Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
HIGH FREQUENCY CHARACTERISTICS (Impedance 50)
Notes: *1 The 6GHz type only has the above characteristics up to 6GHz.
*2 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer)
ORDERING INFORMATION
Addition of
6GHz High Reliability
RD Coaxial Switch (SPDT)
for Communications Market
RD COAXIAL
SWITCHES (ARD)
Frequency to 1 GHz 1 to 4 GHz 4 to 8 GHz*18 to 12.4 GHz 12.4 to 18 GHz 18 to 26.5 GHz*2
V. S.W.R. (max.) 1.1 1.15 1.25 1.35 1.5 1.7
V. S.W.R. (SP6T With termination) (max.) 1.20 1.40 1.50
Insertion loss (dB. max.) 0.2 0.3 0.4 0.5 0.8
Isolation (dB. min.) 85 80 70 65 60 55
6GHz type
RoHS compliant
FEATURES
1. Excellent high frequency
characteristics (50, to 26.5Ghz)
2. SPDT, Transfer and SP6T types are
available.
3. High sensitivity
Nominal operating power:
840 mW (SPDT/SP6T, Fail-safe type,
with indicator)
1,540 mW (Transfer, Fail-safe type, with
indicator)
*Without 24V type
4. Long-lasting life: min. 5 × 106
5. With termination type is added.
(SP6T)
Thanks to the addition of termination,
steady high frequency characteristics can
be maintained when contacts are either
open or closed and this contributes to
increase system reliability.
6. + COM type is available.
TYPICAL APPLICATIONS
Wireless and mobile communication
• Cellular phone base station
• Amplifier switching
Digital broadcasting
• Broadcasting relay station
• Broadcasting equipment
Measuring instrument
All types of inspection equipment
Please inquire beforehand if you are
thinking of using this product in
applications that involve low level load or
high frequency of switching.
Frequency
1: to 18GHz (SPDT)
2: to 18GHz (Transfer)
3: to 13GHz (SP6T)
5: to 26.5GHz (SPDT)
6: to 26.5GHz (Transfer)
7: to 6GHz (SPDT)
RD coaxial switches
ARD
Operating function
00: Fail-safe (with indicator)
20: Latching (with indicator)
51: Latching with TTL driver (SPDT, Transfer)
(with self cut-off function) (with indicator)
02: Fail-safe (without indicator)
22: Latching (without indicator)
53: Latching with TTL driver (SPDT)
(with self cut-off function) (without indicator)
Nominal operating voltage, V DC
4H:
05:
12: 12
24: 24
4.5 (Fail-safe, Latching type only)
5 (Latching with TTL driver type only)
Operation terminal
Nil:
C:
Solder terminal
Connector cable (SPDT type only)
Termination (SP6T type only)
Nil:
Z:
No termination
With termination
HF data attached
Nil:
Q:
No HF test data attached
HF test data attached
Note: Sealed types also available, please consult us (SPDT only)
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
TYPES
1. SPDT
1) Solder terminal
Note: Standard packing; Carton: 1 pc. Case: 20 pcs.
2) Connector cable
Note: Standard packing; Carton: 1 pc. Case: 10 pcs.
2. Transfer
Note: Standard packing; Carton: 1 pc. Case: 10 pcs.
3. SP6T
Note: Standard packing; Carton: 1 pc. Case: 5 pcs.
Operating function Nominal operating
voltage, V DC
6GHz type 18GHz type 26.5GHz type
No HF datasheet
attached
No HF datasheet
attached
HF datasheet
attached
No HF datasheet
attached
HF datasheet
attached
Fail-safe
(with indicator)
4.5 ARD7004H ARD1004H ARD1004HQ ARD5004H ARD5004HQ
12 ARD70012 ARD10012 ARD10012Q ARD50012 ARD50012Q
24 ARD70024 ARD10024 ARD10024Q ARD50024 ARD50024Q
Latching
(with indicator)
4.5 ARD7204H ARD1204H ARD1204HQ ARD5204H ARD5204HQ
12 ARD72012 ARD12012 ARD12012Q ARD52012 ARD52012Q
24 ARD72024 ARD12024 ARD12024Q ARD52024 ARD52024Q
Latching with TTL driver
(with self cut-off function)
(with indicator)
5 ARD75105 ARD15105 ARD15105Q ARD55105 ARD55105Q
12 ARD75112 ARD15112 ARD15112Q ARD55112 ARD55112Q
24 ARD75124 ARD15124 ARD15124Q ARD55124 ARD55124Q
Fail-safe
(without indicator)
4.5 ARD7024H
————12 ARD70212
24 ARD70224
Latching
(without indicator)
4.5 ARD7224H
————12 ARD72212
24 ARD72224
Latching with TTL driver
(with self cut-off function)
(without indicator)
5 ARD75305
————12 ARD75312
24 ARD75324
Operating function Nominal operating
voltage, V DC
18GHz type 26.5GHz type
No HF datasheet attached HF datasheet attached No HF datasheet attached HF datasheet attached
Fail-safe
4.5 ARD1004HC ARD1004HCQ ARD5004HC ARD5004HCQ
12 ARD10012C ARD10012CQ ARD50012C ARD50012CQ
24 ARD10024C ARD10024CQ ARD50024C ARD50024CQ
Latching
4.5 ARD1204HC ARD1204HCQ ARD5204HC ARD5204HCQ
12 ARD12012C ARD12012CQ ARD52012C ARD52012CQ
24 ARD12024C ARD12024CQ ARD52024C ARD52024CQ
Latching with TTL driver
(with self cut-off function)
5 ARD15105C ARD15105CQ ARD55105C ARD55105CQ
12 ARD15112C ARD15112CQ ARD55112C ARD55112CQ
24 ARD15124C ARD15124CQ ARD55124C ARD55124CQ
Operating function Nominal operating
voltage, V DC
18GHz type 26.5GHz type
No HF datasheet attached HF datasheet attached No HF datasheet attached HF datasheet attached
Fail-safe
4.5 ARD2004H ARD2004HQ ARD6004H ARD6004HQ
12 ARD20012 ARD20012Q ARD60012 ARD60012Q
24 ARD20024 ARD20024Q ARD60024 ARD60024Q
Latching
4.5 ARD2204H ARD2204HQ ARD6204H ARD6204HQ
12 ARD22012 ARD22012Q ARD62012 ARD62012Q
24 ARD22024 ARD22024Q ARD62024 ARD62024Q
Latching with TTL driver
(with self cut-off function)
5 ARD25105 ARD25105Q ARD65105 ARD65105Q
12 ARD25112 ARD25112Q ARD65112 ARD65112Q
24 ARD25124 ARD25124Q ARD65124 ARD65124Q
Operating function Nominal operating
voltage, V DC
13GHz type
No HF datasheet attached HF datasheet attached
Fail-safe
4.5 ARD3004H ARD3004HQ
12 ARD30012 ARD30012Q
24 ARD30024 ARD30024Q
Latching
4.5 ARD3204H ARD3204HQ
12 ARD32012 ARD32012Q
24 ARD32024 ARD32024Q
New
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
4. SP6T (with termination)
Note: Standard packing; Carton: 1 pc. Case: 5 pcs.
RATING
1. Coil data
(1) SPDT
1) Fail-safe type
2) Latching type
3) Latching with TTL driver type
(2) Transfer
1) Fail-safe type
2) Latching type
3) Latching with TTL driver type (with self cut-off function)
(3) SP6T and SP6T (with termination type)
1) Fail-safe type
2) Latching type
Operating function Nominal operating
voltage, V DC
13GHz type
No HF datasheet attached HF datasheet attached
Fail-safe
4.5 ARD3004HZ ARD3004HZQ
12 ARD30012Z ARD30012ZQ
24 ARD30024Z ARD30024ZQ
Latching
4.5 ARD3204HZ ARD3204HZQ
12 ARD32012Z ARD32012ZQ
24 ARD32024Z ARD32024ZQ
Nominal operating voltage,
V DC
Nominal operating current, mA (+10%/–15%) (at 20°C 68°F) Nominal power consumption, mW
With indicator Without indicator With indicator Without indicator
4.5 186.7 155.6 840 70012 70.0 58.3
24 40.4 29.2 970
Nominal operating voltage,
V DC
Nominal operating current, mA (+10%/–15%) (at 20°C 68°F) Nominal power consumption, mW
With indicator Without indicator With indicator Without indicator
4.5 155.6 111.1 700
50012 62.5 41.7 750
24 37.5 16.7 900
Nominal operating voltage,
V DC
TTL logic level (see TTL logic level range) Electronic self cut-off Switching frequency
ON OFF
5
2.4 to 5.5V 0 to 0.5V Available Max. 180 cpm
(ON time : OFF time = 1 : 1)
12
24
Nominal operating voltage,
V DC
Nominal operating current, mA
(+10%/–15%) (at 20°C 68°F)Nominal power consumption, mW
4.5 342.2 1540
12 128.3
24 69.6 1670
Nominal operating voltage,
V DC
Nominal operating current, mA
(+10%/–15%) (at 20°C 68°F)Nominal power consumption, mW
4.5 266.7 1200
12 104.2 1250
24 58.3 1400
Nominal operating voltage,
V DC
TTL logic level (see TTL logic level range) Electronic self cut-off Switching frequency
ON OFF
5
2.4 to 5.5V 0 to 0.5V Available Max. 180 cpm
(ON time : OFF time = 1 : 1)
12
24
Nominal operating voltage,
V DC
Nominal operating current, mA
(+10%/–15%) (at 20°C 68°F)Nominal power consumption, mW
4.5 186.7 840
12 70.0
24 40.4 970
Nominal operating voltage,
V DC
Nominal operating current, mA
(+10%/–15%) (at 20°C 68°F)Nominal power consumption, mW
4.5 SET: 155.6 / RESET (ALL): 933.6 SET: 700 / RESET (ALL): 4,200
12 SET: 62.5 / RESET (ALL): 375.0 SET: 750 / RESET (ALL): 4,500
24 SET: 37.5 / RESET (ALL): 225.0 SET: 900 / RESET (ALL): 5,400
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
• Operating voltage range
1) Fail-safe type 2) Latching type 3) Latching with TTL driver type
(with self cut-off function)
0
4
32
24
28
8
16
12
20
0
2
16
12
14
4
8
6
10
–55–40 0–20 20
Ambient temperature °C
Voltage VDC
12
V
0
0.75
6
4.5
5.25
1.5
3
2.25
3.75
4.5
V
24
V
8540 60
Nominal voltage
Allowable range
for use
Recommended
operation voltage range
Recommended
release voltage range
0
4
32
24
28
8
16
12
20
0
2
16
12
14
4
8
6
10
–55–40 0–20 20 8540 60
Ambient temperature °C
12
V
0
0.75
6
4.5
5.25
1.5
3
2.25
3.75
4.5
V
24
V
Allowable range
for use
Recommended
set/reset voltage range
Nominal voltage
0
4
32
24
28
8
16
12
20
0
2
16
12
14
4
8
6
10
–55–40 0–20 20 8540 60
Ambient temperature °C
12
V
0
0.83
6.67
5
5.83
1.67
3.33
2.5
4.17
5
V
24
V
Nominal voltage
Allowable range
for use
Recommended set/reset
voltage range
4) TTL Logic level range
Note: Please consult us for use that is outside this
range.
Ambient temperature °C
Voltage VDC
0
0.5
5.5
4
3
2.4
5
1
2
–55–40 0–20 20 8540 60
ON
OFF
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
2. Specifications
1) SPDT/Transfer
Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use.
*2 The 6GHz type only has the above characteristics up to 6GHz.
*3 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer)
*4 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
Characteristics Item Specifications
Contact
Arrangement SPDT Transfer
Contact material Gold plating
Initial contact resistance Max. 100m (By voltage drop 6V DC 1A)
Rating
Contact input power
120W (at 3GHz)
(V.S.W.R. 1.15 or less, no contact switching,
ambient temperature 40°C 104°F [SPDT], 25°C 77°F [Transfer])*1
Nominal
operating
power
Fail-safe 840mW (4.5V, 12V DC), 970mW (24V DC) 1,540mW (4.5V, 12V DC), 1,670mW (24V DC)
Latching 700mW (4.5V DC), 750mW (12V DC),
900mW (24V DC)
1,200mW (4.5V DC), 1,250mW (12V DC),
1,400mW (24V DC)
Indicator rating (with
indicator type only)
Contact rating Max. 30V 100mA
Initial contact resistance Max. 1 (Measured by 5V 100mA)
Min. switching capacity
(Reference value) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3k))
High frequency
characteristics
(Impedance 50)
to 1 GHz 1 to 4 GHz 4 to 8 GHz*28 to 12.4 GHz 12.4 to 18 GHz 18 to 26.5
GHz*3
V. S.W.R. (max.) 1.1 1.15 1.25 1.35 1.5 1.7
Insertion loss (dB, max.) 0.2 0.3 0.4 0.5 0.8
Isolation (dB, min.) 85 80 70 65 60 55
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
Breakdown
voltage
(Initial)
Between open
contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and coil 500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and earth terminal 500 Vrms for 1 min. (Detection current: 10mA)
Between coil and
earth terminal 500 Vrms for 1 min. (Detection current: 10mA)
Time characteristics
(at 20°C 68°F)Operate time Max. 15ms (Nominal operating voltage applied to
the coil, excluding contact bounce time.)
Max. 20ms (Nominal operating voltage applied to
the coil, excluding contact bounce time.)
Mechanical
characteristics
Shock
resistance
Functional Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5mm
Expected life
Mechanical
6GHz type: Min. 106
18 and 26.5GHz type: Min. 5 × 106
(All types, at 180 cpm)
Min. 5 × 106
(at 180 cpm)
Electrical
High frequency
contact (Hot switch)
6GHz type: Min. 106
18 and 26.5GHz type: Min. 5 × 106
(All types, 5W to 3GHz, impedance 50,
V. S.W.R.; max. 1.2) (at 20 cpm)
Min. 5 × 106
(5W to 3GHz, impedance 50, V.S.W.R.; max. 1.2)
(at 20 cpm)
Indicator (with
indicator type only) 5 V DC, 10 mA, Min. 106 (at 20 cpm)
Conditions Conditions for operation,
transport and storage*4
Ambient temperature: –55°C to +85°C –67°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 50g 1.76oz Approx. 110g 3.88oz
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
2) SP6T
Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use.
*2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
Characteristics Item Specifications
Contact
Arrangement SP6T
Contact material Gold plating
Initial contact resistance Max. 100m (By voltage drop 6V DC 1A)
Rating
Contact
input power
No termination 120 W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1
With termination 2W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1
Nominal
operating
power
Fail-safe 840mW (4.5V, 12V DC), 970mW (24V DC)
Latching 700mW (4.5V DC), 750mW (12V DC), 900mW (24V DC)
Indicator rating
Contact rating Max. 30V 100mA
Initial contact resistance Max. 1 (Measured by 5V 100mA)
Min. switching capacity
(Reference value) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3k))
High frequency
characteristics
(Impedance 50)
to 1 GHz 1 to 4 GHz 4 to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz
V. S . W.R.
(max.)
No termination 1.1 1.15 1.25 1.35 1.50
With termination 1.20 1.40 1.50 1.50
Insertion loss (dB, max.) 0.2 0.3 0.4 1.0
Isolation (dB, min.) 85 80 70 65 60
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
Breakdown
voltage
(Initial)
Between open
contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and coil 500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and earth terminal 500 Vrms for 1 min. (Detection current: 10mA)
Between coil and
earth terminal 500 Vrms for 1 min. (Detection current: 10mA)
Time characteristics
(at 20°C 68°F)Operate time Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Shock
resistance
Functional Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5mm
Expected life
Mechanical Min. 5 × 106 (at 180 cpm)
Electrical
High frequency
contact (Hot switch)
No termination Min. 5 × 106 (5W to 3GHz, impedance 50, V.S.W.R.; max. 1.2) (at 20 cpm)
With termination Min. 5 × 106 (2W to 3GHz, impedance 50, V.S.W.R.; max. 1.2) (at 20 cpm)
Indicator (with
indicator type only) 5 VDC, 10 mA, Min. 106 (at 20 cpm)
Conditions Conditions for operation,
transport and storage*2
Ambient temperature: –55°C to +85°C –67°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 320g 11.29oz
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
REFERENCE DATA
1-(1). High frequency characteristics (SPDT) 6GHz type
Sample: ARD70012
Measuring method: Measured with Agilent Technologies network analyzer (E8363B).
V.S.W.R. • Insertion loss • Isolation
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
8GHz1GHz 4GHz 6GHz30MHz
Standard value
V. S . W.R.
Frequency
Reference
value
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
8GHz1GHz 4GHz 6GHz30MHz
Standard value
Frequency
Reference
value
Insertion loss, dB
0
10
20
30
40
50
60
70
80
90
100
8GHz1GHz 4GHz 6GHz30MHz
Standard value
Frequency
Reference
value
Isolation, dB
1-(2). High frequency characteristics (SPDT) 18, 26.5GHz type
Sample: ARD10012
Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
V.S.W.R. • Insertion loss • Isolation
1.1
1.0
1.9
1.2
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
1.4
1.5
1.6
1.7
1.8
1.3
Frequency
V.S.W.R.
Standard value
Reference value
0.8
0.7
1.0
0.9
0
0.2
0.1
0.6
0.4
0.5
0.3
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
Frequency
Insertion loss, dB
Standard value
Reference value
80
90
100
0
10
20
60
70
30
40
50
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
Frequency
Isolation, dB
Standard value
Reference value
1-(3). High frequency characteristics (Transfer)
Sample: ARD60012
Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
V.S.W.R. • Insertion loss • Isolation
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
1.1
1.0
1.9
1.2
1.4
1.5
1.6
1.7
1.8
1.3
Frequency
V.S.W.R.
Standard value
Reference value
0.8
0.9
1.0
0
0.1
0.2
0.6
0.7
0.3
0.4
0.5
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
Frequency
Insertion loss, dB
Standard value
Reference value
1GHz 4GHz
12.4GHz8GHz 18GHz 26.5GHz
80
70
100
90
0
20
10
60
40
50
30
Isolation, dB
Frequency
Standard value
Reference value
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
1-(4). High frequency characteristics (SP6T)
Sample: ARD30012
Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
V.S.W.R. • Insertion loss • Isolation
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1GHz 8GHz4GHz 12.4GHz 18GHz
Frequency
V.S.W.R.
Standard value
Reference value
1.0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1GHz 8GHz4GHz 12.4GHz 18GHz
Frequency
Insertion loss, dB
Standard value
Reference value
100
0
10
20
30
40
50
60
70
80
90
1GHz 8GHz4GHz 12.4GHz 18GHz
Isolation, dB
Frequency
Standard value
Reference value
• Termination characteristics
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1GHz 8GHz4GHz 12.4GHz 18GHz
Reference value
Standard value
V.S.W.R.
Frequency
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
DIMENSIONS (mm inch)
+ COM type is available
* The type without indicator terminals will not have the indicator terminals that are marked with the dotted box.
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. SPDT
1) Solder terminal
6GHz type
18 and 26.5GHz types
Tolerance: ±0.3 ±.012
+
GND
NONC
COM
Indicator
Serial No.
Coil
3-SMA connector
3.5
34.0
11.2
.441 13.2
.520
22.4
30.0
1.339
.882
1.181
7.0
.276
3.5
2.0
.138
.138 3.5
.138
.079 0.3
.012
7.2
.283
Solder terminal
2-3.1 dia.
11.2
.441
2-.122 dia.
2-2.4 dia.
2-.094 dia.
4.3
.169
39.0
1.535
7.3 2.1
.287 .083
4.5
.177
Fail-safe Latching Latching with TTL driver
(with self cut-off function)
NONC COM
Coil
Serial No.
Indicator
COM
NC N O
GND
+
GND
21 COM
Coil 1
Coil 2
Serial No.
Indicator
Coil
COM
12
GND
2
1
GND Coil terminal
Indicator terminal
Logic 2
21COM
Logic 1
Serial No.
21
1
COM
Coil
GND
2V
Indicator
GNDV
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
2) Connector cable
COM
NC N O
GND
+
Coil
Indicator
Serial No.
D-sub connector
pin contact type
25.0
3-SMA connector
34.0
11.2
.441
13.2
.520
22.4
30.0
1.339
.882
1.181
30.8
.984
1.213
1
Pin No. 2345
6789
7.2
.283
110.0±10
39.0
2-2.4 dia.
4.331±.394
1.535
2-.094 dia.
12.55
.494
3.05 dia.
.120 dia.
5.95
.234
1.2
.047
2.1
4.5
.177
7.3 .083.287
2-3.1 dia.
2-.122 dia.
Tolerance: ±0.3 ±.012
Fail-safe Latching Latching with TTL driver
(with self cut-off function)
COMNC NO
GND
Indicator terminal
Coil terminal
Indicator terminal
Coil terminal
Coil 2
Coil 1
COM12
GND
Indicator terminal
Coil terminal
Logic 1 Logic 2
V
COM12
GND
+ COM type is available
Indicator Coil
Pin No. 123456789
Fail-safe NC COM NO GND +
Latching 1 COM 2 GND 1 2
Latching with
TTL driver –1COM 2 V GND Logic 1 Logic 2
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
+ COM type is available
2. Transfer
J4
J3
J2
J1
Coil
GND
+
NC
NO
COM
Serial No.
Indicator
J3 J4
J2
J1
32.0
16.2
4-SMA connector
5.08 5.08
.200 .200
45.70
55.5
1.260
.638
2.185
5.08
.200
0.30
.012
15.24
1.799
.600 2.00
.079 Solder terminal
10.15
.400
9.65
.380 39.0
1.535
7.2
.283
Max. 5.0
.197
16.2
.638
32.0
1.260
20.3
9.65
.799
.380
3-3.80 dia.
3-.150 dia.
1 to 1.5
.039 to .059
Tolerance: ±0.3 ±.012
Fail-safe NC: J1-J2, J3-J4
NO: J1-J3, J2-J4
Latching POS1: J1-J2, J3-J4
POS2: J1-J3, J2-J4
Latching with TTL driver POS1: J1-J2, J3-J4
POS2: J1-J3, J2-J4
J2
J4
J1
J3
Fail-safe Latching Latching with TTL driver
(with self cut-off function)
NO
NC
COM
GND
Coil terminal Indicator terminal
1
2
GND
2
COM
1
Coil terminal Indicator terminal
V
GND
Logic 1
Logic 2
1
COM
2
Coil terminal Indicator terminal
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
+ COM type is available.
3. SP6T
JAPAN
Coil
J1
J6
J3
COM
63
5
Serial No.
IN
MADE
4
J2
J4
J5
COM
1
(Bottm view)
Ind
GND
5
1
4263
2
J3
J5
J2
J1
J6
COM J4
7-SMA jack connector
4-4.5 dia.
4-.177 dia.
80.0
7-5.08
7-.200
66.0
78.0 dia.
56.0 dia.
3.0
2.205 dia.
Max. 4.5
7.2
39.5
80.0
66.0
25.4
3.150
2.598
3.071 dia.
.118
Max. .177
.283
1.555
3.150
2.598
1.000
Fail-safe type Latching type
Indicator
terminal
GND
6
J6
62
J2
1
2
COM
J1
COM
1
Coil terminal
2
3624
1
5
GND
Ind
(Bottm view)
1
COM
J5
J4
J2
4
MADE
IN
Serial No.
5
36
COM
J3
J6
J1
Coil
JAPAN
COM
6341
GND 52
Indicator terminal
Coil terminal
634152
*RESET (ALL)
1
(Bottm view)
Ind
GND
5
1
4263
2643
5
Serial No.
IN
MADE
JAPAN
COM
Coil
J1
J6
J3
J2
COM
J4
J5
R
Indicator
terminal
GND
6
J6
62
J2
1
2
COM
J1
COM
1
Coil terminal
*R
R
COM
6341
GND 52
Indicator terminal
Coil terminal
634152
Tolerance: ±0.3 ±.012
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
4. SP6T (with termination)
66.0
2.598
4-4.5 dia.
4-.177 dia.
80.0
3.150
78.0 dia.
3.071 dia.
7-5.08
7-.200
56.0 dia.
2.205 dia.
J5
J4
COM
J2 J3
J6
J1
Coil
COM
JAPA N
MADE
IN
Serial No.
5
34 62
3624
1
5
GND
Ind
(Bottom view)
1
J3
J5
J2
J1
J6
J4
7-SMA jack connector
6-termination
COM
80.066.025.4 3.1502.5981.000
Max. 4.5
Max. .177
39.5
1.555
7.2
.283
3.0
.118
Fail-safe type Latching type
Coil terminal
1
COM
J1COM
21
J2
26
J6
6
GND
Indicator
terminal
JAPAN
Coil
J1
J6
J3
COM
63
5
Serial No.
IN
MADE
4
J2
J4
J5
COM
1
(Bottom view)
Ind
GND
5
1
4263
2
COM
63
5
41
Indicator terminal
Coil terminal
GND 5
14263
2
R
Coil terminal
1
COM
J1COM
21
J2
26
J6
6
GND
Indicator
terminal
R
R
J5
J4
COM
J2 J3
J6
J1
Coil
COM
JAPAN
MADE
IN
Serial No.
5
34 62
3624
1
5
GND
Ind
(Bottom view)
1
COM
6341
Indicator terminal
Coil terminal
GND 52
634152
Tolerance: ±0.3 ±.012
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
RD (ARD)
ASCTB103E 201202-T
NOTES
1. For general cautions for use, please
refer to the “General Application
Guidelines”.
2. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 50 ms to set/reset the latching type
relay.
Please use the latching type for circuits
that are continually powered for long
periods of time.
3. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
4. Connection of coil indicator and
washing conditions
1) The connection of coil indicator
terminal shall be done by soldering.
Soldering conditions
Max. 260°C 500°F (solder temp) within
10sec (soldering time)
Max. 350°C 662°F (solder temp) within
3sec (soldering time)
2) This product is not sealed type,
therefore washing is not allowed.
5. Conditions for operation, transport
and storage conditions
1) Temperature:
–55 to +85°C –67 to +185°F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage:
4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C 32°F. This causes
problems such as sticking of movable
parts or operational time lags.
6) Low temperature, low humidity
environments.
The plastic may become brittle if the relay
is exposed to a low temperature, low
humidity environment for long periods of
time.
6. Other handling precautions.
1) The relay’s on/off service life is based
on standard test conditions (temperature:
15 to 35°C 59 to 95°F, humidity: 25 to
75%) specified in JIS C5442-1996. Life
will depend on many factors of your
system: coil drive circuit, type of load,
switching intervals, switching phase,
ambient conditions, to name a few.
2) Use the relay within specifications
such as coil rating, contact rating and on/
off service life. If used beyond limits, the
relay may overheat, generate smoke or
catch fire.
3) Be careful not to drop the relay. If
accidentally dropped, carefully check its
appearance and characteristics before
use.
4) Be careful to wire the relay correctly.
Otherwise, malfunction, overheat, fire or
other trouble may occur.
5) The latching type relay is shipped in
the reset position. But jolts during
transport or impacts during installation
can move it to the set position. It is,
therefore, advisable to build a circuit in
which the relay can be initialized (set and
reset) just after turning on the power.
6) If a relay stays on in a circuit for many
months or years at a time without being
activated, circuit design should be
reviewed so that the relay can remain
non-excited. A coil that receives current
all the time heats, which degrades
insulation earlier than expected. A
latching type relay is recommended for
such circuits.
7) For SMA connectors, we recommend
a torque of 0.90±0.1 N·m for installation,
which falls within the prescribed torque of
MIL-C-39012. Please be aware that
conditions might be different depending
on the connector materials and how it
interacts with surrounding materials.
8) Please do not use silicon based
substances such as silicon rubber, silicon
oil, silicon coatings and silicon fillings, in
the vicinity of the relay. Doing so may
cause volatile silicon gas to form which
may lead to contact failure due to the
adherence of silicon on the contacts
when they open and close in this
atmosphere.
9) Please note that when switching
contacts (latching type only), you must
apply reset (ALL) voltage and release all
contacts first. (SP6T type)
10) Do not use multiple contacts
simultaneously. (SP6T type)
11) The indicator terminal is the terminal
that indicates the operation status of the
MAIN contact.
12) For details about the drive method of
the latching with TTL driver type, please
refer to the RD coaxial switch catalog on
the website.
Tolerance range
(Avoid
condensation when
used at temperatures
higher than 0°C32°F)
(Avoid freezing when
used at temperatures
lower than 0°C32°F)
5
85
Temperature, °C°F
Humidity, %RH
–55 0 +85
–67 +32 +185