Part #:
Revision: ZA120LACT
B
Mallory Sonalert Products,Inc.
Sales Outl ine Drawing
Sound Level Category
Mode of Operation
Continuous
Specifications:
Approved with use of included gasket.
Weight (Typical)
Recommended hole size is 22.5 mm. Thread front will fit standard 22.5mm hole.
Current Draw
40mA MAX
Storage Temperature
Loud
3300 ± 500 Hz
Housing Material
6/6 Nylon, Color: Black
Frequency
Loudness @ 2 FT
85 to 95 dB(A) Typ.
48 to 120 VAC/DC
Voltage Rating
Please contact factory.
NEMA 3R,4X, & 12
-30° to +50° C
-40° to +55° C
Used to attach part to panel. The max recommended torque is 10 in-lbs.
28 g
Operating Temperature
Panel Mounting
Knurled Nut
Options
ROHS Compl iant
4411 South High School Road, Indianapolis, Indiana 46241 U.S.A · Phone: (317) 612-1000 Fax: (317) 612-1010
www.mallory-sonalert.com
Dimensions:
Inches (mm)
1.210 [30.74]
M22 x 1.5 Thread
<0.86 Maj. Dia.
0.524 [13.31]
Gasket
Knurl nut
1.710 [43.44]
+-
ZA Series- 22mm Panel Alarms
Mounting Instructions:
Panel Hole Size: 22.5 mm with Keyway
Maximum Panel Thickness: 12.7 mm (0.5 in)
Maximum Nut Torque: 10 in-lbs (1.13 n-m)
Electrical Connection:
Wire Strip Length: 6.5 mm (0.256 in)
Wire Size: 30 to 16 AWG
Maximum Screw Torque: 2 in-lbs (0.226 n-m)
DC ONLY
AC/DC
Panel Hole Cut Out
Before Code
Date 1223 3
After Code
Date 1223 3
Before Code
Date 1223 3
After Code
Date 1223 3
ZA Series- 22mm Panel Alarms
Certifications:
RoHS; cUL; NEMA 3R/4X/12; IP-66; CSA 22.2 No. 94
o Included gasket must be used to maintain NEMA 3R/4X/12 ratings.
cUL Yellow Card:
UL Online Certifications Directory
UCST8.S1290
Audible Signal Appliances, General Signal Certified for Canada - Component
Audible-signal Appliances, General Signal Certified for Canada - Component
MALLORY SONALERT PRODUCTS INC
S1290
4411 S HIGH SCHOOL RD
INDIANAPOLIS, IN 46241 USA
Audible tone generators, ZA aaa b c ddd (f9)
(f9) - Must be used with neoprene gasket type 4216-S to maintain enclosure NEMA Type Ratings 3R, 4X and 12.
aaa - Indicates voltage rating. May be 016, 028, 048 or 120.
b - Indicates sound level. May be L, M or S.
c - Indicates voltage type. May be A or D.
ddd - Indicates Sound Function. May be any combination of letters A through Z and/or numbers 0 through 9.
Marking: Company name or tradename "Mallory" , "Sonalert" , model designation and Recognized Component Mark for
Canada, .
Last Updated on 2012-02-03
© 2012 UL LLC
Reprinted from the Online Certifications Directory with permission from UL
ZA Series- 22mm Panel Alarms
Sound Level vs Distance:
The ZA Series of 22mm alarms measures sound level at 2 feet. Since sound level drops
over distance, the above chart lists the equivalent sound levels at various distances.
For example, if the Mallory part is in the LOUD sound level category, it has a sound
level of 85 to 95 dB at 2 feet. At 10 cm, the sound level would measure 100 to 110 dB.
Packaging:
Standard orders are bulk packed.
For individual box packaging, add one of the following part numbers to order:
Accessories:
Various
Measurement
Distances
ZA Series Sound Level Category
Loud
85 95 dB @ 2 ft
Medium
75 85 dB @ 2 ft
Soft
65 85 dB @ 2 ft
10 cm (4 in)
100 to 110 dB
90 to 100 dB
80 to 90 dB
30 cm (1 ft)
91 to 101 dB
81 to 91 dB
71 to 81 dB
1 Meter
82 to 92 dB
72 to 82 dB
62 to 72 dB
10 ft
71 to 81 dB
61 to 71 dB
51 to 61 dB
Part Number
Description
BOX
Individual box- no label
BOXLABEL
Individual box with label
Part Number
Description
Notes
ACC06
Replacement NEMA Gasket
Gasket comes with part
BOX
Individual box- no label
Must be ordered with part
BOXLABEL
Individual box with label
Must be ordered with part
KNT1-01
Replacement Nut
Nut comes with part