For details about certified products conforming to international standards, visit us at www.smcworld.com. Electro-pneumatic Regulator ITV1000/2000/3000 Standard Specifications ITV101 ITV201 ITV301 Model Right angle type Set pressure +0.1 MPa 0.2 MPa 1.0 MPa 0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa 24 VDC 10%, 12 to 15 VDC Power supply Power supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less Input impedance Note 3) Output signal (monitor output) JIS Symbol Output pressure (MPa) 0.005 MPa 0 Current consumption Current type Voltage type Preset input Current type Voltage type Preset input Note 2) Analog output Switch output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Minimum unit Ambient and fluid temperature Enclosure Rated pressure ITV10 ITV20 ITV30 Weight This range is outside of the control (output). 0 100 Input signal (%F.S.) Graph (1) Input/output characteristics chart ITV105 ITV205 ITV305 Minimum supply pressure Maximum supply pressure Set pressure range Note 1) Voltage Input signal Straight type ITV103 ITV203 ITV303 4 to 20 mA, 0 to 20 mA (Sink type) 0 to 5 VDC, 0 to 10 VDC 4 points 250 or less Approx. 6.5 k Approx. 2.7 k 1 to 5 VDC (Load impedance: 1 k or more) 4 to 20 mA (Sink type) (Load impedance: 250 or less) NPN open collector output: Max. 30 V, 30 mA PNP open collector output: Max. 30 mA Within 1% (full span) Within 0.5% (full span) Within 0.5% (full span) Within 0.2% (full span) Within 0.12% (full span)/C 3% (full span) MPa: 0.01, kgf/cm2: 0.01, bar: 0.01, PSI: 0.1 Note 4), kPa: 1 0 to 50C (with no condensation) IP65 Approx. 250 g (without options) Approx. 350 g (without options) Approx. 645 g (without options) Note 1) Please refer to "Graph (1)", relation to the differences between the set pressure and input. Additionally, refer to page 14-8-29 for the set pressure range by units of standard measured pressure. Additionally, refer to page 14-8-29 as maximum set pressure differs on unit of standard measure. Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required. Note 3) Select either analog output or switch output. Further, when switch output is selected, select either NPN output or PNP output. Note 4) The minimum unit for ITV205 is 1PSI. Note 5) The above characteristics are confined to the static state. When air is consumed on the output side, the pressure may fluctuate. How to Order ITV 3 0 1 0 Model 1000 2000 3000 1 2 3 Power supply voltage 0 1 24 VDC 12 to 15 VDC 0 1 2 1 3 5 Pressure display unit 0 1 2 3 4 - 0.1 MPa 0.5 MPa 0.9 MPa 2 3 4 5 Input signal Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type) Voltage 0 to 5 VDC Voltage 0 to 10 VDC Preset input Thread type - N T F Option Rc NPT NPTF G CE compliance Note 1) MPa kgf/cm2 bar PSI kPa - Q - CE compliant Please visit our SMC homepage: http://www.smcworld.com for the latest details on our CE compliant products. Option Cable connector type S L N Monitor output None (for preset input) 0 Analog output 1 to 5V DC 1 Switch output/NPN output 2 Switch output/PNP output 3 4 Analog output 4 to 20 mA (Sink type) 14-8-14 Q Pressure range Option Option S Straight type 3 m Right angle type 3 m Without cable connector Option Port size 1 2 3 4 1/8 (1000 type) 1/4 (1000, 2000, 3000 type) 3/8 (2000, 3000 type) 1/2 (3000 type) Bracket - B C Option Without bracket Flat bracket L-bracket Electro-pneumatic Regulator ITV1000/2000/3000 Series Standard specifications Combinations Combination possible Combination not possible ITV10 models are not applicable. SMC r Spacer ITV20 eL-bracket Standard specifications Approx. 133 1 Set pressure max. 0.5 MPa 3 Set pressure max. 0.9 MPa 5 Connection Rc 1/4 02 Connection Rc 3/8 03 Connection Rc 1/2 04 Acces- Bracket sories Bracket 178 wAFM30 REGULATOR ITV3000 ITV30 Optional specifications Approx. 189 Set pressure max. 0.1 MPa REGULATOR ITV2000 qAF30 Specifications Symbol Applicable model ITV20 ITV30 F.R.L. AV B AU C Connection NPT1/4 N02 Connection NPT3/8 N03 Connection NPT1/2 N04 Connection G 1/4 F02 Connection G 3/8 F03 Connection G 1/2 F04 AF AR IR VEX Approx. 243 Approx. 172 Modular Products and Accessory Combinations ITV10 models are not applicable. Applicable products and accessories qAF40 ITV20 ITV30 AF30 AF40 AFM30 AFM40 B310L B410L q Air filter w Mist separator e L-bracket r Spacer t Spacer with L-bracket (e + r) 234 AMR Applicable model ITV IC VBA Y30 Y40 Y30L Y40L VE wAFM40 VY1 G Accessory (Option)/Part No. INI-398-0-6 (Mounting thread is not included.) L-bracket 7 L-bracket Flat bracket 100 8 x o4.5 4 x o5.5 22 4 x o7 36 20 7 5 40 84 60 R3 . 5 2.3 50 40 36 22 22 14 TM-4DLX3HG4 36 40 Right angle type 3 m 70 TM-4DSX3HG4 x 8 x o4.5 4 x o5.5 1.6 Straight type 3 m 4 30 36 50 52 40 22 P3020114 (Mounting thread is not included.) Cable connector Flat bracket AL Dimensions 25 15 Part no. ITV10 ITV20 ITV30 12 Description PPA 14-8-15 Series ITV1000/2000/3000 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore, supply pressure passes through the air supply solenoid valve q and is applied to the pilot chamber e. The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u. Here, a correct operation functions until the output pressure is proportional to the input signal, making it possible to always obtain output pressure proportional to the input signal. Working Principle Diagram Pressure display Power supply i Control circuit Input signal Output signal Pressure display Power supply Input signal i Control circuit q Air supply solenoid valve Output signal w Exhaust solenoid valve EXH w Exhaust solenoid valve q Air supply solenoid valve u Pressure sensor r Diaphragm EXH u Pressure sensor e Pilot chamber r Diaphragm e Pilot chamber y Exhaust valve t Supply valve EXH SUP OUT t Supply valve SUP OUT EXH ITV1000 ITV2000, 3000 Block diagram Supply pressure q Air supply solenoid valve Input signal Output pressure i Control circuit r Diaphragm w Exhaust solenoid valve u Pressure sensor 14-8-16 Pilot valve Series Electro-pneumatic Regulator ITV1000/2000/3000 Series ITV101 Repeatability Hysteresis Linearity 1.0 0.08 0.06 0.04 0.02 0.00 0 25 50 75 100 1.0 Out 0.5 Return 0.0 -0.5 -1.0 0 25 Input signal (%F.S.) 75 100 Set point 0.0 -0.5 0.10 0.05 0 0.3 0.2 Set pressure (MPa) Set pressure (MPa) 0.5 0.1 F.R.L. -0.5 -1.0 0 AV 2 4 20 40 60 8 AU 10 80 AF AR 0.20 IR 0.15 VEX 0.10 AMR 0.05 ITV 0.00 0 100 Supply pressure: 0.2 MPa 0.25 20 Flow rate (l /min (ANR)) Supply pressure (MPa) 6 Relief Flow Characteristics 0.15 -1.0 0.0 0.0 Repetition Supply pressure: 0.2 MPa Flow Characteristics 1.0 Output deviation factor (%F.S.) 50 0.5 Input signal (%F.S.) Set pressure: 0.05 MPa Pressure Characteristics Output deviation factor (%F.S.) Output deviation factor (%F.S.) Set pressure (MPa) 0.10 40 60 80 Flow rate (l /min (ANR)) IC VBA VE Series ITV201 VY1 25 50 75 100 1.0 0.5 Out 0.0 Return -0.5 -1.0 0 Input signal (%F.S.) 100 75 0.5 AL 0.0 -0.5 -1.0 0 2 4 6 10 8 Repetition Supply pressure: 0.2 MPa Relief Flow Characteristics Supply pressure: 0.2 MPa 0.25 0.15 Set point 0.0 -0.5 0.1 0.2 Supply pressure (MPa) 0.3 Set pressure (MPa) 0.20 0.5 Set pressure (MPa) Output deviation factor (%F.S.) 50 Flow Characteristics 1.0 -1.0 0.0 25 PPA Input signal (%F.S.) Set pressure: 0.05 MPa Pressure Characteristics Output deviation factor (%F.S.) 1.0 Output deviation factor (%F.S.) Set pressure (MPa) 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 0 G Repeatability Hysteresis Linearity 0.10 0.05 0.15 0.10 0.05 0 200 400 Flow rate (l /min (ANR)) 600 0.00 0 200 400 600 800 Flow rate (l /min (ANR)) 14-8-17 ITV1000/2000/3000 Series Series ITV301 1.0 25 50 75 100 1.0 0.5 Out 0.0 Return -0.5 -1.0 0 Set pressure: 0.05 MPa 0.0 -0.5 -1.0 0 2 4 6 8 10 Repetition Supply pressure: 0.2 MPa Relief Flow Characteristics Supply pressure: 0.2 MPa 0.25 Set point 0.0 -0.5 0.1 0.2 Supply pressure (MPa) 0.3 Set pressure (MPa) 0.20 Set pressure (MPa) Output deviation factor (%F.S.) 100 75 0.15 0.5 14-8-18 50 Flow Characteristics 1.0 -1.0 0.0 25 0.5 Input signal (%F.S.) Input signal (%F.S.) Pressure Characteristics Output deviation factor (%F.S.) Output deviation factor (%F.S.) Set pressure (MPa) 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 0 Repeatability Hysteresis Linearity 0.10 0.05 0.00 0 500 1000 1500 Flow rate (l /min (ANR)) 2000 0.15 0.10 0.05 0.00 0 500 1000 1500 Flow rate (l /min (ANR)) 2000 Electro-pneumatic Regulator Series ITV1000/2000/3000 Series ITV103 0.4 0.3 0.2 0.1 25 50 75 100 Out 0.5 Return 0.0 -0.5 -1.0 0 25 Set pressure: 0.2 MPa 100 75 -1.0 0 AV 2 4 -0.5 0.4 0.3 0.2 0.1 0.0 0 0.8 0.6 8 AU 10 Supply pressure: 0.7 MPa 0.8 0.7 Set pressure (MPa) 0.0 Set pressure (MPa) Set point 6 Relief Flow Characteristics 0.5 0.5 0.4 F.R.L. -0.5 AF 0.6 -1.0 0.2 0.0 Repetition Supply pressure: 0.7 MPa Flow Characteristics 1.0 Output deviation factor (%F.S.) 50 0.5 Input signal (%F.S.) Input signal (%F.S.) Pressure Characteristics Output deviation factor (%F.S.) Output deviation factor (%F.S.) 0.5 Set pressure (MPa) 1.0 1.0 0.6 0.0 0 Repeatability Hysteresis Linearity IR 0.6 0.5 VEX 0.4 AMR 0.3 0.2 ITV 0.1 50 100 150 200 0.0 0 250 50 Flow rate (l /min (ANR)) Supply pressure (MPa) AR 100 150 200 IC Flow rate (l /min (ANR)) VBA VE Series ITV203 VY1 1.0 Output deviation factor (%F.S.) 0.4 0.3 0.2 0.1 0.0 0 25 50 75 100 0.5 Out 0.0 Return -0.5 -1.0 0 Input signal (%F.S.) Pressure Characteristics 25 50 100 75 Set pressure: 0.2 MPa Flow Characteristics Supply pressure: 0.7 MPa AL 0.0 -0.5 -1.0 0 2 4 Set pressure (MPa) 0.5 Set point 0.0 -0.5 Supply pressure (MPa) 0.8 0.4 0.3 0.2 0.0 0 8 10 Supply pressure: 0.7 MPa 0.8 0.7 0.1 0.6 6 Relief Flow Characteristics 0.6 0.4 0.5 Repetition 0.5 -1.0 0.2 PPA Input signal (%F.S.) 1.0 Output deviation factor (%F.S.) 1.0 Set pressure (MPa) Set pressure (MPa) 0.5 Output deviation factor (%F.S.) 0.6 G Repeatability Hysteresis Linearity 0.6 0.5 0.4 0.3 0.2 0.1 500 1000 1500 Flow rate (l /min (ANR)) 2000 0.0 0 500 1000 1500 2000 Flow rate (l /min (ANR)) 14-8-19 ITV1000/2000/3000 Series Series ITV303 0.6 Output deviation factor (%F.S.) 0.3 0.2 0.1 25 50 75 100 0.5 Out 0.0 Return -0.5 -1.0 0 Input signal (%F.S.) Pressure Characteristics 50 100 75 Set pressure: 0.2 MPa Flow Characteristics Supply pressure: 0.7 MPa Set point 0.0 -0.5 Set pressure (MPa) 0.5 -1.0 0 2 4 0.6 Supply pressure (MPa) 0.8 0.4 0.3 0.2 0.0 0 6 10 8 Supply pressure: 0.7 MPa 0.8 0.7 0.1 14-8-20 -0.5 Relief Flow Characteristics 0.6 0.4 0.0 Repetition 0.5 -1.0 0.2 0.5 Input signal (%F.S.) 1.0 Output deviation factor (%F.S.) 25 Set pressure (MPa) Set pressure (MPa) 0.4 1.0 Output deviation factor (%F.S.) 1.0 0.5 0.0 0 Repeatability Hysteresis Linearity 0.6 0.5 0.4 0.3 0.2 0.1 1000 2000 3000 4000 50006000 Flow rate (l /min (ANR)) 0.0 0 1000 2000 3000 4000 5000 Flow rate (l /min (ANR)) Electro-pneumatic Regulator Series ITV1000/2000/3000 Series ITV105 1.0 Set pressure (MPa) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 25 50 75 100 1.0 Out 0.5 0.0 Return -0.5 -1.0 0 25 50 100 Set point 0.0 -0.5 Supply pressure: 1.0 MPa Flow Characteristics Set pressure (MPa) 0.5 0.6 F.R.L. -0.5 -1.0 0 AV 2 4 0.8 1 1.0 0.9 0.8 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.0 0 1.2 6 8 AU 10 Supply pressure: 1.0 MPa Relief Flow Characteristics 1.0 0.9 0.1 -1.0 0.4 0.0 Repetition Set pressure (MPa) Set pressure: 0.4 MPa 1.0 Output deviation factor (%F.S.) 75 0.5 Input signal (%F.S.) Input signal (%F.S.) Pressure Characteristics Output deviation factor (%F.S.) Output deviation factor (%F.S.) 1.0 0.9 0.0 0 Repeatability Hysteresis Linearity 100 150 200 IR VEX 0.6 0.5 AMR 0.4 0.3 0.2 0.0 0 250 300 350 ITV 50 Flow rate (l /min (ANR)) Supply pressure (MPa) AR 0.7 0.1 50 AF 100 150 200 250 300 Flow rate (l /min (ANR)) IC VBA VE Series ITV205 VY1 0.5 0.4 0.3 0.2 0 25 50 100 75 Out 0.5 0.0 Return -0.5 -1.0 0 25 Input signal (%F.S.) Pressure Characteristics Set pressure: 0.4 MPa 75 Flow Characteristics 100 Supply pressure: 1.0 MPa 0 -0.25 -0.5 0 2 4 0.0 -0.5 1.0 Supply pressure (MPa) 1.2 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 6 8 10 Supply pressure: 1.0 MPa 1.0 0.9 0.8 Set pressure (MPa) Set point 0.8 AL Relief Flow Characteristics 0.8 0.5 0.6 0.25 Repetition 1.0 0.9 Set pressure (MPa) Output deviation factor (%F.S.) 50 PPA Input signal (%F.S.) 1.0 -1.0 0.4 Output deviation factor (%F.S.) 0.7 0.6 0.1 0.0 0.5 1.0 Output deviation factor (%F.S.) Set pressure (MPa) 1.0 0.9 0.8 G Repeatability Hysteresis Linearity 0.7 0.6 0.5 0.4 0.3 0.2 0.1 500 1000 1500 2000 2500 Flow rate (l /min (ANR)) 0.0 0 500 1000 1500 2000 2500 Flow rate (l /min (ANR)) 14-8-21 ITV1000/2000/3000 Series Series ITV305 0.6 0.5 0.4 0.3 50 100 75 0.0 Return -0.5 -1.0 0 Input signal (%F.S.) Pressure Characteristics Out 25 50 75 100 Set pressure: 0.4 MPa Flow Characteristics 1.0 Set pressure (MPa) 0.5 Set point 0.0 -0.5 Supply pressure: 1.0 MPa 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -1.0 0.4 0.6 0.8 1.0 Supply pressure (MPa) 14-8-22 0.5 0.0 -0.5 -1.0 0 Input signal (%F.S.) 1.2 0.0 2 4 6 8 10 Repetition Relief Flow Characteristics Set pressure (MPa) 25 0.5 Output deviation factor (%F.S.) Output deviation factor (%F.S.) Set pressure (MPa) 0.7 Output deviation factor (%F.S.) 1.0 1.0 1.0 0.9 0.8 0.2 0.1 0.0 0 Repeatability Hysteresis Linearity Supply pressure: 1.0 MPa 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1000 2000 3000 4000 5000 6000 7000 Flow rate (l /min (ANR)) 0.0 0 1000 2000 3000 4000 50006000 Flow rate (l /min (ANR)) Electro-pneumatic Regulator Series ITV1000/2000/3000 Dimensions ITV10 Note) Do not attempt to rotate, as the cable connector does not turn. Flat bracket Cable connector (4-wire) Straight type Cable connector (4-wire) Right angle type 50 F.R.L. (31) 4 x o7 Mounting hole AV SM C E P REGULATOR SMC E P REGULATOR AU 52 40 RESET SET ITV1000 ITV1000 UNLOCK AF LOCK AR Setting part IR 84 VEX 100 M12 x 1 Cable connection threads AMR (11) 12.5 ITV IC SM C E P REGULATOR VBA MPa Rc1/8 Exhaust port GY MADE IN JAPAN 71 Solenoid valve EXH G 19.5 OUT (2) VY1 2 OUT EXH (3) G PPA 12 SUP (1) VE 11 M3 x 0.5 Solenoid valve EXH ITV10 INPUT 0~10VDC OUTPUT 0.005~0.5MPa AL Flat bracket P3020114 (Optional) 40 2 x Rc1/8, 1/4 Port size 4 x M4 x 0.7 thread depth 6 mm through Mounting hole L-bracket G 2 OUT .5 7 25 15 R3 2.3 22 (10) 30 (7) 36 45 L-bracket INI-398-0-6 (Optional) 2 x Rc1/8, 1/4 SUP port, OUT port 14-8-23 Series ITV1000/2000/3000 Dimensions ITV20 Flat bracket Note) Do not attempt to rotate, as the cable connector does not turn. Cable connector (4-wire) Straight type Cable connector (4-wire) Right angle type 50 (31) 4 x o7 Mounting hole 40 SET REGULATOR SMC ITV2000 UNLOCK ITV2000 LOCK 84 100 M12 x 1 12.5 Cable connection threads (11) SMC REGULATOR ITV2000 93 M5 x 0.8 Solenoid valve EXH Rc1/4 Exhaust port Solenoid valve EXH 13.5 OUT SUP (1) EXH (3) 12 19 OUT (2) Flat bracket P3020114 (Optional) 36 2 x Rc1/4, 3/8 Port size 4 x M5 x 0.8 thread depth 6 mm through Mounting hole L-bracket 2 OUT 19 G .5 36 7 25 15 R3 2.3 (10) 30 (7) 36 14-8-24 REGULATOR 52 SMC RESET L-bracket INI-398-0-6 (Optional) 45 2 x Rc1/4, 3/8 SUP port, OUT port ITV1000/2000/3000 Series Electro-pneumatic Regulator Dimensions ITV30 Note) Do not attempt to rotate, as the cable connector does not turn. Flat bracket Cable connector (4-wire) Right angle type 52 4 x o7 Mounting hole (31) 40 Cable connector (4-wire) Straight type F.R.L. AV SMC REGULATOR SMC REGULATOR 100 84 SET UNLOCK 66 50 AU RESET ITV3000 ITV3000 AF LOCK AR IR 12.5 VEX M12 x 1 Cable connection threads (11) AMR ITV SMC E P REGULATOR IC ITV3000 M5 x 0.8 VBA Solenoid valve EXH Solenoid valve EXH 114 VE VY1 35.7 Rc1/2 Exhaust port G G 2 EXH (3) 8 SUP (2) PPA AL 12 22 SUP (1) OUT 36 Flat bracket P3020114 (Optional) 2 x Rc1/4, 3/8, 1/2 Port size 4 x M5 x 0.8 thread depth 6 mm through Mounting hole L-bracket G OUT .5 7 25 15 R3 25 30 22 2 (10) 30 (7) 36 L-bracket INI-398-0-6 (Optional) 36 2 x Rc1/4, 3/8, 1/2 SUP port, OUT port 2.3 45 14-8-25 Series ITV1000/2000/3000 Made to Order Specifications: Please contact SMC regarding detailed dimensions, specifications and delivery times. 1 Ozone Resistant 4 Digital Input Type -X93 Fluoro rubber is used for the rubber parts of seals. Parallel input type with digital 10 bit. 80 ITV10 0 4 0 X93 ITV20 0 4 0 X93 ITV30 0 4 0 X93 Standard model number Ozone resistant Digital input type 2 Reverse Type -X102 In compliance with input, inverse proportional pressure is displayed. ITV10 X102 ITV20 X102 ITV30 X102 Note 1) in part number is the same model no. for the standard products. 5 DeviceNet Compliant -X80 It is conforming to DeviceNet. Reverse type Output pressure (MPa) Rated pressure 0 100 Input/output characteristics chart Note 1) in part number is the same model no. for the standard products. Note 2) Except for preset input type. 3 16 Points Preset Input Type -X81 Able to control 16-point-pressure by 4 bit switching input ITV10 0 4 X81 ITV20 0 4 X81 ITV30 0 4 X81 16 points preset type 14-8-26 4 0 X80 ITV20 0 4 0 X80 ITV30 0 4 0 X80 Note 1) in part number is the same model no. for the standard products. Note 2) The pressure is not indicated. Input signal (%F.S.) Note 1) in part number is the same model no. for the standard products. Note 2) Monitor output is switch output type only. 0 DeviceNet compliant This range is outside of the control (output). 0.005 MPa 0 ITV10 Series ITV1000/2000/3000 Made to Order Specifications: Please contact SMC regarding detailed dimensions, specifications and delivery times. 6 Manifold Specifications (Except Series ITV3000) 2 through 8 station manifold. How to Order Manifold IITV20 How to Order Manifold Assembly 02 5 F.R.L. Example Valve stations 2 2 stations 8 8 stations Electro-pneumatic regulator 02 03 P398020-13 UN LO CK SMC OUT port size ITV1000/2000 AV Blanking plate assembly ITV1030-311S-X26 Electro-pneumatic regulator RE SE T SE T LO CK E PREGUL ITV2050-212S-X26 ATOR 1/4 3/8 UN LO CK MP a 2 OU T SMC PREGUL AF RE SE T SE T LO CK E AU AR ATOR G Connection thread type - N F MP a IR PT NPT PF SU VEX 2 Manifold base (3 stations) IITV20-02-3 ........................1 set (3 station manifold base part no.) ITV2030-311S-X26 ............1 set (Electro-pneumatic regulator part no.) Note 2) P398020-13 ..................... 1 set (Blanking plate assembly part no.) ITV2050-212S-X26 ............1 set (Electro-pneumatic regulator part no.) Note 2) 1 AMR 2 IITV20-02-3 ITV 3 The is the symbol for mounting. Add the symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base. IC Sta tio ns Note 1) Note 1) Electro-pneumatic regulators are counted starting from station 1 on the left side with the OUT ports in front. Note 2) The port size for mounted electro-pneumatic regulators is Rc1/8 (ITV1000), Rc1/4 (ITV2000) only. Note 3) When there is a large number of stations, use piping with the largest possible inside diameter for the supply side, such as steel piping. Note 4) The use of the straight type cable connector is recommended. To mount right angle type, be certain to check that no possible interference occurs. Note 5) When mounting a blanking plate and the regulator with different pressure set, please inform SMC of the order of a manifold station beside a purchase order. Note) Refer to the table below for possible mixed combination. ITV101 ITV103 ITV105 ITV201 ITV203 ITV205 Model P G ITV101 ITV103 ITV105 ITV201 ITV203 ITV205 7 High-Speed Response Time Specifications -X88 Pressure response with no load is approx. 0.1 sec. ITV 2 0 1 0 0 1 2 S X88 High-speed response time specifications Model 1000 type 2000 type 1 2 Pressure range 1 3 5 Power supply voltage 0 1 24 VDC 12 to 15 VDC 0.1 MPa 0.5 MPa 0.9 MPa Pressure display unit - Input signal 0 1 2 3 MPa kgf/cm2 bar PSI kPa 2 3 4 5 Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type) Voltage 0 to 5 VDC Voltage 0 to 10 VDC Cable connector type S L N Monitor output 1 2 3 4 Analog output 1 to 5V DC Switch output/NPN output Switch output/PNP output Analog output 4 to 20 mA (Sink type) Thread type - N T F Rc NPT NPTF G Port size 1 2 3 1/8 (1000 type) 1/4 (1000, 2000 type) 3/8 (2000 type) Straight type 3 m Right angle type 3 m Without cable connector Bracket - B C Without bracket Flat bracket L-bracket 14-8-27 VBA VE VY1 G PPA AL Series ITV1000/2000/3000 Specific Product Precautions 1 Be sure to read before handling. Operating Environment Warning Caution 1. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. 2. Consult SMC when used in power plants, or if instrumentation related. Air Supply Caution 1. Install an air filter near this product on the supply side. Select a filtration degree of 5 m or less. 2. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc. 3. If large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to Best Pneumatics Vol. 16. Handling Caution 1. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment. 2. If electric power is shut off while pressure is being applied, pressure will be retained on the output side. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc. 3. If power to this product is cut off due to a power failure, etc. when it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out. 14-8-28 Handling 4. If supply pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off. 5. In this product, the output side pressure cannot be completely relieved within the range of 0.005 MPa or less. If it is desired to reduce the pressure completely to 0 MPa, install a 3 way valve or other device on the output side to exhaust the pressure. 6. This product is adjusted for each specification at the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can lead to malfunction. 7. The optional cable connector is a 4 wire type. When the monitor output (analog output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction. 8. Please note that the right angle cable does not rotate and is limited to only one entry direction. 9. Take the following steps to avoid malfunction due to noise. 1) Remove power supply noise during operation by installing a line filter, etc. in the AC power line. 2) For avoiding the influence of noise install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. 3) Be sure to implement protective measures against load surge for induction loads (solenoid valves, relays, etc.). 4) Install or remove the connector after shutting off the power supply to avoid the influence of chattering of the power supply. 10. Due to the large volume of the output side, a loud exhaust noise will be produced when being used for the purpose of a relief function. Therefore, install a silencer (SMC Series AN200 or AN400) on the exhaust port (EXH port). The port sizes are Rc1/8, Rc1/4 and Rc1/2. 11. Specifications on page 1 is in case of static environment. Pressure may fluctuate when air is consumed at the output side. 12. For details on the handling of this product, refer to the instruction manual which is included with the product. Series ITV1000/2000/3000 Specific Product Precautions 2 Be sure to read before handling. Wiring Caution Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Monitor output wiring diagram F.R.L. Analog output, voltage type AV Brown Blue AU White Monitor output current AF Black Brown Blue White Black 3: (Blue) 1: (Brown) 4: (Black) 2: (White) AR Note) Switch output, NPN type Body IR RESET Brown Current signal type Voltage signal type 1 Brown Power supply 2 White Input signal 3 Blue GND (COMMON) 4 Black Monitor output Load Preset input type 1 Brown Power supply 2 White Input signal 3 Blue GND (COMMON) 4 Black Monitor output ITV IC Switch output, PNP type VBA Brown VE Blue Wiring diagram Current signal type Load Voltage signal type White VY1 Black Brown Brown G Blue Blue Vs White White Black A AMR White Black Note) A right angle type cable is also available. The entry direction for the right angle type connector is to the left (SUP port side). Never turn the connector as it is not designed to turn. Vs VEX Blue Vin PPA Analog output, current type (sink type) Black AL Brown Vs: Power supply 24 VDC 12 to 15 VDC A : Input signal 4 to 20 mADC 0 to 20 mADC Vs : Power supply 24 VDC 12 to 15 VDC Vin: Input signal 0 to 5 VDC 0 to 10 VDC Blue Monitor output current White Black Preset input type Brown When 30 mA DC or more is applied, detecting device for overcurrent starts activating and then emits an error signal. (Error number "5") Blue Vs S1 White S2 Black Set Pressure Range Vs: Power supply 24 VDC 12 to 15 VDC One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 OFF ON S2 OFF OFF Preset pressure P1 P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0 MPa. The regulating pressure range, by unit of standard measured pressure, is shown in the table below. Regulating pressure range, by unit of standard measured pressure Regulating pressure range Unit ITV01 ITV03 ITV05 MPa kgf/cm2 bar PSI kPa 0.005 to 0.1 0.05 to 1 0.05 to 1 0.7 to 15 5 to 100 0.005 to 0.5 0.05 to 5 0.05 to 5 0.7 to 70 5 to 500 0.005 to 0.9 0.05 to 9 0.05 to 9 0.7 to 130 5 to 900 14-8-29