltage)
XBX X7R
-55 to ±15% +15%
(Stable) +125 -25%
RBR X7R -55 to ±15% +15%
(Stable) +125 -40%
**
**Part Number Example: C052K102K2X5CA (14 digits – no spaces)
ORDERING INFORMATION
MARKING INFORMATION
C114T (CKR11) THROUGH C222T (CKR16) PER MIL-PRF-39014
JK
103
KP0
37A
J for JAN
K for KEMET
Capacitance
Capacitance Tolerance, FR Level
& Date Code (Yr.)
Date and Lot Code
C124T (CKR12)
CKR12
2657J
0037A
31433
Style
Dash No., J for JAN
Date & Lot Code
Source Code
(Federal Supply Code
for Manufacturers,
FSCM)
C192T (CKR14) C202T (CKR15) C222T (CKR16)
M39014
5-2125
KEMET
0037A
J50V
105K
Complete Part Number
Manufacturer’s Name
Date & Lot Code
JAN & Voltage
Capacitance, pF Code, Capacitance
Tolerance
C052/56T (CKR05) PER MIL-PRF-39014/01
JK
0037
A
JAN-KEMET
Date Code
Lot Code
BACK
M390
14/01
1579*
Specification
Sheet No.
Four Digit Part No.
*Add “V” as the last
digit for stand-off leads.
FRONT
C062/66T (CKR06) PER MIL-PRF-39014/02
0037A
J200V
103K
Date & Lot Code
JAN & Voltage
Capacitance, pF Code, Capacitance Tolerance
BACK
M39014
2-1338
*KEMET
Complete MIL Part No.
Manufacturer ’s Name
FRONT
*Add “V” as the last digit
for stand-off leads.
C114K (CK12) THROUGH C222K (CK16) PER MIL-C-11015
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300 27
MIL-C-11015
MIL-PRF-39014
C114K (CK12) C124K (CK13)
KCK
12BX
102K
0037
KEMET, CK
Style (12 or 13), Temp. Char. (BX or BR)
Capacitance, pF Code, Capacitance Tolerance
Date Code
C192K (CK14) C202K (CK15) C222K (CK16)
K100V
CK14BX
123K
0037
KEMET, Voltage
Style (14, 15 or 16), Temp. Char. (BX or BR)
Capacitance, pF Code, Capacitance Tolerance
Date Code
C052K (CK05) PER MIL-C-11015/18 & C062K (CK06) PER MIL-C-11015/19
200V
K
0001
Voltage
KEMET
Date Code
BACK
CK05
BX
102K
Style
Temperature Characteristic
Capacitance, pF Code, Capacitance Tolerance
FRONT
0988 Layout rev 8/9/2000 9:54 AM Page 27
RATINGS & PART NUMBER REFERENCE
CERAMIC MOLDED/AXIAL — MIL-C-11015 & MIL-PRF-39014
STABLE TEMPERATURE CHARACTERISTICS—BX & BR (EIA-X7R)
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-630028
KEMET
®
CAP. TOL. KEMET MIL-PRF-39014/05 For Failure Rate Levels (2)
pF % PART NUMBER MIL-C-11015/20 MIL-PRF-39014/05 M P R S
100 VOLT — C114 SIZE (MILITARY—CK12 or CKR11)
10 10 C114(1)100K1X5C(2) CK12BX100K CKR11BX100K(2) 2601 2801 2001 2201
10 20 C114(1)100M1X5C(2) CK12BX100M CKR11BX100M(2) 2602 2802 2002 2202
12 10 C114(1)120K1X5C(2) CK12BX120K CKR11BX120K(2) 2603 2803 2003 2203
15 10 C114(1)150K1X5C(2) CK12BX150K CKR11BX150K(2) 2604 2804 2004 2204
15 20 C114(1)150M1X5C(2) CK12BX150M CKR11BX150M(2) 2605 2805 2005 2205
18 10 C114(1)180K1X5C(2) CK12BX180K CKR11BX180K(2) 2606 2806 2006 2206
22 10 C114(1)220K1X5C(2) CK12BX220K CKR11BX220K(2) 2607 2807 2007 2207
22 20 C114(1)220M1X5C(2) CK12BX220M CKR11BX220M(2) 2608 2808 2008 2208
27 10 C114(1)270K1X5C(2) CK12BX270K CKR11BX270K(2) 2609 2809 2009 2209
33 10 C114(1)330K1X5C(2) CK12BX330K CKR11BX330K(2) 2610 2810 2010 2210
33 20 C114(1)330M1X5C(2) CK12BX330M CKR11BX330M(2) 2611 2811 2011 2211
39 10 C114(1)390K1X5C(2) CK12BX390K CKR11BX390K(2) 2612 2812 2012 2212
47 10 C114(1)470K1X5C(2) CK12BX470K CKR11BX470K(2) 2613 2813 2013 2213
47 20 C114(1)470M1X5C(2) CK12BX470M CKR11BX470M(2) 2614 2814 2014 2214
56 10 C114(1)560K1X5C(2) CK12BX560K CKR11BX560K(2) 2615 2815 2015 2215
68 10 C114(1)680K1X5C(2) CK12BX680K CKR11BX680K(2) 2616 2816 2016 2216
68 20 C114(1)680M1X5C(2) CK12BX680M CKR11BX680M(2) 2617 2817 2017 2217
82 10 C114(1)820K1X5C(2) CK12BX820K CKR11BX820K(2) 2618 2818 2018 2218
100 10 C114(1)101K1X5C(2) CK12BX101K CKR11BX101K(2) 2619 2819 2019 2219
100 20 C114(1)101M1X5C(2) CK12BX101M CKR11BX101M(2) 2620 2820 2020 2220
120 10 C114(1)121K1X5C(2) CK12BX121K CKR11BX121K(2) 2621 2821 2021 2221
150 10 C114(1)151K1X5C(2) CK12BX151K CKR11BX151K(2) 2622 2822 2022 2222
150 20 C114(1)151M1X5C(2) CK12BX151M CKR11BX151M(2) 2623 2823 2023 2223
180 10 C114(1)181K1X5C(2) CK12BX181K CKR11BX181K(2) 2624 2824 2024 2224
220 10 C114(1)221K1X5C(2) CK12BX221K CKR11BX221K(2) 2625 2825 2025 2225
220 20 C114(1)221M1X5C(2) CK12BX221M CKR11BX221M(2) 2626 2826 2026 2226
270 10 C114(1)271K1X5C(2) CK12BX271K CKR11BX271K(2) 2627 2827 2027 2227
330 10 C114(1)331K1X5C(2) CK12BX331K CKR11BX331K(2) 2628 2828 2028 2228
330 20 C114(1)331M1X5C(2) CK12BX331M CKR11BX331M(2) 2629 2829 2029 2229
390 10 C114(1)391K1X5C(2) CK12BX391K CKR11BX391K(2) 2630 2830 2030 2230
470 10 C114(1)471K1X5C(2) CK12BX471K CKR11BX471K(2) 2631 2831 2031 2231
470 20 C114(1)471M1X5C(2) CK12BX471M CKR11BX471M(2) 2632 2832 2032 2232
560 10 C114(1)561K1X5C(2) CK12BX561K CKR11BX561K(2) 2633 2833 2033 2233
680 10 C114(1)681K1X5C(2) CK12BX681K CKR11BX681K(2) 2634 2834 2034 2234
680 20 C114(1)681M1X5C(2) CK12BX681M CKR11BX681M(2) 2635 2835 2035 2235
820 10 C114(1)821K1X5C(2) CK12BX821K CKR11BX821K(2) 2636 2836 2036 2236
1,000 10 C114(1)102K1X5C(2) CK12BX102K CKR11BX102K(2) 2637 2837 2037 2237
1,000 20 C114(1)102M1X5C(2) CK12BX102M CKR11BX102M(2) 2638 2838 2038 2238
1,200 10 C114(1)122K1X5C(2) CK12BX122K CKR11BX122K(2) 2639 2839 2039 2239
1,500 10 C114(1)152K1X5C(2) CK12BX152K CKR11BX152K(2) 2640 2840 2040 2240
1,500 20 C114(1)152M1X5C(2) CK12BX152M CKR11BX152M(2) 2641 2841 2041 2241
1,800 10 C114(1)182K1X5C(2) CK12BX182K CKR11BX182K(2) 2642 2842 2042 2242
2,200 10 C114(1)222K1X5C(2) CK12BX222K CKR11BX222K(2) 2643 2843 2043 2243
2,200 20 C114(1)222M1X5C(2) CK12BX222M CKR11BX222M(2) 2644 2844 2044 2244
2,700 10 C114(1)272K1X5C(2) CK12BX272K CKR11BX272K(2) 2645 2845 2045 2245
3,300 10 C114(1)332K1X5C(2) CK12BX332K CKR11BX332K(2) 2646 2846 2046 2246
3,300 20 C114(1)332M1X5C(2) CK12BX332M CKR11BX332M2) 2647 2847 2047 2247
3,900 10 C114(1)392K1X5C(2) CK12BX392K CKR11BX392K(2) 2648 2848 2048 2248
4,700 10 C114(1)472K1X5C(2) CK12BX472K CKR11BX472K(2) 2649 2849 2049 2249
4,700 20 C114(1)472M1X5C(2) CK12BX472M CKR11BX472M2) 2650 2850 2050 2250
50 VOLT — C114 SIZE (MILITARY—CK12 or CKR11)
5,600 10 C114(1)562K5X5C(2) CK12BX562K CKR11BX562K(2) 2651 2851 2051 2251
6,800 10 C114(1)682K5X5C(2) CK12BX682K CKR11BX682K(2) 2652 2852 2052 2252
6,800 20 C114(1)682M5X5C(2) CK12BX682M CKR11BX682M(2) 2653 2853 2053 2253
8,200 10 C114(1)822K5X5C(2) CK12BX822K CKR11BX822K(2) 2654 2854 2054 2254
10,000 10 C114(1)103K5X5C(2) CK12BX103K CKR11BX103K(2) 2655 2855 2055 2255
10,000 20 C114(1)103M5X5C(2) CK12BX103M CKR11BX103M(2) 2656 2856 2056 2256
100 VOLT — C124 SIZE (MILITARY—CK13 or CKR12)
5,600 10 C124(1)562K1X5C(2) CK13BX562K CKR12BX562K(2) 2657 2857 2057 2257
6,800 10 C124(1)682K1X5C(2) CK13BX682K CKR12BX682K(2) 2658 2858 2058 2258
6,800 20 C124(1)682M1X5C(2) CK13BX682M CKR12BX682M(2) 2659 2859 2059 2259
8,200 10 C124(1)822K1X5C(2) CK13BX822K CKR12BX822K(2) 2660 2860 2060 2260
10,000 10 C124(1)103K1X5C(2) CK13BX103K CKR12BX103K(2) 2661 2861 2061 2261
10,000 20 C124(1)103M1X5C(2) CK13BX103M CKR12BX103M(2) 2662 2862 2062 2262
50 VOLT — C124 SIZE (MILITARY—CK13 or CKR12)
12,000 10 C124(1)123K5X5C(2) CK13BX123K CKR12BX123K(2) 2663 2863 2063 2263
15,000 10 C124(1)153K5X5C(2) CK13BX153K CKR12BX153K(2) 2664 2864 2064 2264
15,000 20 C124(1)153M5X5C(2) CK13BX153M CKR12BX153M(2) 2665 2865 2065 2265
18,000 10 C124(1)183K5X5C(2) CK13BX183K CKR12BX183K(2) 2666 2866 2066 2266
22,000 10 C124(1)223K5X5C(2) CK13BX223K CKR12BX223K(2) 2667 2867 2067 2267
22,000 20 C124(1)223M5X5C(2) CK13BX223M CKR12BX223M(2) 2668 2868 2068 2268
27,000 10 C124K273K5R5CA CK13BR273K
33,000 10 C124K333K5R5CA CK13BR333K
33,000 20 C124K333M5R5CA CK13BR333M
39,000 10 C124K393K5R5CA CK13BR393K
47,000 10 C124K473K5R5CA CK13BR473K
47,000 20 C124K473M5R5CA CK13BR473M
(1) Insert proper letter for specification: K — MIL-C-11015; T — MIL-PRF-39014 (2) Failure Rate Designator: A — Not applicable (MIL-C-11015); M — 1%/1000 Hours,
P — .1%/1000 Hours, R — .01%/1000 Hours, S — .001%/1000 Hours (MIL-PRF-39014)
0988 Layout rev 8/9/2000 9:54 AM Page 28
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300 29
KEMET
®
CERAMIC MOLDED/AXIAL — MIL-C-11015 & MIL-PRF-39014
STABLE TEMPERATURE CHARACTERISTICS—BX & BR (EIA-X7R)
MIL-C-11015
MIL-PRF-39014
RATINGS & PART NUMBER REFERENCE
CAP. TOL. KEMET MIL-PRF-39014/05 For Failure Rate Levels (2)
pF % PART NUMBER MIL-C-11015/20 MIL-PRF-39014/05 M P R S
50 VOLT — C124 SIZE (MILITARY—CK13 or CKR12) (Cont’d)
27,000 10 C124T273K5X5C(2) CKR12BX273K(2) 2669 2869 2069 2269
33,000 10 C124T333K5X5C(2) CKR12BX333K(2) 2670 2870 2070 2270
33,000 20 C124T333M5X5C(2) CKR12BX333M(2) 2671 2871 2071 2271
39,000 10 C124T393K5X5C(2) CKR12BX393K(2) 2672 2872 2072 2272
47,000 10 C124T473K5X5C(2) CKR12BX473K(2) 2673 2873 2073 2273
47,000 20 C124T473M5X5C(2) CKR12BX473M(2) 2674 2874 2074 2274
100 VOLT — C192 SIZE (MILITARY—CK14 or CKR14)
12,000 10 C192(1)123K1X5C(2) CK14BX123K CKR14BX123K(2) 2675 2875 2075 2275
15,000 10 C192(1)153K1X5C(2) CK14BX153K CKR14BX153K(2) 2676 2876 2076 2276
15,000 20 C192(1)153M1X5C(2) CK14BX153M CKR14BX153M(2) 2677 2877 2077 2277
18,000 10 C192(1)183K1X5C(2) CK14BX183K CKR14BX183K(2) 2678 2878 2078 2278
22,000 10 C192(1)223K1X5C(2) CK14BX223K CKR14BX223K(2) 2679 2879 2079 2279
22,000 20 C192(1)223M1X5C(2) CK14BX223M CKR14BX223M(2) 2680 2880 2080 2280
27,000 10 C192(1)273K1X5C(2) CK14BX273K CKR14BX273K(2) 2681 2881 2081 2281
33,000 10 C192(1)333K1X5C(2) CK14BX333K CKR14BX333K(2) 2682 2882 2082 2282
33,000 20 C192(1)333M1X5C(2) CK14BX333M CKR14BX333M(2) 2683 2883 2083 2283
39,000 10 C192(1)393K1X5C(2) CK14BX393K CKR14BX393K(2) 2684 2884 2084 2284
47,000 10 C192(1)473K1X5C(2) CK14BX473K CKR14BX473K(2) 2685 2885 2085 2285
47,000 20 C192(1)473M1X5C(2) CK14BX473M CKR14BX473M(2) 2686 2886 2086 2286
56,000 10 C192(1)563K1R5C(2) CK14BR563K CKR14BR563K(2) 2693 2893 2093 2293
68,000 10 C192(1)683K1R5C(2) CK14BR683K CKR14BR683K(2) 2694 2894 2094 2294
68,000 20 C192(1)683M1R5C(2) CK14BR683M CKR14BR683M(2) 2695 2895 2095 2295
82,000 10 C192(1)823K1R5C(2) CK14BR823K CKR14BR823K(2) 2696 2896 2096 2296
100,000 10 C192(1)104K1R5C(2) CK14BR104K CKR14BR104K(2) 2697 2897 2097 2297
100,000 20 C192(1)104M1R5C(2) CK14BR104M CKR14BR104M(2) 2698 2898 2098 2298
50 VOLT — C192 SIZE (MILITARY—CK14 or CKR14)
56,000 10 C192T563K5X5C(2) CKR14BX563K(2) 2687 2887 2087 2287
68,000 10 C192T683K5X5C(2) CKR14BX683K(2) 2688 2888 2088 2288
68,000 20 C192T683M5X5C(2) CKR14BX683M(2) 2689 2889 2089 2289
82,000 10 C192T823K5X5C(2) CKR14BX823K(2) 2690 2890 2090 2290
100,000 10 C192T104K5X5C(2) CKR14BX104K(2) 2691 2891 2091 2291
100,000 20 C192T104M5X5C(2) CKR14BX104M(2) 2692 2892 2092 2292
120,000 10 C192(1)124K5R5C(2) CK14BR124K CKR14BR124K(2) 2699 2899 2099 2299
150,000 10 C192(1)154K5R5C(2) CK14BR154K CKR14BR154K(2) 2700 2900 2100 2300
150,000 20 C192(1)154M5R5C(2) CK14BR154M CKR14BR154M(2) 2701 2901 2101 2301
180,000 10 C192(1)184K5R5C(2) CK14BR184K CKR14BR184K(2) 2702 2902 2102 2302
220,000 10 C192(1)224K5R5C(2) CK14BR224K CKR14BR224K(2) 2703 2903 2103 2303
220,000 20 C192(1)224M5R5C(2) CK14BR224M CKR14BR224M(2) 2704 2904 2104 2304
270,000 10 C192(1)274K5R5C(2) CK14BR274K CKR14BR274K(2) 2705 2905 2105 2305
100 VOLT — C202 SIZE (MILITARY—CK15 or CKR15)
56,000 10 C202T563K1X5C(2) CKR15BX563K(2) 2706 2906 2106 2306
68,000 10 C202T683K1X5C(2) CKR15BX683K(2) 2707 2907 2107 2307
68,000 20 C202T683M1X5C(2) CKR15BX683M(2) 2708 2908 2108 2308
82,000 10 C202T823K1X5C(2) CKR15BX823K(2) 2709 2909 2109 2309
100,000 10 C202(1)104K1X5C(2) CK15BX104K CKR15BX104K(2) 2710 2910 2110 2310
100,000 20 C202(1)104M1X5C(2) CK15BX104M CKR15BX104M(2) 2711 2911 2111 2311
120,000 10 C202(1)124K1R5C(2) CK15BR124K CKR15BR124K(2) 2712 2912 2112 2312
150,000 10 C202(1)154K1R5C(2) CK15BR154K CKR15BR154K(2) 2713 2913 2113 2313
150,000 20 C202(1)154M1R5C(2) CK15BR154M CKR15BR154M(2) 2714 2914 2114 2314
180,000 10 C202(1)184K1R5C(2) CK15BR184K CKR15BR184K(2) 2715 2915 2115 2315
220,000 10 C202(1)224K1R5C(2) CK15BR224K CKR15BR224K(2) 2716 2916 2116 2316
220,000 20 C202(1)224M1R5C(2) CK15BR224M CKR15BR224M(2) 2717 2917 2117 2317
270,000 10 C202(1)274K1R5C(2) CK15BR274K CKR15BR274K(2) 2718 2918 2118 2318
330,000 10 C202(1)334K1R5C(2) CK15BR334K CKR15BR334K(2) 2719 2919 2119 2319
330,000 20 C202(1)334M1R5C(2) CK15BR334M CKR15BR334M(2) 2720 2920 2120 2320
50 VOLT — C202 SIZE (MILITARY—CK15 or CKR15)
470,000 10 C202(1)474K5R5C(2) CK15BR474K CKR15BR474K(2) 2721 2921 2121 2321
470,000 20 C202(1)474M5R5C(2) CK15BR474M CKR15BR474M(2) 2722 2922 2122 2322
680,000 10 C202T684K5R5C(2) CKR15BR684K(2) 2723 2923 2123 2323
680,000 20 C202T684M5R5C(2) CKR15BR684M(2) 2724 2924 2124 2324
1,000,000 10 C202(1)105K5R5C(2) CK15BR105K CKR15BR105K(2) 2725 2925 2125 2325
1,000,000 20 C202(1)105M5R5C(2) CK15BR105M CKR15BR105M(2) 2726 2926 2126 2326
100 VOLT — C222 SIZE (MILITARY—CK16 or CKR16)
470,000 10 C222(1)474K1R5C(2) CK16BR474K CKR16BR474K(2) 2727 2927 2127 2327
470,000 20 C222(1)474M1R5C(2) CK16BR474M CKR16BR474M(2) 2728 2928 2128 2328
680,000 10 C222T684K1R5C(2) CKR16BR684K(2) 2729 2929 2129 2329
680,000 20 C222T684M1R5C(2) CKR16BR684M(2) 2730 2930 2130 2330
1,000,000 10 C222(1)105K1R5C(2) CK16BR105K CKR16BR105K(2) 2731 2931 2131 2331
1,000,000 20 C222(1)105M1R5C(2) CK16BR105M CKR16BR105M(2) 2732 2932 2132 2332
50 VOLT — C222 SIZE (MILITARY—CK16 or CKR16)
2,200,000 10 C222(1)225K5R5C(2) CK16BR225K CKR16BR225K(2) 2733 2933 2133 2333
2,200,000 20 C222(1)225M5R5C(2) CK16BR225M CKR16BR225M(2) 2734 2934 2134 2334
3,300,000 10 C222(1)335K5R5C(2) CK16BR335M CKR16BR335K(2) 2735 2935 2135 2335
3,300,000 20 C222(1)335M5R5C(2) CK16BR335M CKR16BR335M(2) 2736 2936 2136 2336
(1) Insert proper letter for specification: K — MIL-C-11015; T — MIL-PRF-39014 (2) Failure Rate Designator: A — Not applicable (MIL-C-11015); M — 1%/1000 Hours,
P — .1%/1000 Hours, R — .01%/1000 Hours, S — .001%/1000 Hours (MIL-PRF-39014)
0988 Layout rev 8/9/2000 9:54 AM Page 29
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300
CERAMIC MOLDED/RADIAL — MIL-C-11015 & MIL-PRF-39014
STABLE TEMPERATURE CHARACTERISTICS—BX & BR (EIA-X7R)
30
KEMET
®
RATINGS & PART NUMBER REFERENCE
CAP. TOL. KEMET MIL-PRF-39014/01 For Failure Rate Levels (2)
pF % PART NUMBER MIL-C-11015/18 MIL-PRF-39014/01 M P R S
200 VOLT — C052/C056 SIZE (MILITARY—CK05 or CKR05)
10 10 C05(4)(1)100K2X5C(2) CK05BX100K CKR05BX100K(2)(3) 1201(3) 1241(3) 1281(3) 1321(3)
10 20 C05(4)(1)100M2X5C(2) CK05BX100M CKR05BX100M(2)(3) 1202(3) 1242(3) 1282(3) 1322(3)
12 10 C05(4)(1)120K2X5C(2) CK05BX120K CKR05BX120K(2)(3) 1203(3) 1243(3) 1283(3) 1323(3)
15 10 C05(4)(1)150K2X5C(2) CK05BX150K CKR05BX150K(2)(3) 1204(3) 1244(3) 1284(3) 1324(3)
15 20 C05(4)(1)150M2X5C(2) CK05BX150M CKR05BX150M(2)(3) 1205(3) 1245(3) 1285(3) 1325(3)
18 10 C05(4)(1)180K2X5C(2) CK05BX180K CKR05BX180K(2)(3) 1206(3) 1246(3) 1286(3) 1326(3)
22 10 C05(4)(1)220K2X5C(2) CK05BX220K CKR05BX220K(2)(3) 1207(3) 1247(3) 1287(3) 1327(3)
22 20 C05(4)(1)220M2X5C(2) CK05BX220M CKR05BX220M(2)(3) 1208(3) 1248(3) 1288(3) 1328(3)
27 10 C05(4)(1)270K2X5C(2) CK05BX270K CKR05BX270K(2)(3) 1209(3) 1249(3) 1289(3) 1329(3)
33 10 C05(4)(1)330K2X5C(2) CK05BX330K CKR05BX330K(2)(3) 1210(3) 1250(3) 1290(3) 1330(3)
33 20 C05(4)(1)330M2X5C(2) CK05BX330M CKR05BX330M(2)(3) 1211(3) 1251(3) 1291(3) 1331(3)
39 10 C05(4)(1)390K2X5C(2) CK05BX390K CKR05BX390K(2)(3) 1212(3) 1252(3) 1292(3) 1332(3)
47 10 C05(4)(1)470K2X5C(2) CK05BX470K CKR05BX470K(2)(3) 1213(3) 1253(3) 1293(3) 1333(3)
47 20 C05(4)(1)470M2X5C(2) CK05BX470M CKR05BX470M(2)(3) 1214(3) 1254(3) 1294(3) 1334(3)
56 10 C05(4)(1)560K2X5C(2) CK05BX560K CKR05BX560K(2)(3) 1215(3) 1255(3) 1295(3) 1335(3)
68 10 C05(4)(1)680K2X5C(2) CK05BX680K CKR05BX680K(2)(3) 1216(3) 1256(3) 1296(3) 1336(3)
68 20 C05(4)(1)680M2X5C(2) CK05BX680M CKR05BX680M(2)(3) 1217(3) 1257(3) 1297(3) 1337(3)
82 10 C05(4)(1)820K2X5C(2) CK05BX820K CKR05BX820K(2)(3) 1218(3) 1258(3) 1298(3) 1338(3)
100 10 C05(4)(1)101K2X5C(2) CK05BX101K CKR05BX101K(2)(3) 1219(3) 1259(3) 1299(3) 1339(3)
100 20 C05(4)(1)101M2X5C(2) CK05BX101M CKR05BX101M(2)(3) 1220(3) 1260(3) 1300(3) 1340(3)
120 10 C05(4)(1)121K2X5C(2) CK05BX121K CKR05BX121K(2)(3) 1221(3) 1261(3) 1301(3) 1341(3)
150 10 C05(4)(1)151K2X5C(2) CK05BX151K CKR05BX151K(2)(3) 1222(3) 1262(3) 1302(3) 1342(3)
150 20 C05(4)(1)151M2X5C(2) CK05BX151M CKR05BX151M(2)(3) 1223(3) 1263(3) 1303(3) 1343(3)
180 10 C05(4)(1)181K2X5C(2) CK05BX181K CKR05BX181K(2)(3) 1224(3) 1264(3) 1304(3) 1344(3)
220 10 C05(4)(1)221K2X5C(2) CK05BX221K CKR05BX221K(2)(3) 1225(3) 1265(3) 1305(3) 1345(3)
220 20 C05(4)(1)221M2X5C(2) CK05BX221M CKR05BX221M(2)(3) 1226(3) 1266(3) 1306(3) 1346(3)
270 10 C05(4)(1)271K2X5C(2) CK05BX271K CKR05BX271K(2)(3) 1227(3) 1267(3) 1307(3) 1347(3)
330 10 C05(4)(1)331K2X5C(2) CK05BX331K CKR05BX331K(2)(3) 1228(3) 1268(3) 1308(3) 1348(3)
330 20 C05(4)(1)331M2X5C(2) CK05BX331M CKR05BX331M(2)(3) 1229(3) 1269(3) 1309(3) 1349(3)
390 10 C05(4)(1)391K2X5C(2) CK05BX391K CKR05BX391K(2)(3) 1230(3) 1270(3) 1310(3) 1350(3)
470 10 C05(4)(1)471K2X5C(2) CK05BX471K CKR05BX471K(2)(3) 1231(3) 1271(3) 1311(3) 1351(3)
470 20 C05(4)(1)471M2X5C(2) CK05BX471M CKR05BX471M(2)(3) 1232(3) 1272(3) 1312(3) 1352(3)
560 10 C05(4)(1)561K2X5C(2) CK05BX561K CKR05BX561K(2)(3) 1233(3) 1273(3) 1313(3) 1353(3)
680 10 C05(4)(1)681K2X5C(2) CK05BX681K CKR05BX681K(2)(3) 1234(3) 1274(3) 1314(3) 1354(3)
680 20 C05(4)(1)681M2X5C(2) CK05BX681M CKR05BX681M(2)(3) 1235(3) 1275(3) 1315(3) 1355(3)
820 10 C05(4)(1)821K2X5C(2) CK05BX821K CKR05BX821K(2)(3) 1236(3) 1276(3) 1316(3) 1356(3)
1,000 10 C05(4)(1)102K2X5C(2) CK05BX102K CKR05BX102K(2)(3) 1237(3) 1277(3) 1317(3) 1357(3)
1,000 20 C05(4)(1)102M2X5C(2) CK05BX102M CKR05BX102M(2)(3) 1238(3) 1278(3) 1318(3) 1358(3)
100 VOLT — C052/C056 SIZE (MILITARY—CK05 or CKR05)
1,200 10 C05(4)(1)122K1X5C(2) CK05BX122K CKR05BX122K(2)(3) 1239(3) 1279(3) 1319(3) 1359(3)
1,500 10 C05(4)(1)152K1X5C(2) CK05BX152K CKR05BX152K(2)(3) 1240(3) 1280(3) 1320(3) 1360(3)
1,500 20 C05(4)(1)152M1X5C(2) CK05BX152M CKR05BX152M(2)(3) 1441(3) 1481(3) 1521(3) 1561(3)
1,800 10 C05(4)(1)182K1X5C(2) CK05BX182K CKR05BX182K(2)(3) 1442(3) 1482(3) 1522(3) 1562(3)
2,200 10 C05(4)(1)222K1X5C(2) CK05BX222K CKR05BX222K(2)(3) 1443(3) 1483(3) 1523(3) 1563(3)
2,200 20 C05(4)(1)222M1X5C(2) CK05BX222M CKR05BX222M(2)(3) 1444(3) 1484(3) 1524(3) 1564(3)
2,700 10 C05(4)(1)272K1X5C(2) CK05BX272K CKR05BX272K(2)(3) 1445(3) 1485(3) 1525(3) 1565(3)
3,300 10 C05(4)(1)332K1X5C(2) CK05BX332K CKR05BX332K(2)(3) 1446(3) 1486(3) 1526(3) 1566(3)
3,300 20 C05(4)(1)332M1X5C(2) CK05BX332M CKR05BX332M(2)(3) 1447(3) 1487(3) 1527(3) 1567(3)
3,900 10 C05(4)(1)392K1X5C(2) CK05BX392K CKR05BX392K(2)(3) 1448(3) 1488(3) 1528(3) 1568(3)
4,700 10 C05(4)(1)472K1X5C(2) CK05BX472K CKR05BX472K(2)(3) 1449(3) 1489(3) 1529(3) 1569(3)
4,700 20 C05(4)(1)472M1X5C(2) CK05BX472M CKR05BX472M(2)(3) 1450(3) 1490(3) 1530(3) 1570(3)
5,600 10 C05(4)(1)562K1X5C(2) CK05BX562K CKR05BX562K(2)(3) 1451(3) 1491(3) 1531(3) 1571(3)
6,800 10 C05(4)(1)682K1X5C(2) CK05BX682K CKR05BX682K(2)(3) 1452(3) 1492(3) 1532(3) 1572(3)
6,800 20 C05(4)(1)682M1X5C(2) CK05BX682M CKR05BX682M(2)(3) 1453(3) 1493(3) 1533(3) 1573(3)
8,200 10 C05(4)(1)822K1X5C(2) CK05BX822K CKR05BX822K(2)(3) 1454(3) 1494(3) 1534(3) 1574(3)
10,000 10 C05(4)(1)103K1X5C(2) CK05BX103K CKR05BX103K(2)(3) 1455(3) 1495(3) 1535(3) 1575(3)
10,000 20 C05(4)(1)103M1X5C(2) CK05BX103M CKR05BX103M(2)(3) 1456(3) 1496(3) 1536(3) 1576(3)
50 VOLT — C052/C056 SIZE (MILITARY—CK05 or CKR05)
12,000 10 C05(4)(1)123K5X5C(2) CK05BX123K CKR05BX123K(2)(3) 1457(3) 1497(3) 1537(3) 1577(3)
15,000 10 C05(4)(1)153K5X5C(2) CK05BX153K CKR05BX153K(2)(3) 1458(3) 1498(3) 1538(3) 1578(3)
15,000 20 C05(4)(1)153M5X5C(2) CK05BX153M CKR05BX153M(2)(3) 1459(3) 1499(3) 1539(3) 1579(3)
18,000 10 C05(4)(1)183K5X5C(2) CK05BX183K CKR05BX183K(2)(3) 1460(3) 1500(3) 1540(3) 1580(3)
22,000 10 C05(4)(1)223K5X5C(2) CK05BX223K CKR05BX223K(2)(3) 1461(3) 1501(3) 1541(3) 1581(3)
22,000 20 C05(4)(1)223M5X5C(2) CK05BX223M CKR05BX223M(2)(3) 1462(3) 1502(3) 1542(3) 1582(3)
27,000 10 C05(4)(1)273K5X5C(2) CK05BX273K CKR05BX273K(2)(3) 1463(3) 1503(3) 1543(3) 1583(3)
33,000 10 C05(4)(1)333K5X5C(2) CK05BX333K CKR05BX333K(2)(3) 1464(3) 1504(3) 1544(3) 1584(3)
33,000 20 C05(4)(1)333M5X5C(2) CK05BX333M CKR05BX333M(2)(3) 1465(3) 1505(3) 1545(3) 1585(3)
39,000 10 C05(4)(1)393K5X5C(2) CK05BX393K CKR05BX393K(2)(3) 1466(3) 1506(3) 1546(3) 1586(3)
47,000 10 C05(4)(1)473K5X5C(2) CK05BX473K CKR05BX473K(2)(3) 1467(3) 1507(3) 1547(3) 1587(3)
47,000 20 C05(4)(1)473M5X5C(2) CK05BX473M CKR05BX473M(2)(3) 1468(3) 1508(3) 1548(3) 1588(3)
56,000 10 C05(4)(1)563K5X5C(2) CK05BX563K CKR05BX563K(2)(3) 1469(3) 1509(3) 1549(3) 1589(3)
68,000 10 C05(4)(1)683K5X5C(2) CK05BX683K CKR05BX683K(2)(3) 1470(3) 1510(3) 1550(3) 1590(3)
68,000 20 C05(4)(1)683M5X5C(2) CK05BX683M CKR05BX683M(2)(3) 1471(3) 1511(3) 1551(3) 1591(3)
82,000 10 C05(4)(1)823K5X5C(2) CK05BX823K CKR05BX823K(2)(3) 1472(3) 1512(3) 1552(3) 1592(3)
100,000 10 C05(4)(1)104K5X5C(2) CK05BX104K CKR05BX104K(2)(3) 1473(3) 1513(3) 1553(3) 1593(3)
100,000 20 C05(4)(1)104M5X5C(2) CK05BX104M CKR05BX104M(2)(3) 1474(3) 1514(3) 1554(3) 1594(3)
(1) Insert proper letter for specification: K — MIL-C-11015; T — MIL-PRF-39014 (2) Failure Rate Designator: A — Not applicable (MIL-C-11015); M — 1%/1000 Hours,
P — .1%/1000 Hours, R — .01%/1000 Hours, S — .001%/1000 Hours (MIL-PRF-39014)
(3) Insert “V” for standard design (C056). Leave blank for the flat bottom design (C052).
(4) Insert “2” for standard design (Style C052) Note: Stand-offs are available only
Insert “6” for stand-off design (Style C056) with the CKR, not the CK.
}
0988 Layout rev 8/9/2000 9:54 AM Page 30
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300 31
KEMET
®
CERAMIC MOLDED/RADIAL — MIL-C-11015 & MIL-PRF-39014
STABLE TEMPERATURE CHARACTERISTICS—BX & BR (EIA-X7R)
MIL-C-11015
MIL-PRF-39014
RATINGS & PART NUMBER REFERENCE
CAP. TOL. KEMET MIL-PRF-39014/02 For Failure Rate Levels (2)
pF % PART NUMBER MIL-C-11015/19 MIL-PRF-39014/02 M P R S
200 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
1,200 10 C06(4)(1)122K2X5C(2) CK06BX122K CKR06BX122K(2)(3) 1201(3) 1241(3) 1281(3) 1321(3)
1,500 10 C06(4)(1)152K2X5C(2) CK06BX152K CKR06BX152K(2)(3) 1202(3) 1242(3) 1282(3) 1322(3)
1,500 20 C06(4)(1)152M2X5C(2) CK06BX152M CKR06BX152M(2)(3) 1203(3) 1243(3) 1283(3) 1323(3)
1,800 10 C06(4)(1)182K2X5C(2) CK06BX182K CKR06BX182K(2)(3) 1204(3) 1244(3) 1284(3) 1324(3)
2,200 10 C06(4)(1)222K2X5C(2) CK06BX222K CKR06BX222K(2)(3) 1206(3) 1246(3) 1286(3) 1326(3)
2,200 20 C06(4)(1)222M2X5C(2) CK06BX222M CKR06BX222M(2)(3) 1207(3) 1247(3) 1287(3) 1327(3)
2,700 10 C06(4)(1)272K2X5C(2) CK06BX272K CKR06BX272K(2)(3) 1208(3) 1248(3) 1288(3) 1328(3)
3,300 10 C06(4)(1)332K2X5C(2) CK06BX332K CKR06BX332K(2)(3) 1209(3) 1249(3) 1289(3) 1329(3)
3,300 20 C06(4)(1)332M2X5C(2) CK06BX332M CKR06BX332M(2)(3) 1210(3) 1250(3) 1290(3) 1330(3)
3,900 10 C06(4)(1)392K2X5C(2) CK06BX392K CKR06BX392K(2)(3) 1211(3) 1251(3) 1291(3) 1331(3)
4,700 10 C06(4)(1)472K2X5C(2) CK06BX472K CKR06BX472K(2)(3) 1212(3) 1252(3) 1292(3) 1332(3)
4,700 20 C06(4)(1)472M2X5C(2) CK06BX472M CKR06BX472M(2)(3) 1213(3) 1253(3) 1293(3) 1333(3)
5,600 10 C06(4)(1)562K2X5C(2) CK06BX562K CKR06BX562K(2)(3) 1214(3) 1254(3) 1294(3) 1334(3)
6,800 10 C06(4)(1)682K2X5C(2) CK06BX682K CKR06BX682K(2)(3) 1215(3) 1255(3) 1295(3) 1335(3)
6,800 20 C06(4)(1)682M2X5C(2) CK06BX682M CKR06BX682M(2)(3) 1216(3) 1256(3) 1296(3) 1336(3)
8,200 10 C06(4)(1)822K2X5C(2) CK06BX822K CKR06BX822K(2)(3) 1217(3) 1257(3) 1297(3) 1337(3)
10,000 10 C06(4)(1)103K2X5C(2) CK06BX103K CKR06BX103K(2)(3) 1218(3) 1258(3) 1298(3) 1338(3)
10,000 20 C06(4)(1)103M2X5C(2) CK06BX103M CKR06BX103M(2)(3) 1219(3) 1259(3) 1299(3) 1339(3)
100 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
12,000 10 C06(4)(1)123K1X5C(2) CK06BX123K CKR06BX123K(2)(3) 1231(3) 1271(3) 1311(3) 1351(3)
15,000 10 C06(4)(1)153K1X5C(2) CK06BX153K CKR06BX153K(2)(3) 1220(3) 1260(3) 1300(3) 1340(3)
15,000 20 C062K153M1X5CA CK06BX153M
18,000 10 C06(4)(1)183K1X5C(2) CK06BX183K CKR06BX183K(2)(3) 1221(3) 1261(3) 1301(3) 1341(3)
22,000 10 C06(4)(1)223K1X5C(2) CK06BX223K CKR06BX223K(2)(3) 1222(3) 1262(3) 1302(3) 1342(3)
22,000 20 C062K223M1X5CA CK06BX223M
27,000 10 C06(4)(1)273K1X5C(2) CK06BX273K CKR06BX273K(2)(3) 1232(3) 1272(3) 1312(3) 1352(3)
33,000 10 C06(4)(1)333K1X5C(2) CK06BX333K CKR06BX333K(2)(3) 1223(3) 1263(3) 1303(3) 1343(3)
33,000 20 C062K333M1X5CA CK06BX333M
39,000 10 C06(4)(1)393K1X5C(2) CK06BX393K CKR06BX393K(2)(3) 1224(3) 1264(3) 1304(3) 1344(3)
47,000 10 C06(4)(1)473K1X5C(2) CK06BX473K CKR06BX473K(2)(3) 1225(3) 1265(3) 1305(3) 1345(3)
47,000 20 C062K473M1X5CA CK06BX473M
56,000 10 C06(4)(1)563K1X5C(2) CK06BX563K CKR06BX563K(2)(3) 1226(3) 1266(3) 1306(3) 1346(3)
68,000 10 C06(4)(1)683K1X5C(2) CK06BX683K CKR06BX683K(2)(3) 1227(3) 1267(3) 1307(3) 1347(3)
68,000 20 C062K683M1X5CA CK06BX683M
82,000 10 C06(4)(1)823K1X5C(2) CK06BX823K CKR06BX823K(2)(3) 1229(3) 1269(3) 1309(3) 1349(3)
100,000 10 C06(4)(1)104K1X5C(2) CK06BX104K CKR06BX104K(2)(3) 1230(3) 1270(3) 1310(3) 1350(3)
100,000 20 C062K104M1X5CA CK06BX104M
50 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
120,000 10 C06(4)(1)124K5X5C(2) CK06BX124K CKR06BX124K(2)(3) 1233(3) 1273(3) 1313(3) 1353(3)
150,000 10 C06(4)(1)154K5X5C(2) CK06BX154K CKR06BX154K(2)(3) 1234(3) 1274(3) 1314(3) 1354(3)
150,000 20 C062K154M5X5CA CK06BX154M
180,000 10 C06(4)(1)184K5X5C(2) CK06BX184K CKR06BX184K(2)(3) 1235(3) 1275(3) 1315(3) 1355(3)
220,000 10 C06(4)(1)224K5X5C(2) CK06BX224K CKR06BX224K(2)(3) 1236(3) 1276(3) 1316(3) 1356(3)
220,000 20 C062K224M5X5CA CK06BX224M
270,000 10 C06(4)(1)274K5X5C(2) CK06BX274K CKR06BX274K(2)(3) 1237(3) 1277(3) 1317(3) 1357(3)
330,000 10 C06(4)(1)334K5X5C(2) CK06BX334K CKR06BX334K(2)(3) 1238(3) 1278(3) 1318(3) 1358(3)
330,000 20 C062K334M5X5CA CK06BX334M
390,000 10 C06(4)(1)394K5X5C(2) CK06BX394K CKR06BX394K(2)(3) 1239(3) 1279(3) 1319(3) 1359(3)
470,000 10 C06(4)(1)474K5X5C(2) CK06BX474K CKR06BX474K(2)(3) 1240(3) 1280(3) 1320(3) 1360(3)
470,000 20 C062K474M5X5CA CK06BX474M
560,000 10 C06(4)(1)564K5X5C(2) CK06BX564K CKR06BX564K(2)(3) 1404(3) 1408(3) 1412(3) 1416(3)
680,000 10 C06(4)(1)684K5X5C(2) CK06BX684K CKR06BX684K(2)(3) 1405(3) 1409(3) 1413(3) 1417(3)
680,000 20 C062K684M5X5CA CK06BX684M
820,000 10 C06(4)(1)824K5X5C(2) CK06BX824K CKR06BX824K(2)(3) 1406(3) 1410(3) 1414(3) 1418(3)
1,000,000 10 C06(4)(1)105K5X5C(2) CK06BX105K CKR06BX105K(2)(3) 1407(3) 1411(3) 1415(3) 1419(3)
1,000,000 20 C062K105M5X5CA CK06BX105M
(1) Insert proper letter for specification: K — MIL-C-11015; T — MIL-PRF-39014.
(2) Failure Rate Designator: A — Not applicable (MIL-C-11015); M — 1%/1000 Hours, P — .1%/1000 Hours, R — .01%/1000 Hours, S — .001%/1000 Hours (MIL-PRF-39014)
(3) Add “V” for stand-off design (C066). Leave blank for the flat bottom design (C062).
(4) Insert “2” for standard design (Style C062). Insert “6” for stand-off design (Style C066). Note: Stand-offs are available only with the CKR, not the CK.
0988 Layout rev 8/9/2000 9:54 AM Page 31