1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Features * Duplex LC Single Mode Transceiver * Small Form Factor Multi-sourced 2x5 Pin Package * Complies with IEEE 802.3 Gigabit Ethernet * 1270 nm to1610 nm Wavelength, CWDM DFB Laser * Single +3.3V Power Supply * LVPECL Differential Inputs and Outputs * LVTTL Signal Detection Output (C-1XX-1250C-FDFB-SLCX) * LVPECL Signal Detection Output (C-1XX-1250-FDFB-SLCX) * Temperature Range: 0 to 70 C * Class 1 Laser International Safety Standard IEC 825 compliant * Solderability to MIL-STD-883, Method 2003 * Pin Coating is Sn/Pb with minimum 2% Pb content * Flammability to UL94V0 * Humidity RH 5-85% (5-90% short term) to IEC 68-2-3 * Complies with Bellcore GR-468-CORE * Uncooled laser diode with MQW structure * 1.25 Gbps Ethernet Links application * 1.06 Gbps Fiber Channel application Absolute Maximum Rating Parameter Symbol Min. Max. Unit Power Supply Voltage Vcc 0 3.6 V Output Current Iout 0 30 mA Soldering Temperature - - 260 C Operating Temperature Topr 0 70 C Storage Temperature Tstg -40 85 C Note 10 seconds on leads only Recommended Operating Condition Parameter Symbol Min. Typ. Max. Unit Power Supply Voltage Vcc 3.1 3.3 3.5 V Operating Temperature (Case) Topr 0 - 70 C - 1250 - Mbps Data rate LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 1 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Transmitter Specifications Parameter Symbol Min Typical Max Unit Optical Transmit Power Po -5 Optical Transmit Power Po -3 Optical Transmit Power Po Output center Wavelength Notes - 0 dBm C-1XX-1250(C)-FDFB-SLC2 - +2 dBm C-1XX-1250(C)-FDFB-SLC3 0 - +5 dBm C-1XX-1250(C)-FDFB-SLC4 p-5.5 p p+7.5 nm p=1XX0 nm, C-1XX-1250(C)-FDFB-SLCX Optical Output Spectrum Width - - 1 nm -20 dB width Side Mode Suppression Ratio Sr 30 35 - dBm CW, Po=5mW Extinction Ratio ER 9 - - dB Output Eye Compliant with IEEE 802.3 Optical Rise Time tr - - 0.26 ns 20% to 80% Values Optical Fall Time tf - - 0.26 ns 20% to 80% Values RIN - - -120 dB/Hz TJ - - 0.27 ns Symbol Min Typical Max Unit Notes Power Supply Current ICC - - 180 mA Maximum current is specified at Vcc= Maximum @ maximum temperature Transmit Enable Voltage VEN 0 - 0.8 V VD 2.0 - Vcc V Data Input Current-Low IIL -200 - - A Data Input Current-High IIH - - 200 A Data Input Voltage-Low VIL-VCC -2.0 - -1.58 V Data Input Voltage-High VIH-VCC -1.1 - -0.74 V These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Symbol Min Typical Max Unit Notes - - - -22 dBm Maximum Input Power Pin -3 - - dBm Signal Detect-Asserted Pa - - -22 dBm Measured on transition: low to high Signal Detect-Deasserted Pd -38 - - dBm Measured on transition: high to low 1.0 - - dB 1100 - 1620 nm Relative Intensity Noise Total Jitter Measured with 27-1 PRBS Transmitter Specifications Parameter Electrical Transmit Disable Voltage Receiver Specifications Parameter Optical Sensitivity Signal Detect-Hysteresis Wavelength of Operation LUMINENTOIC.COM Measured with 27-1 PRBS, BER = 10 -12 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 2 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Receiver Specifications Parameter Symbol Min Typical Max Unit Note Electrical ICC - - 120 mA The current excludes the output load current Data Output Voltage-Low VOL -Vcc -2 - -1.58 V Data Output Voltage-High VOH- Vcc -1.1 - -0.74 V These outputs are compatible with 10K, 10KH and 100K ECL and LVPECL outputs Power Supply Current Signal Detect Output Voltage-Low VSDL-Vcc -2 - -1.58 V Signal Detect Output Voltage-High VSDH- Vcc -1.1 - -0.74 V Signal Detect Output Voltage-Low VSDL-Vcc - - 0.5 V Signal Detect Output Voltage-High VSDH- Vcc 2.0 - - V C-1XX-1250-FDFB-SLCX C-1XX-1250C-FDFB-SLCX Connection Diagram Legal Notice PIN Symbol Notes 1 RxGND Directly connect this pin to the receiver ground plane 2 TxVcc +3.3 V dc power for the receiver section 3 SD Active high on this indicates a received optical signal(LVPECL/LVTTL) 4 RD- Receiver Data Out Bar (LVPECL) 5 RD+ Receiver Dat Out (LVPECL) 6 TxVcc +3.3 V dc power for the transmitter section 7 TxGND Directly connect this pin to the transmitter ground plane 8 TxDIS Transmitter disable (LVTTL) 9 TD+ Transmitter Data In (LVPECL) 10 TD- Transmitter Data In Bar (LVPECL) Attaching Posts LUMINENTOIC.COM The attaching posts are at case potential and may be connected to chassis ground. They are isolated from circuit ground. 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 3 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Recommended Circuit Schematic PHY DEVICE TERMINATE AT TRANSCEIVER INPUTS Vcc(+3.3V) Z=50 TD- LVPECL 100 Z=50 1 2 TxGND TxVcc RD+ Rx RD- TD+ Tx 130 6 TxDIS 7 SD RxVcc 8 TD- 9 RxGND 10 3 4 TD+ 1H Vcc(+3.3V) C2 C3 130 C-1XX-1250-FDFB-SLCX 10F Vcc(+3.3V) 1H C1 5 RD+ Z=50 100 LVPECL RD- Vcc(+3.3V) Z=50 130 130 130 Z=50 SD 82 NOTE:C1=C2=C3=100nF TERMINATE AT DEVICE INPUTS Vcc(+3.3V) TERMINATE AT TRANSCEIVER INPUTS Z=50! TD- LVPECL 100! Z=50! 10 9 8 7 130! 6 1 3 TxDIS TxGND TxVcc RD- RD+ TD+ RxVcc 2 SD TD- Rx RxGND Printed Circuit Board Layout Consideration Tx 4 TD 1"H Vcc(+3.3V) C2 C3 130! C-1XX-1250C-FDFB-SLCX 10"F Vcc(+3.3V) 1"H C1 5 RD+ Z=50! LVPECL 100! RD- Z=50! 130! 130! Z=50! NOTE:C1=C2=C3=100nF SD TERMINATE AT DEVICE INPUTS The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc and Tx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 4 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Package Diagram 48.8+0 -0.2 10.16 (0.400) .000) (0.535) +(-(0.004) "3.6 +0 -0." 13.20 (0.520) (0.594) "5.08 .000) (1.921) +( -(0.008) 6.97 3.81 (0.150) 1.78 (0.039)(0.002) (0.070) 17.78 7.12 (0.280) 5.08 9.80 .000) (0.386) +(-(0.004) 9.50 0.50 (0.020) O1.00!0.05 9.8 +0 -0." (0.374) (0.447) "".36 10.50 (0.413) (0.386) "3.50 (0.531) (0.086) 3.95 (0.155) 2."8 (0.274) 6.25 (0.246) (0.200) (0.700) Units in mm(inch) Printed Circuit Board Layout Consideration A fiber-optic receiver employs a very high gain, wide bandwidth transimpedance amplifier. This amplifier detects and amplifies signals that are only tens of nA in amplitude when the receiver is operating near it's limit. Any unwanted signal current that couples into the receiver circuitry causes a decrease in the receiver's sensitivity and can also degrade the performance of the receiver's signal detect (SD) circuit. To minimize the coupling of unwanted noise into the receiver, careful attention must be given to the printed circuit board. At a minimum, a double-sided printed circuit board(PCB) with a large component side ground plane beneath the transceiver must be used. In applications that include many other high speed devices, a multi-layer PCB is highly recommended. This permits the placement of power and ground on separate layers, wich allows them to be isolated from the signal lines. Multilayer construction also permits the routing of signal traces away from high level, high speed sinal lines. To minimize the possibility of coupling noise into the receiver section, high level, high speed signals such as transmitter inputs and clock lines should be routed as far away as possible from the receiver pins. Noise that couples into the receiver through the power supply pins can also degrade performance. It is recommended that a pi filter be used in both transmitter and receiver power supplies. EMI and ESC Consideration LuminentOIC transceivers offer a metalized plastic case and a special chassis grounding clip. As shown in the drawing, this clip connects the module case to chassis ground then installs flush through the panel cutout. This way, the grounding clip brushes the edge of the cutout in order to make a proper contact. The use of a grounding clip also provides increased electrostatic protection and helps reduce radiated emission from the module or the host circuit board through the chassis faceplate. The attaching posts are at case potential and may be connected to chassis ground. They should not be connected to circuit ground. Plastic optical subassemblies are used to further reduce the possibility of radiated emission by eliminating the metal from the transmitter and receiver diode housings, which extend into connector space. By providing a non-metal receptacle for the optical cable ferrule, the gigabit speed RF electrical signal is isolated from the connector area thus preventing radiated energy leakage from these surfaces to the outside of the panel. LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 5 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Recommended Board Layout Hole Pattern DIMENSION IN MILLIMETER (INCHES) NOTES: 1.THIS FIGURE DESCRIBE THE RECOMMAND CIRCUIT BOARD LAYOUT FOR THE SFF TRANSCEIVER. 2.THE HATCHED AREAS ARE KEEP-OUT AREAS RESERVED FOR HOUSING STANDOFF. NO METAL TRACES OR GROUND CONNECTION IN KEEP-OUT AREAS. 3.THE MOUNTING STUDS SHOULD BE SOLDERED TO CHASSIS GROUND FOR MECHANICAL INTEGRITY. Recommended Panel mounting DIMENSION IN MILLIMETER (INCHES) LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 6 LUMNDS771-AUG2304 rev. A.0 1.25 Gbps Single Mode SFF LC Transceiver C-1XX-1250(C)-FDFB-SLCX Ordering Information Part numbering Definition: C - 1XX- 1250(C) - FDFB - S * 1XX = Wavelength 1XX0 nm XX=27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47, 49, 51, 53, 55, 57, 59, 61 LC TxPower Available Options: C-1XX-1250-FDFB-SLC2 C-1XX-1250-FDFB-SLC3 C-1XX-1250-FDFB-SLC4 C-1XX-1250C-FDFB-SLC2 C-1XX-1250C-FDFB-SLC3 C-1XX-1250C-FDFB-SLC4 * Communication protocol 1250= LVPECL SD output 1250C= LVTTL SD output * FDFB = +3.3V SFF Transceiver * Single mode fiber * Connector options * Tx Power range 2 = -5 to 0 dBm 3 = -3 to +2 dBm 4 = 0 to +5 dBm Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC's sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company's standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company's Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 7 LUMNDS771-AUG2304 rev. A.0