OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Hallogic Hall-effect Sensors
OH090U, OH180U, OH360U
OHN3000 Series, OHS3000 Series
OHN3100 Series, OHS3100 Series
OPTE K Te chnology I nc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A .1 06/05
Page 2 of 9
Notes:
(1) South pole facing symbolized surface.
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
BOP Magnetic Operate Point(1) 70 180 290 Gauss
BRP Magnetic Release Point 0 140 230 Gauss
BH Magnetic Hysteresis 20 40 120 Gauss
Icc Supply Current - 6 9 mA Vcc = 24 V, Output Off
VOL Output Saturation Voltage - 100 300 mV Vcc = 4.5 V, IOL = 20 mA, B ≥ 290 Gauss
IOH Output Leakage Current - 0.5 10.0 µA Vcc = 24 V, VOUT = 24 V, B ≤ 0 Gauss
tr Output Rise Time - 0.21 1.00 µs
RL = 820 Ω, CL = 20 pF, Vcc = 14 V
tf Output Fall Time - 0.10 1.00 µs
OH180U Uni-Polar
OH090U Uni-Polar
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
BOP Magnetic Operate Point(1) 0 90 180 Gauss
BRP Magnetic Release Point -100 65 100 Gauss
BH Magnetic Hysteresis 10 25 100 Gauss
Icc Supply Current - 6 9 mA Vcc = 24 V, Output Off
VOL Output Saturation Voltage - 100 300 mV Vcc = 4.5 V, IOL = 20 mA, B ≥ 180 Gauss
IOH Output Leakage Current - 0.5 10.0 µA Vcc = 24 V, VOUT = 24 V, B ≤ -100 Gauss
tr Output Rise Time - 0.21 1.00 µs
RL = 820 Ω, CL = 20 pF, Vcc = 14 V
tf Output Fall Time - 0.10 1.00 µs
Electrical Characteristics (Vcc = 4.5 V to 24 V, TA = 25° C unless otherwise noted)
Absolut e Maxi mum Ratings (TA=25°C unless otherwise noted)
Supply Voltage, Vcc 25 V
Storage Temperature Range, TS -65°C to +160°C
Operating Temperature Range, TA OHN30_ _U
OHS30_ _U
OH090/180/360U
-20°C to +85°C
-40°C to +125°C
-40°C to +150°C
Lead Soldering Temperature (1/8 in. (3.2 mm) from case for 5 sec. with soldering iron) 260°C(1)
Output ON Current, ISINK 25 mA
Output OFF Voltage, VOUT 25 V
Magnetic Flux Density, B Unlimited